INTERCOMPARISON OF INTERNAL PROPORTIONAL GAS COUNTING OF KR-85 AND H-3

被引:30
|
作者
MAKEPEACE, JL
CLARK, FE
PICOLO, JL
COURSOL, N
GUNTHER, E
UNTERWEGER, MP
机构
[1] LPRI,SACLAY,FRANCE
[2] PHYS TECH BUNDESANSTALT,BRAUNSCHWEIG,GERMANY
[3] NATL INST STAND & TECHNOL,GAITHERSBURG,MD 20899
关键词
D O I
10.1016/0168-9002(94)91829-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An international intercomparison of internal proportional gas counting of Kr-85 and H-3 has been carried out under the auspices of EUROMET, a European Collaboration in Measurement Standards. A sample of Kr-85 mixed with inactive krypton gas was measured at three laboratories and a sample of H-3 mixed with nitrogen gas was measured at four laboratories. In each case agreement was achieved within the stated uncertainties. The experimental techniques employed at each of the participating laboratories are described and a statement of the results and conclusions is provided.
引用
收藏
页码:343 / 348
页数:6
相关论文
共 50 条
  • [21] A GAS-PHASE KR-85 BETA EXCITED X-RAY SOURCE
    ARTMAN, C
    PREUSS, LE
    NUCLEAR INSTRUMENTS & METHODS, 1970, 78 (02): : 319 - &
  • [22] SIMULTANEOUS H-3 AND C-14 COUNTING BY A METHANE FILLED PROPORTIONAL COUNTER
    POVINEC, P
    NUCLEAR INSTRUMENTS & METHODS, 1980, 177 (2-3): : 465 - 469
  • [23] USE OF AN INERT RADIOACTIVE GAS KR-85, IN THE DETECTION AND QUANTIFICATION OF LEFT-TO-RIGHT SHUNTS
    SANDERS, RJ
    MORROW, AG
    CIRCULATION, 1958, 18 (04) : 775 - 775
  • [24] Certified reference gas of Kr-85 in a Marinelli beaker for calibrations of gamma-ray spectrometers
    Erbeszkorn, L
    Szorenyi, A
    Vagvolgyi, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (2-3): : 463 - 466
  • [25] A GLOBAL 3-DIMENSIONAL SOURCE RECEPTOR MODEL INVESTIGATION USING KR-85
    ZIMMERMANN, PH
    FEICHTER, J
    RATH, HK
    CRUTZEN, PJ
    WEISS, W
    ATMOSPHERIC ENVIRONMENT, 1989, 23 (01) : 25 - 35
  • [26] CALIBRATION OF A WELL-TYPE NAI(TI)-DETECTOR FOR ABSOLUTE COUNTING OF GASEOUS KR-85 AND XE-133
    CEJNAR, F
    KOVAR, I
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1977, 30 (5-6): : 341 - 348
  • [27] A NOVEL TECHNIQUE BASED ON KR-85 FOR QUANTIFICATION OF GAS-LIQUID MASS-TRANSFER IN BIOREACTORS
    PEDERSEN, AG
    ANDERSEN, H
    NIELSEN, J
    VILLADSEN, J
    CHEMICAL ENGINEERING SCIENCE, 1994, 49 (06) : 803 - 810
  • [28] MULTIELEMENT PROPORTIONAL-COUNTERS FOR LOW-LEVEL H-3 AND C-14 COUNTING
    POVINEC, P
    SZARKA, J
    USACEV, S
    NUCLEAR INSTRUMENTS & METHODS, 1979, 163 (2-3): : 369 - 375
  • [29] Optimization of simultaneous tritium-radiocarbon internal gas proportional counting
    Bonicalzi, R. M.
    Aalseth, C. E.
    Day, A. R.
    Hoppe, E. W.
    Mace, E. K.
    Moran, J. J.
    Overman, C. T.
    Panisko, M. E.
    Seifert, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 813 : 19 - 28
  • [30] SIMULTANEOUS GAS-PROPORTIONAL COUNTING OF H3 AND C14
    JORDAN, P
    NUCLEONICS, 1965, 23 (11): : 46 - &