Reaction rate method for determination of nitrite by applying a stopped-flow technique

被引:24
|
作者
Pettas, IA [1 ]
Lafis, SI [1 ]
Karayannis, MI [1 ]
机构
[1] Univ Ioannina, Dept Chem, Ioannina 45100, Greece
关键词
kinetic measurement; nitrite determination; stopped-flow; catalytic effect;
D O I
10.1016/S0003-2670(98)00553-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, sensitive, and accurate method for the determination of nitrite is described based on its catalytic effect on the reaction between thymol blue and bromate in the presence of sulphuric acid. The optimum conditions for various parameters on which the rate of the reaction depends, such as temperature and pH, were investigated. The kinetics of the reaction were established by monitoring the decrease in absorbance of thymol blue at 543 nm by a stopped-flow technique. The linear calibration range for low concentration of nitrite ions was found to be 5-80 ng ml(-1)with a 2 sigma limit of detection of 4.5 ng ml(-1). The calibration for higher concentrations of nitrite was linear from 0.1 to 25 mu g ml(-1). The interference effect of several ions was investigated. The method can be extended to the determination of nitrate after their reduction to nitrite. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:331 / 337
页数:7
相关论文
共 50 条
  • [31] KINETIC FLUOROMETRIC-DETERMINATION OF CARBAMAZEPINE IN SERUM BY THE STOPPED-FLOW TECHNIQUE
    DELAPENA, L
    GOMEZHENS, A
    PEREZBENDITO, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (07): : 821 - 823
  • [32] KINETIC DETERMINATION OF BINARY-MIXTURES OF PHENOLS WITH A STOPPED-FLOW TECHNIQUE
    PELIZZETTI, E
    GIRAUDI, G
    MENTASTI, E
    ANALYTICA CHIMICA ACTA, 1977, 94 (02) : 479 - 483
  • [33] Chemiluminescence determination of glucose, fructose and their mixture by the stopped-flow mixing technique
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Tomás, V
    Fenoll, J
    MICROCHIMICA ACTA, 2003, 141 (1-2) : 73 - 78
  • [34] KINETIC ENZYMATIC DETERMINATION OF ETHANOL METHANOL MIXTURES BY THE STOPPED-FLOW TECHNIQUE
    FORSTER, E
    SILVA, M
    OTTO, M
    PEREZBENDITO, D
    TALANTA, 1993, 40 (06) : 855 - 861
  • [35] Chemiluminescence Determination of Glucose, Fructose and their Mixture by the Stopped-Flow Mixing Technique
    Tomás Pérez-Ruiz
    Carmen Martínez-Lozano
    Virginia Tomás
    José Fenoll
    Microchimica Acta, 2003, 141 : 73 - 78
  • [36] AUTOMATED STOPPED-FLOW SYSTEMS FOR FAST REACTION-RATE METHODS
    CROUCH, SR
    HOLLER, FJ
    NOTZ, PK
    BECKWITH, PM
    APPLIED SPECTROSCOPY REVIEWS, 1977, 13 (02) : 165 - 259
  • [37] KINETIC FLUOROMETRIC-DETERMINATION OF PROMETHAZINE BY A STOPPED-FLOW MIXING TECHNIQUE
    DELAPENA, L
    GOMEZHENS, A
    PEREZBENDITO, D
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (10) : 893 - 896
  • [38] Chemiluminescence determination of citrate and pyruvate and their mixtures by the stopped-flow mixing technique
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Tomás, V
    Fenoll, J
    ANALYTICA CHIMICA ACTA, 2003, 485 (01) : 63 - 72
  • [39] Determination of rate constants for the activation step in atom transfer radical polymerization using the stopped-flow technique
    Pintauer, T
    Braunecker, W
    Collange, E
    Poli, R
    Matyjaszewski, K
    MACROMOLECULES, 2004, 37 (08) : 2679 - 2682
  • [40] ENZYMATIC DETERMINATION OF ALCOHOL MIXTURES AT THE NANOGRAM LEVEL BY THE STOPPED-FLOW TECHNIQUE
    FORSTER, E
    SILVA, M
    OTTO, M
    PEREZBENDITO, D
    ANALYTICA CHIMICA ACTA, 1993, 274 (01) : 109 - 116