Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence

被引:5
|
作者
Gambarini, Gianluca [1 ]
Plotino, Gianluca [1 ]
Piasecki, Lucila [2 ]
Al-Sudani, Dina [3 ]
Testarelli, Luca [1 ]
Sannino, Gianpaolo [4 ]
机构
[1] Sapienza Univ Rome, Endodont Unit, Dept Oral & Maxillofacial Sci, Rome, Italy
[2] PUC Univ, Curitiba, Parana, Brazil
[3] King Saud Univ, Coll Dent, Dept Restorat Dent Sci, Riyadh, Saudi Arabia
[4] Univ Rome II, Tor Vergata, Italy
关键词
nickel-titanium; brushing action; deformations; cyclic fatigue;
D O I
10.11138/ads/2015.6.1.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim. To compare the effect of brushing motion on torsional and cyclic fatigue resistance of TF Adaptive instruments after clinical use. Methods. 20 packs of TFA small sequence (SybronEndo, Orange, CA, USA) were used for this study and divided into two groups. Each instrument prepared one resin tooth, consisting in 4 canals with a complex anatomy. In group A, no brushing motion was performed. In group B, after the green instrument reached the working length, brushing motion with circumferential filing was performed for 15 seconds in each canal (overall 1 minute). All the instruments were then subjected to cyclic fatigue test and mean values and standard deviation for time to fracture were evaluated. Data were subjected to one-way analysis of variance and Bonferroni t-test procedure with a significance set at P < 0.05. Results. No instruments were broken during preparation of root canals. Two TF Adaptive green and 5 yellow showed unwinding after intracanal clinical use. No statistically significant differences were found between green instruments of both groups (P > 0.05), while a statistically significant difference was found between the yellow instruments (P < 0.05), with group B showing an higher resistance to cyclic fatigue. Conclusions. A prolonged passive brushing motion did not adversely affected mechanical resistance of the instrument used for this purpose. Resistance to both deformations and cyclic fatigue of the second instrument within the TFA small sequence was enhanced by the coronal flaring provided by the brushing action of the first instrument used.
引用
收藏
页码:6 / 9
页数:4
相关论文
共 50 条
  • [31] Cyclic Fatigue Resistance of Rotary and Reciprocating Nickel-Titanium Instruments Subjected to Static and Dynamic Tests
    Thu, Myint
    Ebihara, Arata
    Maki, Keiichiro
    Miki, Nishijo
    Okiji, Takashi
    JOURNAL OF ENDODONTICS, 2020, 46 (11) : 1752 - 1757
  • [32] Cyclic Fatigue Resistance of Three Different Nickel-Titanium Instruments after Immersion in Sodium Hypochlorite
    Pedulla, Eugenio
    Grande, Nicola M.
    Plotino, Gianluca
    Pappalardo, Alfio
    Rapisarda, Ernesto
    JOURNAL OF ENDODONTICS, 2011, 37 (08) : 1139 - 1142
  • [33] The Effect of Temperature on Cyclic Fatigue of Nickel-titanium Rotary Endodontic Instruments
    Dosanjh, Amandeep
    Paurazas, Susan
    Askar, Mazin
    JOURNAL OF ENDODONTICS, 2017, 43 (05) : 823 - 826
  • [34] Cyclic fatigue resistance of two reciprocating nickel-titanium instruments after immersion in sodium hypochlorite
    Pedulla, E.
    Grande, N. M.
    Plotino, G.
    Palermo, F.
    Gambarini, G.
    Rapisarda, E.
    INTERNATIONAL ENDODONTIC JOURNAL, 2013, 46 (02) : 155 - 159
  • [35] Comparison of Cyclic Fatigue Resistance of Three Different Rotary Nickel-Titanium Instruments Designed for Retreatment
    Inan, Ugur
    Aydin, Cumhur
    JOURNAL OF ENDODONTICS, 2012, 38 (01) : 108 - 111
  • [36] Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments
    Mize, SB
    Clement, DJ
    Pruett, JP
    Carnes, DL
    JOURNAL OF ENDODONTICS, 1998, 24 (12) : 843 - 847
  • [37] Cyclic Fatigue Testing and Metallographic Analysis of Nickel-Titanium Rotary Instruments
    Pirani, Chiara
    Cirulli, Pier Paolo
    Chersoni, Stefano
    Micele, Lorenzo
    Ruggeri, Oddone
    Prati, Carlo
    JOURNAL OF ENDODONTICS, 2011, 37 (07) : 1013 - 1016
  • [38] Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency
    Bui, Tung B.
    Mitchell, John C.
    Baumgartner, J. Craig
    JOURNAL OF ENDODONTICS, 2008, 34 (02) : 190 - 193
  • [39] Metallurgical analysis and fatigue resistance of WaveOne and ProTaper Nickel-Titanium instruments
    Pirani, Chiara
    Ruggeri, Oddone
    Cirulli, Pier Paolo
    Pelliccioni, Gian Andrea
    Gandolfi, Maria Giovanna
    Prati, Carlo
    ODONTOLOGY, 2014, 102 (02) : 211 - 216
  • [40] Cyclic fatigue resistance of XP-endo Shaper compared with different nickel-titanium alloy instruments
    Amr Elnaghy
    Shaymaa Elsaka
    Clinical Oral Investigations, 2018, 22 : 1433 - 1437