Preclinical evaluation of acoustic radiation force impulse measurements in regions of heterogeneous elasticity

被引:10
|
作者
Hollerieth, Katharina [1 ]
Gassmann, Bernhard [2 ]
Wagenpfeil, Stefan [3 ]
Moog, Philipp [1 ]
Minh-Truc Vo-Cong [1 ]
Heemann, Uwe [1 ]
Stock, Konrad Friedrich [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Nephrol, Str 22, D-81675 Munich, Germany
[2] Meso Int GmbH, Berlin, Germany
[3] Univ Saarland, Inst Med Biometry Epidemiol & Med Informat, Campus Homburg Saar, Homburg, Germany
关键词
Elasticity imaging techniques; Ultrasonography; Phantoms; imaging; Transducers; Heterogeneity;
D O I
10.14366/usg.16024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to compare the reliability of ultrasound-based shear wave elastography in regions of homogeneous versus heterogeneous elasticity by using two different probes. Methods: Using acoustic radiation force impulse (ARFI) elastography, we measured the shear wave velocity (SWV) in different lesions of an elastography phantom with the convex 4C1 probe and the linear 9L4 probe. The region of interest (ROI) was positioned in such a way that it was partly filled by one of the lesions (0%, 25%, 50%, 75%, and 100%) and partly by the background of the phantom (100%, 75%, 50%, 25%, and 0%, respectively). Results: The success rate was 98.5%. The measured value and the reference value of SWV correlated significantly (r=0.89, P<0.001). Further, a comparison of the two probes revealed that there was no statistical difference in either the mean or the variance values. However, the deviation of SWV from the reference was higher in the case of the 9L4 probe than in the case of the 4C1 probe, both overall and in measurements in which the ROI contained structures of different elasticity (P=0.021 and P=0.002). Taking into account all data, for both probes, we found that there was a greater spread and deviation of the SWV from the reference value when the ROI was positioned in structures having different elastic properties (standard deviation, 0.02 +/- 0.01 m/sec vs. 0.04 +/- 0.04 m/sec; P=0.010; deviation from the reference value, 0.21 +/- 0.12 m/sec vs. 0.38 +/- 0.27 m/sec; P=0.050). Conclusion: Quantitative ARFI elastography was achievable in structures of different elasticity; however, the validity and the reliability of the SWV measurements decreased in comparison to those of the measurements performed in structures of homogeneous elasticity. Therefore, a convex probe is preferred for examining heterogeneous structures.
引用
收藏
页码:345 / 352
页数:8
相关论文
共 50 条
  • [21] Acoustic Radiation Force Impulse (ARFI) Elastography in Evaluation of Supraspinatus Tendinopathy
    Serifoglu, Ismail
    Guneyli, Serkan
    Oz, Ibrahim Ilker
    Tosun, Alptekin
    CURRENT MEDICAL IMAGING, 2023, 19 (06) : 631 - 635
  • [22] Acoustic Radiation Force Impulse Technology and Fibroscan in the Evaluation of Liver Diseases
    Clevert, D.
    Zachoval, R.
    Reiser, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [23] Exploration of the human cervix using acoustic radiation force impulse (ARFI) measurements
    Feltovich, Helen
    Reusch, Lisa
    Palmeri, Mark
    Carlsen, Lindsey
    Hall, Timothy
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2012, 206 (01) : S218 - S218
  • [24] Renal tissue elasticity by acoustic radiation force impulse A prospective study of healthy kidney donors
    Lee, Alan
    Joo, Dong Jin
    Han, Woong Kyu
    Jeong, Hyeon Joo
    Oh, Min Jung
    Kim, Yu Seun
    Oh, Young Taik
    MEDICINE, 2021, 100 (03) : E23561
  • [25] Maternal liver elasticity determined by acoustic radiation force impulse elastosonography in intrahepatic cholestasis of pregnancy
    Orkun Cetin
    Erbil Karaman
    Harun Arslan
    Ibrahim Akbudak
    Recep Yildizhan
    Ali Kolusari
    Journal of Medical Ultrasonics, 2017, 44 : 255 - 261
  • [26] Maternal liver elasticity determined by acoustic radiation force impulse elastosonography in intrahepatic cholestasis of pregnancy
    Cetin, Orkun
    Karaman, Erbil
    Arslan, Harun
    Akbudak, Ibrahim
    Yildizhan, Recep
    Kolusari, Ali
    JOURNAL OF MEDICAL ULTRASONICS, 2017, 44 (03) : 255 - 261
  • [27] Renal elasticity quantification by acoustic radiation force impulse in children born preterm: preliminary results
    Zaffanello, Marco
    Bucci, Alessandra
    Brugnara, Milena
    Del Zotti, Emilio
    Bruno, Costanza
    JOURNAL OF PEDIATRIC AND NEONATAL INDIVIDUALIZED MEDICINE, 2015, 4 (01):
  • [28] Does elasticity of Achilles tendon change after suture applications? Evaluation of repair area by acoustic radiation force impulse elastography
    Karatekin, Yavuz Selim
    Karaismailoglu, Bedri
    Kaynak, Gokhan
    Ogut, Tahir
    Dikici, Atilla Suleyman
    Esmerer, Emel Ure
    Aydingoz, Onder
    Botanlioglu, Huseyin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [29] Does elasticity of Achilles tendon change after suture applications? Evaluation of repair area by acoustic radiation force impulse elastography
    Yavuz Selim Karatekin
    Bedri Karaismailoglu
    Gokhan Kaynak
    Tahir Ogut
    Atilla Suleyman Dikici
    Emel Ure Esmerer
    Onder Aydingoz
    Huseyin Botanlioglu
    Journal of Orthopaedic Surgery and Research, 13
  • [30] MEASUREMENT OF CORNEAL ELASTICITY WITH AN ACOUSTIC RADIATION FORCE ELASTICITY MICROSCOPE
    Mikula, Eric
    Hollman, Kyle
    Chai, Dongyul
    Jester, James V.
    Juhasz, Tibor
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (07): : 1671 - 1679