SPECTRUM ANALYSIS OF RECORDED MAGNETIZATION USING MAGNETIC FORCE MICROSCOPY

被引:15
|
作者
HONDA, Y
INABA, N
TOMIYAMA, F
YAMAMOTO, T
FUTAMOTO, M
机构
[1] Central Research Laboratory, Hitachi Ltd., Kokubunji, Tokyo
来源
关键词
MAGNETIC FORCE MICROSCOPE; SPECTRUM ANALYSIS; MAGNETIZATION STRUCTURE; LONGITUDINAL RECORDING MEDIUM; NOISE CHARACTERISTICS;
D O I
10.1143/JJAP.34.L987
中图分类号
O59 [应用物理学];
学科分类号
摘要
Spectrum analyses of recorded magnetization were performed using magnetic force microscopic (MFM) images to quantitatively analyze the relationship between the magnetization structure and the reproduced signal output. Repeated one-dimensional Fourier analyses were performed on an MFM image along the recording direction of the disk medium for a certain width with a pitch of about 70 nm. The dependence of MFM signal intensity on wavelength was obtained through Fourier transformation. Differences in the noise characteristics of CoCrTa media with different Cr compositions were investigated. Several peaks in the Fourier-transformed spectrum are related to the magnetic cluster size and/or the magnetic cross-linking distance between neighboring recorded bits. The magnetic interactions were found to extend up to about 0.5 mu m and 1 mu m for magnetically recorded CoCr16Ta4 and CoCr10Ta4 media, respectively.
引用
下载
收藏
页码:L987 / L990
页数:4
相关论文
共 50 条
  • [41] Analysis of magnetization patterns measured using a magnetic force scanning tunneling microscope (abstract)
    Burke, E.R.
    Gomez, R.D.
    Mayergoyz, I.D.
    Journal of Applied Physics, 1994, 75 (10 pt 2B):
  • [42] Quantitative analysis of magnetization reversal in submicron S-patterned structures with narrow constrictions by magnetic force microscopy
    Chen, YC
    Yao, YD
    Lee, SF
    Liou, Y
    Tsai, JL
    Lin, YA
    APPLIED PHYSICS LETTERS, 2005, 86 (05) : 1 - 3
  • [43] Materials characterization using magnetic force microscopy
    Suzuki, Takayuki
    Sasamoto, Akira
    Nishimura, Yoshihiro
    Teramoto, Tokuo
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2008, 28 (1-2) : 163 - 169
  • [44] The Fourier analysis of magnetic force microscopy imaging
    Wu, Dongping
    Lou, Yuanfu
    Zheng, Fu
    Liu, Liwang
    Wei, Dan
    Wei, Fulin
    JOURNAL OF APPLIED PHYSICS, 2012, 112 (06)
  • [45] Analysis of Shingle-Write Readback Using Magnetic-Force Microscopy
    Lim, Fabian
    Wilson, Bruce
    Wood, Roger
    IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (06) : 1548 - 1551
  • [46] Quantitative Analysis of Magnetic Nanoparticles by Means of Magnetic Force Microscopy
    Schillik, A.
    Shao, R.
    Herr, U.
    Koslowski, B.
    IEEE TRANSACTIONS ON MAGNETICS, 2017, 53 (11)
  • [47] Incoherent magnetization reversal in Co-Pt nanodots investigated by magnetic force microscopy
    Pei, W. L.
    Qin, G. W.
    Ren, Y. P.
    Li, S.
    Wang, T.
    Hasegawa, H.
    Ishio, S.
    Yamane, H.
    ACTA MATERIALIA, 2011, 59 (12) : 4818 - 4824
  • [48] SWITCHING MAGNETIZATION MAGNETIC FORCE MICROSCOPY - AN ALTERNATIVE TO CONVENTIONAL LIFT-MODE MFM
    Cambel, Vladimir
    Gregusova, Dagmar
    Elias, Peter
    Fedor, Jan
    Kostic, Ivan
    Manka, Jan
    Ballo, Peter
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2011, 62 (01): : 37 - 43
  • [49] Magnetization reversal in MnAs films: Magnetic force microscopy, SQUID magnetometry, and micromagnetic simulations
    Engel-Herbert, R
    Hesjedal, T
    Mohanty, J
    Schaadt, DM
    Ploog, KH
    PHYSICAL REVIEW B, 2006, 73 (10)
  • [50] Investigation of Magnetization Distribution in Co/Au Multilayer Film by Magnetic Force Microscopy.
    Nurgazizov, N.
    Zhdan, P.
    Kisielewski, M.
    Stobiecki, F.
    MAGNETISM AND MAGNETIC MATERIALS, 2009, 152-153 : 277 - +