Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system

被引:23
|
作者
Sharma, Reena [1 ]
Sharma, Sunil Dutt [1 ]
Pawar, Shramika [1 ]
Chaubey, Ajay [2 ]
Kantharia, S. [2 ]
Babu, D. A. R. [1 ]
机构
[1] CT & CRS, Radiol Phys & Advisory Div, Bombay, Maharashtra, India
[2] Bhabha Atom Res Ctr Hosp, Bombay, Maharashtra, India
关键词
Patient dose; entrance skin dose; diagnostic reference level; computed radiography; CR imaging system; X-ray machine; X-ray imaging;
D O I
10.4103/0971-6203.152244
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The screen-film system is replaced by computed radiography system for recording the images of the patients during X-ray radiography examinations. The change in imaging system requires the re-establishment of the institutional diagnostic reference levels (DRLs) for different types of X-ray examinations conducted at the hospital. For this purpose, patient specific parameters [age, height, weight, body mass index (BMI), object to image distance (OID)] and machine specific parameters (kVp, mAs, distance and field sizes) of 1875 patients during 21 different types of X-ray examinations were recorded for estimating the entrance skin dose (ESD). The ESD for each of these patients were estimated using measured X-ray beam output and the standard value of the back scatter factor. Five number summary was calculated for all the data for their presentation in the Box-Whisker plot, which provides the statistical distribution of the data. The data collected indicates that majorly performed examinations are cervical spine AP, Chest PA and Knee Lat with percentage contributions of 16.05, 16 and 8.27% respectively. The lowest contribution comes from Hip Lat which is about 1.01%. The ratio of measured ESD (maximum to minimum) for these examinations is found to be highest for the cervical spine AP with a value of 50 followed by Thoracic spine AP of 32.36. The ESD ratio for Chest PA, Knee Lat and Lumbar Spine AP are 30.75, 30.4 and 30.2 respectively. The lowest ESD ratio is for Hip Lat which is 2.68. The third quartile values of ESDs are established as the institutional DRLs. The ESD values obtained for 21 different X-ray projections are either comparable or lesser than the reported national/international values.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 50 条
  • [1] Investigation of Radiation Dose and Image Quality in X-Ray Radiographic Imaging
    Zainon, Rafidah
    Abu Talib, Nor Syazreena
    Abu Bakar, Siti Nur Amira
    Moner, Nur Hanisah Mohd
    Aziz, Nurul Athirah Abdul
    TRANSACTIONS ON ENGINEERING TECHNOLOGIES, 2015, : 361 - 368
  • [2] Radiation dose to procedural personnel and patients from an X-ray volume imaging system
    Jijo Paul
    Emmanuel C. Mbalisike
    Thomas J. Vogl
    European Radiology, 2013, 23 : 3262 - 3270
  • [3] Radiation dose to procedural personnel and patients from an X-ray volume imaging system
    Paul, Jijo
    Mbalisike, Emmanuel C.
    Vogl, Thomas J.
    EUROPEAN RADIOLOGY, 2013, 23 (12) : 3262 - 3270
  • [4] RADIATION DOSE MEASUREMENTS FOR OPTIMISATION OF CHEST X-RAY EXAMINATIONS OF CHILDREN IN GENERAL RADIOGRAPHY HOSPITALS
    Suliman, Ibrahim I.
    Elawed, Sahar O.
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (03) : 310 - 314
  • [5] COMPUTED RADIOGRAPHY SYSTEM USING AN IMAGING PLATE AS AN X-RAY SENSOR, TCR-201
    TAMURA, K
    KAKEGAWA, M
    NAKAGAWA, K
    TANIGUCHI, Y
    TOSHIBA REVIEW, 1986, (157): : 21 - 25
  • [6] RADIATION-DOSE TO CHILDREN FROM X-RAY AND RADIOISOTOPE EXAMINATIONS
    BUSHONG, SC
    GLAZE, D
    GLAZE, S
    SINGLETON, E
    HEALTH PHYSICS, 1978, 35 (05): : 720 - 721
  • [7] X-ray imaging plate using CsBr:Eu phosphors for computed radiography
    Nanto, H.
    Nishimura, A.
    Kuroda, M.
    Takei, Y.
    Nakano, Y.
    Shoji, T.
    Yanagita, T.
    Kasai, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 278 - 281
  • [8] The Imaging Dose to Patients Resulting From the ExacTrac X-Ray System
    Ding, G.
    Luo, G.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Effect of x-ray tube potential on image quality and patient dose for lumbar spine computed radiography examinations
    Brindhaban A.
    Al Khalifah K.
    Al Wathiqi G.
    Al Ostath H.
    Australasian Physics & Engineering Sciences in Medicine, 2005, 28 (4): : 216 - 222
  • [10] Patient dose and associated exposure parameters in pelvic x-ray examinations: dependence on radiographic system
    Welarathna, Sachith
    Velautham, Sivakumar
    Sarasanandarajah, Sivananthan
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (03) : 433 - 442