Certified reference gas of Kr-85 in a Marinelli beaker for calibrations of gamma-ray spectrometers

被引:5
|
作者
Erbeszkorn, L [1 ]
Szorenyi, A [1 ]
Vagvolgyi, J [1 ]
机构
[1] NATL OFF MEASURE,BUDAPEST,HUNGARY
关键词
D O I
10.1016/S0168-9002(96)80031-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The activity of Kr-85 gas in a glass ampoule was measured by means of a solid certified reference source (CRS) of Sr-85 and a HPGe gamma-spectrometer. A Marinelli beaker of 101 was filled with Kr-85 gas and closed. The activity of the reference gas was checked in Marinelli-geometry also by means of a HPGe spectrometer which has been calibrated applying a mixed CRS and using the Measurements, Interpolations and Adding Up (MIAU) method. The deviation was less than 2% between the two methods.
引用
收藏
页码:463 / 466
页数:4
相关论文
共 19 条
  • [1] AN AUTOMATED KR-85 GAMMA-RAY STACK MONITOR
    GOLES, RW
    BRAUER, FP
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 740 - 744
  • [2] Coincidence summing effects in gamma-ray spectrometry using a Marinelli beaker
    Lee, Mosung
    Park, Tae Soon
    Woo, Jong-Kwan
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 799 - 803
  • [3] A DIRECT REFERENCE METHOD FOR MEASURING RADON ACTIVITY CONCENTRATIONS IN AIR BY GAMMA-RAY MEASUREMENT OF RADON IN A MARINELLI BEAKER
    MORE, H
    HUANG, ZJ
    APPLIED RADIATION AND ISOTOPES, 1992, 43 (1-2) : 103 - 109
  • [4] A NEW APPROACH TO THE DETERMINATION OF KR-85 IN AIR UTILIZING HIGH-RESOLUTION GAMMA-RAY SPECTROMETRY
    BHAT, RK
    OBED, R
    FEENEY, J
    HARRIS, J
    HEALTH PHYSICS, 1982, 43 (01): : 159 - 159
  • [5] Cascade summing in gamma-ray spectrometry in marinelli-beaker geometries: the third efficiency curve
    Blaauw, M
    Gelsema, SJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 311 - 315
  • [6] Development and application of Marinelli beaker standards for monitoring radioactivity in dairy-products by gamma-ray spectrometry
    Lavi, N
    Alfassi, ZB
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (06) : 1437 - 1441
  • [7] A GAS-PHASE KR-85 BETA EXCITED X-RAY SOURCE
    ARTMAN, C
    PREUSS, LE
    NUCLEAR INSTRUMENTS & METHODS, 1970, 78 (02): : 319 - &
  • [8] Production of 152,154Eu mixed sources for calibrations of gamma-ray spectrometers
    El Abd, A.
    Mostafa, M.
    El-Amir, M. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 293 (01) : 255 - 260
  • [9] Production of 152,154Eu mixed sources for calibrations of gamma-ray spectrometers
    A. El Abd
    M. Mostafa
    M. A. El-Amir
    Journal of Radioanalytical and Nuclear Chemistry, 2012, 293 : 255 - 260
  • [10] Production of Co-60 sources for high-accuracy efficiency calibrations of gamma-ray spectrometers
    Schönfeld, E
    Janssen, H
    Klein, R
    Hardy, JC
    Iacob, V
    Sanchez-Vega, M
    Griffin, HC
    Ludington, MA
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (1-2) : 215 - 221