QUALITY ASSURANCE TOOL FOR HIGH-DOSE-RATE BRACHYTHERAPY

被引:18
|
作者
DEWERD, LA [1 ]
JURSINIC, P [1 ]
KITCHEN, R [1 ]
THOMADSEN, BR [1 ]
机构
[1] UNIV WISCONSIN,DEPT HUMAN ONCOL,MADISON,WI 53706
关键词
HIGH DOSE RATE BRACHYTHERAPY; QUALITY ASSURANCE; IR-192 REMOTE AFTERLOADERS; CALIBRATION;
D O I
10.1118/1.597469
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An insert for a well ionization chamber is described for quality assurance tests for high dose rate remote afterloaders. The use of this insert over time has shown its applicability for efficient QA tests for the high dose rate afterloader. The measurement results are six times greater than the uncertainties involved for the measurements. Checks on position can be made better than 1 mm and dwell times better than 1 s. The overall measurements can be done to better than 1.5%. QA checks can be accomplished in a shorter time period with as great or better accuracy than prior film techniques. © 1995, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:435 / 440
页数:6
相关论文
共 50 条
  • [41] Interstitial high-dose-rate brachytherapy in eyelid cancer
    Mareco, Virginia
    Bujor, Laurentiu
    Abrunhosa-Branquinho, Andre N.
    Ferreira, Miguel Reis
    Ribeiro, Tiago
    Vasconcelos, Ana Luisa
    Ferreira, Cidalina Reis
    Jorge, Marilia
    BRACHYTHERAPY, 2015, 14 (04) : 554 - 564
  • [42] FRACTIONATED HIGH-DOSE-RATE BRACHYTHERAPY FOR INTRACRANIAL GLIOMAS
    WOO, S
    BUTLER, EB
    GRANT, W
    BERNER, B
    GILDENBERG, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (01): : 247 - 249
  • [43] Postoperative Management of Keloids with High-Dose-Rate Brachytherapy
    Durante, S.
    Vavassori, A.
    Franzetti, J.
    Rotondi, M.
    Comi, S.
    Cambria, R.
    Cattani, F.
    De Lorenzi, F.
    Rietjens, M.
    Lazzari, R.
    Orecchia, R.
    Fossa, B. A. Jereczek
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1613 - S1613
  • [44] High-dose-rate brachytherapy in uterine cervical carcinoma
    Patel, FD
    Rai, B
    Mallick, I
    Sharma, SC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (01): : 125 - 130
  • [45] Developing a High-Dose-Rate Prostate Brachytherapy Program
    Waring, Jayne
    Gosselin, Tracy
    CLINICAL JOURNAL OF ONCOLOGY NURSING, 2010, 14 (02) : 199 - 205
  • [46] Automated Quality Assurance for Remote-Afterloading High Dose Rate Brachytherapy
    Kim, Anthony
    Ravi, Ananth
    MEDICAL PHYSICS, 2014, 41 (08) : 15 - 15
  • [47] High-dose-rate brachytherapy as monotherapy in prostate cancer
    Rebecca Kelsey
    Nature Reviews Urology, 2015, 12 (7) : 359 - 359
  • [48] Biologic treatment planning for high-dose-rate brachytherapy
    Manning, MA
    Zwicker, RD
    Arthur, DW
    Arnfield, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03): : 839 - 845
  • [49] Focal-Boost Dose Escalation in High-Dose-Rate Brachytherapy
    Guthier, C.
    Harris, T.
    King, M.
    Buzurovic, I.
    Cormack, R.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [50] A stochastic frontier analysis for enhanced treatment quality of high-dose-rate brachytherapy plans
    Edimo, Paul
    Kroshko, Angelika
    Beaulieu, Luc
    Archambault, Louis
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06):