Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system

被引:23
|
作者
Sharma, Reena [1 ]
Sharma, Sunil Dutt [1 ]
Pawar, Shramika [1 ]
Chaubey, Ajay [2 ]
Kantharia, S. [2 ]
Babu, D. A. R. [1 ]
机构
[1] CT & CRS, Radiol Phys & Advisory Div, Bombay, Maharashtra, India
[2] Bhabha Atom Res Ctr Hosp, Bombay, Maharashtra, India
关键词
Patient dose; entrance skin dose; diagnostic reference level; computed radiography; CR imaging system; X-ray machine; X-ray imaging;
D O I
10.4103/0971-6203.152244
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The screen-film system is replaced by computed radiography system for recording the images of the patients during X-ray radiography examinations. The change in imaging system requires the re-establishment of the institutional diagnostic reference levels (DRLs) for different types of X-ray examinations conducted at the hospital. For this purpose, patient specific parameters [age, height, weight, body mass index (BMI), object to image distance (OID)] and machine specific parameters (kVp, mAs, distance and field sizes) of 1875 patients during 21 different types of X-ray examinations were recorded for estimating the entrance skin dose (ESD). The ESD for each of these patients were estimated using measured X-ray beam output and the standard value of the back scatter factor. Five number summary was calculated for all the data for their presentation in the Box-Whisker plot, which provides the statistical distribution of the data. The data collected indicates that majorly performed examinations are cervical spine AP, Chest PA and Knee Lat with percentage contributions of 16.05, 16 and 8.27% respectively. The lowest contribution comes from Hip Lat which is about 1.01%. The ratio of measured ESD (maximum to minimum) for these examinations is found to be highest for the cervical spine AP with a value of 50 followed by Thoracic spine AP of 32.36. The ESD ratio for Chest PA, Knee Lat and Lumbar Spine AP are 30.75, 30.4 and 30.2 respectively. The lowest ESD ratio is for Hip Lat which is 2.68. The third quartile values of ESDs are established as the institutional DRLs. The ESD values obtained for 21 different X-ray projections are either comparable or lesser than the reported national/international values.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 50 条
  • [41] THE RADIATION-DOSE TO CHILDREN FROM X-RAY EXAMINATIONS OF THE PELVIS AND THE URINARY-TRACT
    ALMEN, A
    MATTSSON, S
    BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (810): : 604 - 613
  • [42] UK population dose from medical X-ray examinations
    Hart, D
    Wall, BF
    EUROPEAN JOURNAL OF RADIOLOGY, 2004, 50 (03) : 285 - 291
  • [43] USE OF A COMPUTED RADIOGRAPHIC IMAGING-SYSTEM FOR LOW-DOSE PEDIATRIC CHEST RADIOGRAPHY
    KOGUTT, MS
    PEDIATRIC RADIOLOGY, 1987, 17 (04) : 337 - 337
  • [44] Assessment of the radiation dose associated with X-ray examinations using the DoseCal and CALDose_X software packages
    Saeed, M. K.
    Almalki, Y.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (01): : 191 - 197
  • [45] Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography
    Hall, G. N.
    Izumi, N.
    Landen, O. L.
    Tommasini, R.
    Holder, J. P.
    Hargrove, D.
    Bradley, D. K.
    Lumbard, A.
    Cruz, J. G.
    Piston, K.
    Lee, J. J.
    Romano, E.
    Bell, P. M.
    Carpenter, A. C.
    Palmer, N. E.
    Felker, B.
    Rekow, V.
    Allen, F. V.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [46] Radiation dose from X-ray examinations of impacted canines: cone beam CT vs two-dimensional imaging
    Kadesjo, Nils
    Lynds, Randi
    Nilsson, Mats
    Shi, Xie-Qi
    DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (03)
  • [47] PHYSICAL EVALUATION OF COMPUTED RADIOGRAPHY AS A MAMMOGRAPHIC X-RAY-IMAGING SYSTEM
    WORKMAN, A
    COWEN, AR
    BRETTLE, DS
    BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (802): : 988 - 996
  • [48] Improvement of imaging speed in fluorescent X-ray computed tomography using synchrotron radiation
    Hasegawa, Yasuhiro
    Yu, Quanwen
    Noto, Daisuke
    Takeda, Tohoru
    Hyodo, Kazuyuki
    Yashiro, Toru
    Yuasa, Tetsuya
    Hiranaka, Yukio
    Itai, Yuji
    Akatsuka, Takao
    Hasegawa, Y., 1600, John Wiley and Sons Inc. (33): : 1 - 11
  • [49] X-Ray Imaging Dose from IGRT
    Ding, G.
    MEDICAL PHYSICS, 2010, 37 (06) : 3409 - +
  • [50] In soil measurement of radiation dose caused by X-ray computed tomography
    Lippold, Eva
    Kleinau, Philip
    Blaser, Sebastian R. G. A.
    Schluter, Steffen
    Phalempin, Maxime
    Vetterlein, Doris
    JOURNAL OF PLANT NUTRITION AND SOIL SCIENCE, 2021, 184 (03) : 343 - 345