Determination of k 0-values for some elements in neutron capture gamma-ray for prompt gamma activation analysis

被引:3
|
作者
Hamid, A. [1 ]
机构
[1] Atom Energy Author, Hot Labs Ctr, Dept Radiated Pollut, Cairo 13759, Egypt
关键词
k(0)-PGNAA technique; Prompt gamma-ray; Prompt k(0)-factors; Neutron flux ratio; Monostandard method; K(0)-FACTORS; SAMPLES;
D O I
10.1007/s10967-011-1388-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Exploration and modification of data for k (0)-PGAA (prompt gamma-ray activation analysis) values used as standards for k (0) standardization are needed. An integrated system has been installed and calibrated in Hot Laboratories Center for PGAA, using Cf-252 isotopic neutron source with neutron flux of 6.16E8 n/cm(2) s. The prompt k (0)-factors of about 12 elements were determined versus the 1951.1 keV gamma-ray of the Cl-35, as well as analyzing crude oil and oil product samples. The concentrations of the elements in crude oil H, B, Mg, Al, Na, Si, P, S, Cl, V and Cd were 1.18E5, 0.084, 5.48E2, 8.45E2 4.88E2, 1.62E2, 3.72E2, 8.2, 144.3, 393 and 209.2 ppm while in oil product samples were 1.32E5, 5.87, 4.56E2, 4.22E2, 7.16E3, 699, 157, 8.74, 492.3, 61 and 198.2 ppm. Validation of the k (0)-PGAA was applied in analyzing standard IAEA reference material (soil-7) which give good agreement with the literature data. The Cf-252 neutron beam in radiation position was characterized by the cadmium-ratio method, and found that the cadmium ratio (f), was 160.
引用
收藏
页码:623 / 628
页数:6
相关论文
共 50 条
  • [1] Determination of k0-values for some elements in neutron capture gamma-ray for prompt gamma activation analysis
    A. Hamid
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2012, 291 : 623 - 628
  • [2] Erratum to: Determination of k0-values for some elements in neutron capture gamma-ray for prompt gamma activation analysis
    Ashraf Hamid
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2014, 299 : 2043 - 2043
  • [3] Determination of k0-values for some elements in neutron capture gamma-ray for prompt gamma activation analysis (vol 291, pg 623, 2012)
    Hamid, Ashraf
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 299 (03) : 2043 - 2043
  • [4] Measurement of k0-factors in prompt gamma-ray neutron activation analysis
    Acharya, RN
    Sudarshan, K
    Nair, AGC
    Scindia, YM
    Goswami, A
    Reddy, AVR
    Manohar, SB
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2001, 250 (02) : 303 - 307
  • [5] Measurement of k0-Factors in Prompt Gamma-Ray Neutron Activation Analysis
    R.N. Acharya
    K. Sudarshan
    A.G.C. Nair
    Y.M. Scindia
    A. Goswami
    A.V.R. Reddy
    S.B. Manohar
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2001, 250 : 303 - 307
  • [6] Neutron Capture Prompt Gamma-Ray Activation Analysis of Meat Homogenates
    D. L. Anderson
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2000, 244 : 225 - 229
  • [7] Neutron capture prompt gamma-ray activation analysis of meat homogenates
    Anderson, DL
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 244 (01) : 225 - 229
  • [8] The k0-method in cold-neutron prompt gamma-ray activation analysis
    S. Baechler
    P. Kudejova
    J. Jolie
    J.-L. Schenker
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2003, 256 : 239 - 245
  • [9] The k0-method in cold-neutron prompt gamma-ray activation analysis
    Baechler, S
    Kudejova, P
    Jolie, J
    Schenker, JL
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 256 (02) : 239 - 245
  • [10] Analysis of alloys by prompt gamma-ray neutron activation
    Nair, AGC
    Sudarshan, K
    Raje, N
    Reddy, AVR
    Manohar, SB
    Goswami, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 516 (01): : 143 - 148