QUALITY ASSURANCE TOOL FOR HIGH-DOSE-RATE BRACHYTHERAPY

被引:18
|
作者
DEWERD, LA [1 ]
JURSINIC, P [1 ]
KITCHEN, R [1 ]
THOMADSEN, BR [1 ]
机构
[1] UNIV WISCONSIN,DEPT HUMAN ONCOL,MADISON,WI 53706
关键词
HIGH DOSE RATE BRACHYTHERAPY; QUALITY ASSURANCE; IR-192 REMOTE AFTERLOADERS; CALIBRATION;
D O I
10.1118/1.597469
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An insert for a well ionization chamber is described for quality assurance tests for high dose rate remote afterloaders. The use of this insert over time has shown its applicability for efficient QA tests for the high dose rate afterloader. The measurement results are six times greater than the uncertainties involved for the measurements. Checks on position can be made better than 1 mm and dwell times better than 1 s. The overall measurements can be done to better than 1.5%. QA checks can be accomplished in a shorter time period with as great or better accuracy than prior film techniques. © 1995, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:435 / 440
页数:6
相关论文
共 50 条
  • [21] High-Dose-Rate Prostate Brachytherapy Consistently Results in High Quality Dosimetry
    White, Evan C.
    Kamrava, Mitchell R.
    Demarco, John
    Park, Sang-June
    Wang, Pin-Chieh
    Kayode, Oluwatosin
    Steinberg, Michael L.
    Demanes, D. Jeffrey
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02): : 543 - 548
  • [22] Modern development of high-dose-rate brachytherapy
    Itami, Jun
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2020, 50 (05) : 490 - 501
  • [23] VERIFICATION OF HIGH-DOSE-RATE BRACHYTHERAPY PLANS
    MOWER, HW
    LO, TC
    GIRSHOVICH, L
    LAWSON, BJ
    COSTEY, GE
    RADIOLOGY, 1992, 185 : 129 - 130
  • [24] "Magic phantom" - a quality assurance system for high dose rate brachytherapy
    Espinoza, A.
    Petasecca, M.
    Fuduli, I.
    Howie, A.
    Corde, S.
    Bucci, J.
    Jackson, M.
    Lerch, M. L. F.
    Rosenfeld, A. B.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S139 - S140
  • [25] Feasibility Study of Patient-specific Quality Assurance System for High-dose-rate Brachytherapy in Patients with Cervical Cancer
    Lee, Boram
    Ahn, Sung Hwan
    Kim, Hyeyoung
    Han, Youngyih
    Huh, Seung Jae
    Kim, Jin Sung
    Kim, Dong Wook
    Sim, Jina
    Yoon, Myonggeun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 68 (08) : L1029 - L1036
  • [26] A Quality Assurance System with a Web Camera for High Dose Rate Brachytherapy
    Ueda, Y.
    Hirose, A.
    Oohira, S.
    Isono, M.
    Tsujii, K.
    Miyazaki, M.
    Kawaguchi, Y.
    Konishi, K.
    Teshima, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3346 - 3346
  • [27] Feasibility study of patient-specific quality assurance system for high-dose-rate brachytherapy in patients with cervical cancer
    Boram Lee
    Sung Hwan Ahn
    Hyeyoung Kim
    Youngyih Han
    Seung Jae Huh
    Jin Sung Kim
    Dong Wook Kim
    Jina Sim
    Myonggeun Yoon
    Journal of the Korean Physical Society, 2016, 68 : 1029 - 1036
  • [28] Quality of life after high-dose-rate brachytherapy monotherapy for prostate cancer
    Contreras, Jessika A.
    Wilder, Richard B.
    Mellon, Eric A.
    Strom, Tobin J.
    Fernandez, Daniel C.
    Biagioli, Matthew C.
    INTERNATIONAL BRAZ J UROL, 2015, 41 (01): : 40 - 45
  • [29] Low-dose-rate brachytherapy is superior to high-dose-rate brachytherapy for bladder cancer
    Pos, FJ
    Horenblas, S
    Lebesque, J
    Moonen, L
    Schneider, C
    Sminia, P
    Bartelink, H
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (03): : 696 - 705
  • [30] The Effect of Needle Number on the Quality of High-dose-rate Prostate Brachytherapy Implants
    Froehlich, Georgina
    Agoston, Peter
    Loevey, Jozsef
    Polgar, Csaba
    Major, Tibor
    PATHOLOGY & ONCOLOGY RESEARCH, 2010, 16 (04) : 593 - 599