Establishing minimum free chlorine residual concentration for microbial control in a municipal drinking water distribution system

被引:3
|
作者
Rand, Jennie L. [1 ]
Gagnon, Graham A. [2 ]
Knowles, Alisha [3 ]
机构
[1] Acad Univ, Ivan Curry Sch Engn, Wolfville, NS B4P 2R6, Canada
[2] Dalhousie Univ, Dept Civil & Resource Engn, Halifax, NS B3H 4R2, Canada
[3] Halifax Water, Water Qual, Halifax, NS B3K 5M1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Chlorine; Disinfection Residual; Distribution System; Heterotrophic Bacteria; Municipal Water Supply; Regulations;
D O I
10.2166/wpt.2014.055
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Distribution system data from a Nova Scotia municipal drinking water supply was collected over four years, including free chlorine residual concentration, heterotrophic plate count (HPC) bacteria, and temperature. These data were analyzed for occurrences of HPC bacteria greater than 500 colony forming units (CFU)/mL. The municipality was interested in determining if secondary chlorination practices were sufficient in maintaining microbial health in their distribution system. Coliform data were non-detect (total coliforms and Escherichia coli) in the distribution system over this period and thus heterotrophic bacteria were used to assess microbial health. Results were compared to similar data collected from pilot-scale studies that had been carried out using the same municipal water as the source. Analysis showed that a similar trend was observed between pilot-and full-scale samples. Full-scale data analysis revealed that the minimum disinfection requirement of 0.2 mg/L did not consistently control occurrences of heterotrophic bacteria from being greater than 500 CFU/mL. By comparison, maintaining a concentration of 0.3 mg/L or above, particularly in warm-weather systems, maintained the number of heterotrophic bacteria at below 500 CFU/mL. Fortunately the majority of samples collected in the full-scale distribution system (> 89%) had a free chlorine residual concentration of greater than 0.30 mg/L. While it is recognized that this system had 100% compliance for E. coli, the goal of this work will help utilities understand how to utilize microbial data to inform operational disinfection targets for their distribution system.
引用
收藏
页码:491 / 501
页数:11
相关论文
共 50 条
  • [1] Free chlorine residual content within the drinking water distribution system
    Sarbatly, Rosalam H. J.
    Krishnaiah, Duduku
    INTERNATIONAL JOURNAL OF THE PHYSICAL SCIENCES, 2007, 2 (08): : 196 - 201
  • [2] Spatial diversity of chlorine residual in a drinking water distribution system
    Lee, LY
    Lu, CS
    Kung, SL
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2004, 130 (11) : 1263 - 1268
  • [3] Modeling Residual Chlorine Response to a Microbial Contamination Event in Drinking Water Distribution Systems
    Helbling, Damian E.
    VanBriesen, Jeanne M.
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2009, 135 (10): : 918 - 927
  • [4] Adaptive periodic control for chlorine residual maintenance in drinking water distribution networks
    Wang, Z
    Polycarpou, MM
    Uber, JG
    Shang, F
    PROCEEDINGS OF THE 40TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-5, 2001, : 4069 - 4074
  • [5] Analysis of residual chlorine in simple drinking water distribution system with intermittent water supply
    Goyal R.V.
    Patel H.M.
    Applied Water Science, 2015, 5 (03) : 311 - 319
  • [6] Residual chlorine in the extremities of the drinking water distribution system: the influence of stochastic water demands
    Blokker, M.
    Vreeburg, J.
    Speight, V.
    12TH INTERNATIONAL CONFERENCE ON COMPUTING AND CONTROL FOR THE WATER INDUSTRY, CCWI2013, 2014, 70 : 172 - 180
  • [7] Decay of Free Residual Chlorine in Drinking Water at the Point
    Sheikhi, Razieh
    Alimohammadi, Mahmood
    Askari, Masoomeh
    Moghaddasian, Mohammad Sadegh
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2014, 43 (04) : 535 - 536
  • [8] Residual chlorine modelling in drinking water distribution system of Bishoftu Town, Ethiopia
    Angassa, Kenatu
    Feyisa, Mulatu
    Tessema, Israel
    Abewaa, Mikiyas
    RESULTS IN ENGINEERING, 2025, 25
  • [9] Analysis of Free Residual Chlorine in Drinking Water Distribution Systems in Ore Processing Industry
    Susanto, Arif
    Amrina, Uli
    Purwanto, Purwanto
    Putro, Edi
    Yochu, Wiliam
    Wilmot, John
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2020, 29 (06): : 4321 - 4330
  • [10] Microbial Community Response to Chlorine Conversion in a Chloraminated Drinking Water Distribution System
    Wang, Hong
    Proctor, Caitlin R.
    Edwards, Marc A.
    Pryor, Marsha
    Domingo, Jorge W. Santo
    Ryu, Hodon
    Camper, Anne K.
    Olson, Andrew
    Pruden, Amy
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (18) : 10624 - 10633