l Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy

被引:14
|
作者
Kim, Kyung Mi [1 ]
Gwak, Mi Sook [2 ]
Choi, Soo Joo [2 ]
Kim, Myung Hee [2 ]
Park, Mi Hye [2 ]
Heo, Burn Young [2 ]
机构
[1] Hallym Univ Dongtan Sacred Heart Hosp, Dept Anesthesiol & Pain Med, Hwaseong, South Korea
[2] Sungkyunkwan Univ, Samsung Med Ctr, Sch Med, Seoul, South Korea
关键词
Arterial blood pressure; Cardiac output; Carotid endarterectomy; Fluid therapy; Stroke volume;
D O I
10.4097/kjae.2013.65.3.237
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: During carotid endarterectomy (CEA), hemodynamic stability and adequate fluid management are crucial to prevent perioperative cerebral stroke, myocardial infarction and hyperperfusion syndrome. Both pulse pressure variation (PPV) and stroke volume variation (SVV), dynamic preload indices derived from the arterial waveform, are increasingly advocated as predictors of fluid responsiveness in mechanically ventilated patients. The aim of this study was to evaluate the accuracy of PPV and SVV for predicting fluid responsiveness in patients undergoing CEA. Methods: Twenty seven patients undergoing CEA were enrolled in this study. PPV, SVV and cardiac output (CO) were measured before and after fluid loading of 500 ml of hydroxyethyl starch solution. Fluid responsiveness was defined as an increase in CO >= 15%. The ability of PPV and SVV to predict fluid responsiveness was assessed using receiver operating characteristic (ROC) analysis. Results: Both PPV and SVV measured before fluid loading are associated with changes in CO caused by fluid expansion. The ROC analysis showed that PPV and SVV predicted response to volume loading (area under the ROC curve = 0.854 and 0.841, respectively, P < 0.05). A PPV >= 9.5% identified responders (Rs) with a sensitivity of 71.4% and a specificity of 90.9%, and a SVV >= 7.5% identified Rs with a sensitivity of 92.9% and a specificity of 63.6%. Conclusions: Both PPV and SVV values before volume loading are associated with increased CO in response to volume expansion. Therefore, PPV and SVV are useful predictors of fluid responsiveness in patients undergoing CEA.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 50 条
  • [31] A comparative study of pulse pressure variation, stroke volume variation and central venous pressure in patients undergoing kidney transplantation
    Kim, Kyung Mi
    Kim, Gaab Soo
    Han, Minsoo
    SINGAPORE MEDICAL JOURNAL, 2022, 63 (12) : 731 - 739
  • [32] Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing One-Lung Ventilation
    Suehiro, Koichi
    Okutani, Ryu
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (05) : 772 - 775
  • [33] Stroke volume variation as a predictor of fluid responsiveness for cardiac output in patients undergoing cardiac surgery
    Klinzing, S
    Seeber, P
    Schiergens, V
    Sakka, S
    Reinhart, K
    Meier-Hellmann, A
    CRITICAL CARE MEDICINE, 2001, 29 (12) : A56 - A56
  • [34] Prediction of Fluid Responsiveness by Stroke Volume Variation in Children Undergoing Fontan Operation
    Song, Yun'an
    Hou, Huiyan
    Bai, Jie
    Gu, Hongbin
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [35] Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
    Messina, Antonio
    Caporale, Mariagiovanna
    Calabro, Lorenzo
    Lionetti, Giulia
    Bono, Daniele
    Matronola, Guia Margherita
    Brunati, Andrea
    Frassanito, Luciano
    Morenghi, Emanuela
    Antonelli, Massimo
    Chew, Michelle S.
    Cecconi, Maurizio
    CRITICAL CARE, 2023, 27 (01)
  • [36] Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
    Antonio Messina
    Mariagiovanna Caporale
    Lorenzo Calabrò
    Giulia Lionetti
    Daniele Bono
    Guia Margherita Matronola
    Andrea Brunati
    Luciano Frassanito
    Emanuela Morenghi
    Massimo Antonelli
    Michelle S. Chew
    Maurizio Cecconi
    Critical Care, 27
  • [37] The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery
    Wyffels, P. A. H.
    Sergeant, P.
    Wouters, P. F.
    ANAESTHESIA, 2010, 65 (07) : 704 - 709
  • [38] Relationship of stroke volume variation, pulse pressure variation and global end-diastolic volume in patients undergoing brain surgery
    A Rieß
    S Wolf
    C Lumenta
    L Schürer
    P Friederich
    Critical Care, 14 (Suppl 1):
  • [39] Ability of a New Smartphone Pulse Pressure Variation and Cardiac Output Application to Predict Fluid Responsiveness in Patients Undergoing Cardiac Surgery
    Joosten, Alexandre
    Boudart, Celine
    Vincent, Jean-Louis
    Eynden, Frederic Vanden
    Barvais, Luc
    Van Obbergh, Luc
    Rinehart, Joseph
    Desebbe, Olivier
    ANESTHESIA AND ANALGESIA, 2019, 128 (06): : 1145 - 1151
  • [40] Prediction of fluid responsiveness in septic shock patients: comparing automated pulse pressure variation by IntelliVue MP monitor and stroke volume variation by FloTrac™/Vigileo™
    B Khwannimit
    R Bhurayanontachai
    Critical Care, 15 (Suppl 1):