ACCURACY OF DISPOSABLE BLOOD-PRESSURE TRANSDUCERS USED IN THE CRITICAL CARE SETTING

被引:7
|
作者
BAILEY, RH
BAUER, JH
YANOS, J
机构
[1] UNIV MISSOURI, DIV PULM CRIT CARE & ENVIRONM MED, COLUMBIA, MO USA
[2] UNIV MISSOURI, DIV NEPHROL, HYPERTENS RES SECT, COLUMBIA, MO USA
[3] UNIV MISSOURI, DEPT INTERNAL MED, COLUMBIA, MO USA
[4] HARRY S TRUMAN MEM VET HOSP, COLUMBIA, MO 65201 USA
[5] CASE WESTERN RESERVE UNIV, DEPT MED, CLEVELAND, OH 44106 USA
关键词
TRANSDUCERS; PRESSURE; BLOOD PRESSURE DETERMINATION; CRITICAL CARE; BLOOD PRESSURE; CENTRAL VENOUS PRESSURE; MANOMETRY; MONITORING; PHYSIOLOGICAL;
D O I
10.1097/00003246-199501000-00029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To assess the initial accuracy, drift in calibration over several hours, and decline in accuracy over daily use of blood pressure transducers used in the critical care setting. Design: Prospective, criterion standard. Setting: Three critical care units in a university hospital. Subjects: Twenty-seven consecutively available high-pressure transducers were used to measure intra-arterial blood pressures, and 11 consecutively available low-pressure transducers were used to measure central venous and pulmonary arterial blood pressures. Interventions: High-pressure transducers were compared with a mercury column manometer, and low-pressure transducers were compared with a water column manometer at three pressure levels. Data were collected initially after installation of the pressure transducer, at 3 hrs, and at 6 hrs. Data collections were repeated on subsequent days. Measurements and Main Results: a) The majority of pressure transducers are accurate; b) there is no drift in the accuracy of pressure transducers over several hours; c) the accuracy of pressure transducers does not decline over subsequent days. Some transducers overestimated standard pressures by 10 mm Hg and/or underestimated standard pressure by 17 mm Hg. Conclusions: The majority of pressure transducers used in the critical care setting are accurate, although there are some transducers that may compromise patient care. Blood pressure transducers should be checked against a standard manometer upon installation, and daily during use.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 50 条
  • [31] ACCURACY AND ANALYSIS OF AMBULATORY BLOOD-PRESSURE MONITORING DATA
    WHITE, WB
    CLINICAL CARDIOLOGY, 1992, 15 (10) : 10 - 13
  • [32] ACCURACY OF AUSCULTATORY BLOOD-PRESSURE MEASUREMENT WITH A LONG CUFF
    VANMONTFRANS, GA
    VANDERHOEVEN, GMA
    KAREMAKER, JM
    WIELING, W
    DUNNING, AJ
    BRITISH MEDICAL JOURNAL, 1987, 295 (6594): : 354 - 355
  • [33] ACCURACY OF BLOOD-PRESSURE MEASUREMENTS MADE ABOARD HELICOPTERS
    LOW, RB
    MARTIN, D
    ANNALS OF EMERGENCY MEDICINE, 1988, 17 (06) : 604 - 612
  • [34] ACCURACY OF NONINVASIVELY MEASURED BLOOD-PRESSURE FROM A FINGER
    DAS, G
    ELADASARI, B
    CZERNEK, P
    CLINICAL RESEARCH, 1993, 41 (01): : A12 - A12
  • [35] Ambulatory Blood Pressure Monitoring Should Be Used in the Primary Care Setting to Diagnose Hypertension
    Davis, T. Keefe
    Davis, A. Jill
    AMERICAN JOURNAL OF HYPERTENSION, 2013, 26 (09) : 1057 - 1058
  • [36] Improving Blood Pressure Accuracy in the Outpatient Adolescent Setting
    Woods, Jennifer L.
    Jacobs, Megan D.
    Sheeder, Jeanelle L.
    PEDIATRIC QUALITY & SAFETY, 2021, 6 (04) : e416
  • [37] Blood product transfusion in the critical care setting
    Kor, Daryl J.
    Gajic, Ognjen
    CURRENT OPINION IN CRITICAL CARE, 2010, 16 (04) : 309 - 316
  • [38] DETERMINATION OF CLINICAL ACCURACY AND NOCTURNAL BLOOD-PRESSURE PATTERN BY NEW PORTABLE DEVICE FOR MONITORING INDIRECT AMBULATORY BLOOD-PRESSURE
    IMAI, Y
    ABE, K
    SASAKI, S
    MINAMI, N
    MUNAKATA, M
    SEKINO, H
    NIHEI, M
    YOSHINAGA, K
    AMERICAN JOURNAL OF HYPERTENSION, 1990, 3 (04) : 293 - 301
  • [39] CROWDING - ITS EFFECTS ON ELEVATION OF BLOOD-PRESSURE IN A PRISON SETTING
    DATRI, DA
    OSTFELD, AM
    PREVENTIVE MEDICINE, 1975, 4 (04) : 550 - 566
  • [40] 24-HOUR BLOOD-PRESSURE MONITORING IN AN AMBULATORY SETTING
    BOQUINHAS, JM
    BARRETO, JC
    GASPAR, A
    BOQUINHAS, MH
    SIMOES, J
    KIDNEY INTERNATIONAL, 1994, 45 (01) : 284 - 284