ENZYMATIC DETERMINATION OF ALCOHOL MIXTURES AT THE NANOGRAM LEVEL BY THE STOPPED-FLOW TECHNIQUE

被引:25
|
作者
FORSTER, E
SILVA, M
OTTO, M
PEREZBENDITO, D
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
[2] BERGAKAD FREIBERG,INST ANALYT CHEM,W-9200 FREIBERG,GERMANY
关键词
ENZYMATIC METHODS; FLUOROMETRY; UV VISIBLE SPECTROPHOTOMETRY; ALCOHOLS; KALMAN FILTER; STOPPED-FLOW TECHNIQUE;
D O I
10.1016/0003-2670(93)80610-W
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive kinetic enzymatic method for the individual and joint determination of lower straight-chain alcohols is reported. The method is based on reaction of the alcohols with the alcohol dehydrogenase-nicotinamide adenine dinucleotide system, which is monitored by measuring the initial rate of change of the absorbance or fluorescence intensity of the reduced coenzyme formed by using the stopped-flow technique. Methanol, ethanol, propanol and butanol can thus be determined over the range 3.0 X 10(-8)-1.0 X 10(-6) M with a relative standard deviation of ca. 1.2-3.8%. Spectrofluorimetric measurements are better suited to the individual determinations, whereas spectrophotometric measurements are more useful for resolving alcohol mixtures using the Kalman filter algorithm. Mixtures of methanol-butanol, ethanol-butanol and methanol-propanol at the submicromolar level were successfully resolved with errors of less than 10%.
引用
收藏
页码:109 / 116
页数:8
相关论文
共 50 条
  • [21] KINETIC FLUOROMETRIC-DETERMINATION OF CARBAMAZEPINE IN SERUM BY THE STOPPED-FLOW TECHNIQUE
    DELAPENA, L
    GOMEZHENS, A
    PEREZBENDITO, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (07): : 821 - 823
  • [22] Chemiluminescence determination of glucose, fructose and their mixture by the stopped-flow mixing technique
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Tomás, V
    Fenoll, J
    MICROCHIMICA ACTA, 2003, 141 (1-2) : 73 - 78
  • [23] Chemiluminescence Determination of Glucose, Fructose and their Mixture by the Stopped-Flow Mixing Technique
    Tomás Pérez-Ruiz
    Carmen Martínez-Lozano
    Virginia Tomás
    José Fenoll
    Microchimica Acta, 2003, 141 : 73 - 78
  • [24] KINETIC FLUOROMETRIC-DETERMINATION OF PROMETHAZINE BY A STOPPED-FLOW MIXING TECHNIQUE
    DELAPENA, L
    GOMEZHENS, A
    PEREZBENDITO, D
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (10) : 893 - 896
  • [25] Spectrofluorimetric determination of naltrexone by a kinetic method using the stopped-flow technique
    Pulgarín, JAM
    Bermejo, LFG
    Lara, JLG
    ANALYTICA CHIMICA ACTA, 2003, 495 (1-2) : 249 - 259
  • [26] Reaction rate method for determination of nitrite by applying a stopped-flow technique
    Pettas, IA
    Lafis, SI
    Karayannis, MI
    ANALYTICA CHIMICA ACTA, 1998, 376 (03) : 331 - 337
  • [27] Determination of iodate ion in the presence of hydrogen peroxide with the stopped-flow technique
    Stanisavljev, Dragomir
    Bubanja, Itana Nusa
    Stevanovic, Kristina
    REACTION KINETICS MECHANISMS AND CATALYSIS, 2016, 118 (01) : 143 - 151
  • [28] Flow injection spectrofluorimetric method for determination of chromium(VI) using stopped-flow technique
    Tang, B
    Yue, TX
    Shi, XF
    Wu, JS
    Wang, Y
    ANALYTICAL LETTERS, 2005, 38 (02) : 303 - 315
  • [29] Stopped-flow technique and cationic polymerization kinetics
    Vairon, JP
    Charleux, B
    Moreau, M
    IONIC POLYMERIZATIONS AND RELATED PROCESSES, 1999, 359 : 177 - 204
  • [30] NEW FIELDS OF APPLICATION OF STOPPED-FLOW TECHNIQUE
    HIROMI, K