Reaction rate method for determination of nitrite by applying a stopped-flow technique

被引:24
|
作者
Pettas, IA [1 ]
Lafis, SI [1 ]
Karayannis, MI [1 ]
机构
[1] Univ Ioannina, Dept Chem, Ioannina 45100, Greece
关键词
kinetic measurement; nitrite determination; stopped-flow; catalytic effect;
D O I
10.1016/S0003-2670(98)00553-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, sensitive, and accurate method for the determination of nitrite is described based on its catalytic effect on the reaction between thymol blue and bromate in the presence of sulphuric acid. The optimum conditions for various parameters on which the rate of the reaction depends, such as temperature and pH, were investigated. The kinetics of the reaction were established by monitoring the decrease in absorbance of thymol blue at 543 nm by a stopped-flow technique. The linear calibration range for low concentration of nitrite ions was found to be 5-80 ng ml(-1)with a 2 sigma limit of detection of 4.5 ng ml(-1). The calibration for higher concentrations of nitrite was linear from 0.1 to 25 mu g ml(-1). The interference effect of several ions was investigated. The method can be extended to the determination of nitrate after their reduction to nitrite. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:331 / 337
页数:7
相关论文
共 50 条
  • [1] A Kinetic Spectrophotometric Method for the Determination of Nitrite by Stopped-Flow Technique
    Rui-Yong Wang
    Xiang Gao
    Ying-Tang Lu
    [J]. Analytical Sciences, 2006, 22 : 299 - 304
  • [2] A kinetic spectrophotometric method for the determination of nitrite by stopped-flow technique
    Wang, RY
    Gao, X
    Lu, YT
    [J]. ANALYTICAL SCIENCES, 2006, 22 (02) : 299 - 304
  • [3] THE REACTION OF PSEUDOMONAS NITRITE REDUCTASE AND NITRITE - A STOPPED-FLOW AND EPR STUDY
    SILVESTRINI, MC
    TORDI, MG
    MUSCI, G
    BRUNORI, M
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 1990, 265 (20) : 11783 - 11787
  • [4] Kinetic spectrophotometric method for determination of perphenazine based on monitoring the oxidation intermediate by applying a stopped-flow technique
    Wang, RY
    Lu, YT
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2005, 61 (05) : 791 - 797
  • [5] STOPPED-FLOW DETERMINATION OF PARACETAMOL AND OXYPHENBUTAZONE ALONE AND IN MIXTURES BY A DIFFERENTIAL REACTION-RATE METHOD
    CARMONA, M
    SILVA, M
    PEREZBENDITO, D
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 334 (03): : 261 - 265
  • [6] KINETIC DETERMINATION OF NITRITE BASED ON THE GRIESS REACTION AND THE STOPPED FLOW TECHNIQUE
    KARAYANNIS, MI
    PIPERAKI, EA
    MANIADAKI, MM
    [J]. ANALYTICAL LETTERS, 1986, 19 (1-2) : 13 - 23
  • [7] Spectrofluorimetric determination of naltrexone by a kinetic method using the stopped-flow technique
    Pulgarín, JAM
    Bermejo, LFG
    Lara, JLG
    [J]. ANALYTICA CHIMICA ACTA, 2003, 495 (1-2) : 249 - 259
  • [8] KINETIC DETERMINATION OF NITRITE IN WATERS BY USING A STOPPED-FLOW ANALYZER
    KOUPPARIS, MA
    WALCZAK, KM
    MALMSTADT, HV
    [J]. ANALYST, 1982, 107 (1280) : 1309 - 1315
  • [9] Flow injection spectrofluorimetric method for determination of chromium(VI) using stopped-flow technique
    Tang, B
    Yue, TX
    Shi, XF
    Wu, JS
    Wang, Y
    [J]. ANALYTICAL LETTERS, 2005, 38 (02) : 303 - 315
  • [10] Sensitive determination of diquat by a kinetic method using the stopped-flow mixing technique
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Tomás, V
    Fenoll, J
    [J]. ANALYST, 2000, 125 (12) : 2372 - 2375