2-PHASE ELECTROPHORESIS OF PROTEINS

被引:25
|
作者
MARANDO, MA [1 ]
CLARK, WM [1 ]
机构
[1] WORCESTER POLYTECH INST,DEPT CHEM ENGN,WORCESTER,MA 01609
基金
美国国家科学基金会;
关键词
D O I
10.1080/01496399308018058
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Proteins have been directed into either the top or bottom phase of a polyethylene glycol/dextran aqueous two-phase system by applying an electric field perpendicular to the phase interface. Protein migration across the interface was manipulated by varying polarity, pH, electrophoresis time, field strength, and phase volume ratio. Mixtures of hemoglobin and albumin were separated by operating between isoelectric points and directing oppositely charged proteins into separate phases. Applying 50 V/cm for 2 hours to 58 mL of an equal phase volume two-phase system containing 0.2 g/L of each protein at pH 6 resulted in a bottom phase containing 99% of the hemoglobin and a top phase containing 95% of the albumin. This represents a significant improvement over the separation obtained either by partitioning in the same two-phase system with no applied field or by electrophoresis under the same conditions in homogeneous buffer. The two-phase system divides the electrophoresis device into two distinct regions, providing stability against convective mixing and facilitating product isolation.
引用
收藏
页码:1561 / 1577
页数:17
相关论文
共 50 条
  • [21] 2-PHASE FLOW
    MCKENZIE, RF
    CHEMICAL ENGINEERING PROGRESS, 1994, 90 (03) : 8 - &
  • [22] 2-PHASE VCO
    WORLEY, JM
    WIRELESS WORLD, 1976, 82 (1492): : 41 - 41
  • [23] 2-PHASE OSCILLATOR
    ZIMIN, NP
    YANENKO, AF
    MEASUREMENT TECHNIQUES, 1976, 19 (12) : 1787 - 1788
  • [24] 2-PHASE DOWNFLOW
    THORPE, RB
    BERESFORDPEIRSE, JD
    GIANCOLA, FL
    MCVAY, J
    TABBERER, RJ
    MULTI-PHASE FLOW: PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE, 1989, : 397 - 418
  • [25] NEW THEORETICAL APPROACHES TO AQUEOUS 2-PHASE SYSTEMS AND TO 2-PHASE PARTITIONING
    GUAN, Y
    LILLEY, TH
    TREFFRY, TE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 85 - IEC
  • [27] The comparative analysis of 2-Phase inverter topologies for 2-Phase induction motor
    Kim D.-K.
    Yoon D.-Y.
    Yoon, Duck-Yong (yoon3m@kongju.ac.kr), 1600, Korean Institute of Electrical Engineers (65): : 1013 - 1018
  • [28] ENGINEERING PROTEINS TO ENHANCE THEIR PARTITION-COEFFICIENTS IN AQUEOUS 2-PHASE SYSTEMS
    KOHLER, K
    LJUNGQUIST, C
    KONDO, A
    VEIDE, A
    NILSSON, B
    BIO-TECHNOLOGY, 1991, 9 (07): : 642 - 646
  • [29] PURIFICATION OF FUSION PROTEINS USING AFFINITY MICROSPHERES IN AQUEOUS 2-PHASE SYSTEMS
    KONDO, A
    KANEKO, T
    HIGASHITANI, K
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1993, 40 (2-3) : 365 - 369
  • [30] APPLICATION OF PLURONIC-F68 FOR AQUEOUS 2-PHASE EXTRACTION OF PROTEINS
    KITAHARA, T
    KAMIHIRA, M
    TAKEUCHI, H
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1993, 26 (02) : 183 - 188