Preclinical evaluation of acoustic radiation force impulse measurements in regions of heterogeneous elasticity

被引:10
|
作者
Hollerieth, Katharina [1 ]
Gassmann, Bernhard [2 ]
Wagenpfeil, Stefan [3 ]
Moog, Philipp [1 ]
Minh-Truc Vo-Cong [1 ]
Heemann, Uwe [1 ]
Stock, Konrad Friedrich [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Nephrol, Str 22, D-81675 Munich, Germany
[2] Meso Int GmbH, Berlin, Germany
[3] Univ Saarland, Inst Med Biometry Epidemiol & Med Informat, Campus Homburg Saar, Homburg, Germany
关键词
Elasticity imaging techniques; Ultrasonography; Phantoms; imaging; Transducers; Heterogeneity;
D O I
10.14366/usg.16024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to compare the reliability of ultrasound-based shear wave elastography in regions of homogeneous versus heterogeneous elasticity by using two different probes. Methods: Using acoustic radiation force impulse (ARFI) elastography, we measured the shear wave velocity (SWV) in different lesions of an elastography phantom with the convex 4C1 probe and the linear 9L4 probe. The region of interest (ROI) was positioned in such a way that it was partly filled by one of the lesions (0%, 25%, 50%, 75%, and 100%) and partly by the background of the phantom (100%, 75%, 50%, 25%, and 0%, respectively). Results: The success rate was 98.5%. The measured value and the reference value of SWV correlated significantly (r=0.89, P<0.001). Further, a comparison of the two probes revealed that there was no statistical difference in either the mean or the variance values. However, the deviation of SWV from the reference was higher in the case of the 9L4 probe than in the case of the 4C1 probe, both overall and in measurements in which the ROI contained structures of different elasticity (P=0.021 and P=0.002). Taking into account all data, for both probes, we found that there was a greater spread and deviation of the SWV from the reference value when the ROI was positioned in structures having different elastic properties (standard deviation, 0.02 +/- 0.01 m/sec vs. 0.04 +/- 0.04 m/sec; P=0.010; deviation from the reference value, 0.21 +/- 0.12 m/sec vs. 0.38 +/- 0.27 m/sec; P=0.050). Conclusion: Quantitative ARFI elastography was achievable in structures of different elasticity; however, the validity and the reliability of the SWV measurements decreased in comparison to those of the measurements performed in structures of homogeneous elasticity. Therefore, a convex probe is preferred for examining heterogeneous structures.
引用
收藏
页码:345 / 352
页数:8
相关论文
共 50 条
  • [1] Application of acoustic radiation force impulse imaging for the evaluation of focal liver lesion elasticity
    Zhang, Ping
    Zhou, Ping
    Tian, Shuang-Ming
    Qian, Ying
    Deng, Jin
    Zhang, Lu
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2013, 12 (02) : 165 - 170
  • [2] Application of acoustic radiation force impulse imaging for the evaluation of focal liver lesion elasticity
    Ping Zhang
    Ping Zhou
    Shuang-Ming Tian
    Ying Qian
    Jin Deng
    Lu Zhang
    Hepatobiliary&PancreaticDiseasesInternational, 2013, 12 (02) : 165 - 170
  • [3] Acoustic Radiation Force Impulse Imaging for Evaluation of Renal Parenchyma Elasticity in Diabetic Nephropathy
    Goya, Cemil
    Kilinc, Faruk
    Hamidi, Cihad
    Yavuz, Alpaslan
    Yildirim, Yasar
    Cetincakmak, Mehmet Guli
    Hattapoglu, Salih
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (02) : 324 - 329
  • [4] Renal Elasticity Quantification by Acoustic Radiation Force Impulse Applied to the Evaluation of Kidney Diseases: A Review
    Zaffanello, Marco
    Piacentini, Giorgio
    Bruno, Costanza
    Brugnara, Milena
    Fanos, Vassilios
    JOURNAL OF INVESTIGATIVE MEDICINE, 2015, 63 (04) : 605 - 612
  • [5] Acoustic Radiation Force Impulse Imaging for Noninvasive Evaluation of Renal Parenchyma Elasticity: Preliminary Findings
    Guo, Le-Hang
    Xu, Hui-Xiong
    Fu, Hui-Jun
    Peng, Ai
    Zhang, Yi-Feng
    Liu, Lin-Na
    PLOS ONE, 2013, 8 (07):
  • [6] Acoustic Radiation Force Impulse Quantification in the Evaluation of Thyroid Elasticity in Pediatric Patients With Hashimoto Thyroiditis
    Yucel, Serap
    Bilgici, Meltem Ceyhan
    Kara, Cengiz
    Yilmaz, Gulay Can
    Aydin, H. Murat
    Elmali, Muzaffer
    Tomak, Leman
    Saglam, Dilek
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (05) : 1143 - 1149
  • [7] Acoustic radiation force impulse image for evaluation of parenchyma elasticity in acute hydronephrotic kidney: A preliminary report
    Chen, J-C
    Lu, S-Y
    Wang, H-K
    Lin, T-P
    Huang, W. J.
    EUROPEAN UROLOGY, 2024, 85 : S781 - S781
  • [8] Arterial stiffness measurements with acoustic radiation force impulse imaging
    Trahey, GE
    Dahl, JJ
    McAleavey, SA
    Gallippi, CM
    Nightingale, KR
    MEDICAL IMAGING 2003: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2003, 5035 : 235 - 241
  • [9] ACOUSTIC RADIATION FORCE IMPULSE IMAGE FOR EVALUATION OF PARENCHYMA ELASTICITY IN ACUTE HYDRONEPHROTIC KIDNEY: A PRELIMINARY REPORT
    Chen, Jen-Chieh
    Lu, Shih-Yen
    Lin, Tzu-Ping
    Huang, William J.
    JOURNAL OF UROLOGY, 2023, 209 : E667 - E667
  • [10] A new method for measurement of placental elasticity: Acoustic radiation force impulse imaging
    Sugitani, M.
    Fujita, Y.
    Yumoto, Y.
    Fukushima, K.
    Takeuchi, T.
    Shimokawa, M.
    Kato, K.
    PLACENTA, 2013, 34 (11) : 1009 - 1013