BIAXIAL STRAIN ANALYSIS OF THE PORCINE AORTIC-VALVE

被引:50
|
作者
LO, D [1 ]
VESELY, I [1 ]
机构
[1] UNIV WESTERN ONTARIO,JOHN P ROBARTS RES INST,LONDON,ON,CANADA
来源
ANNALS OF THORACIC SURGERY | 1995年 / 60卷 / 02期
关键词
D O I
10.1016/0003-4975(95)00249-K
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The function of a bioprosthetic heart valve is determined largely by the material properties of the valve cusps. The mechanics of natural and bioprosthetic valve cusps have been studied extensively using uniaxial tensile testing. This type of testing, however, does not duplicate the natural biaxial loading condition. Whole-valve biaxial testing therefore is preferred. The objective of the present study was to investigate the heterogeneity of the valve cusps by mapping out the regional variability of the biaxial strain versus pressure relationship. Whole porcine aortic valves were mounted horizontally, submerged in physiologic saline solution at 37 degrees C, and pressurized in the range of 0 to 130 mm Hg of pressure. The ventricular side of the cusps were marked with black dots and the three-dimensional position of these dots was recorded together with the aortic pressure. By calculating the distance between the dots in the radial and circumferential directions in different regions, the local strain versus pressure relationship was determined. The results showed that the valve cusp material strained by 23% +/- 0.8% in the radial direction and 10.0% +/-0.5% in the circumferential direction before lock-up. It was also found that while the valve cusp was highly anisotropic in the central region, the basal region was relatively isotropic, and the cusp as a whole was asymmetrical in its distensibility.
引用
收藏
页码:S374 / S378
页数:5
相关论文
共 50 条
  • [21] THE MECHANICAL-PROPERTIES OF PORCINE AORTIC-VALVE TISSUES
    SAUREN, AAHJ
    VANHOUT, MC
    VANSTEENHOVEN, AA
    VELDPAUS, FE
    JANSSEN, JD
    JOURNAL OF BIOMECHANICS, 1983, 16 (05) : 327 - 337
  • [22] PORCINE AORTIC-VALVE BIOPROSTHESES - MORPHOLOGIC AND FUNCTIONAL CONSIDERATIONS
    HILBERT, SL
    FERRANS, VJ
    JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 1992, 2 (2-3) : 99 - 112
  • [23] REPLACEMENT OF A DEGENERATED PORCINE VALVE WITHIN A COMPOSITE AORTIC-VALVE GRAFT
    BRITTON, LW
    FOSTER, ED
    ANNALS OF THORACIC SURGERY, 1987, 43 (05): : 568 - 569
  • [24] HEART-VALVE REPLACEMENT BY PORCINE AORTIC-VALVE (HANCOCK PROSTHESIS)
    WRIGHT, JS
    NEWMAN, DC
    STACEY, RB
    MEDICAL JOURNAL OF AUSTRALIA, 1977, 1 (23) : 839 - 840
  • [25] AORTIC-VALVE REPLACEMENT WITH PRESERVED AORTIC-VALVE HOMOGRAFTS
    WALLACE, RB
    LONDE, SP
    TITUS, JL
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1974, 67 (01): : 44 - 52
  • [26] AORTIC-VALVE REPLACEMENT WITH PULMONARY OR AORTIC-VALVE ALLOGRAFTS
    LUPINETTI, FM
    LEMMER, JH
    FERGUSON, DW
    STANFORD, W
    BEHRENDT, DM
    CIRCULATION, 1990, 82 (04) : 764 - 764
  • [27] AORTIC-VALVE RING ABSCESS SUBSEQUENT TO BACTERIAL-ENDOCARDITIS OF THE AORTIC-VALVE AND AORTIC-VALVE REPLACEMENT
    RUFFMANN, K
    SCHWARZ, F
    SAGGAU, W
    MOBIUS, H
    SCHMITZ, W
    OTTO, H
    KUBLER, W
    ZEITSCHRIFT FUR KARDIOLOGIE, 1985, 74 (11): : 673 - 675
  • [28] ECHOCARDIOGRAPHY OF AORTIC-VALVE - STUDIES OF NORMAL AORTIC-VALVE, AORTIC-STENOSIS, AORTIC REGURGITATION, AND MIXED AORTIC-VALVE DISEASE
    FEIZI, O
    SYMONS, C
    YACOUB, M
    BRITISH HEART JOURNAL, 1974, 36 (04): : 341 - 351
  • [29] A BIOMECHANICAL ANALYSIS OF AORTIC-VALVE HISTOLOGY
    SAUREN, AAHJ
    VANSTEENHOVEN, AA
    VELDPAUS, FF
    JOURNAL OF BIOMECHANICS, 1980, 13 (09) : 810 - 811
  • [30] STENTLESS PORCINE BIOPROSTHESES IN THE TREATMENT OF AORTIC-VALVE INFECTIVE ENDOCARDITIS
    SANTINI, F
    MUSAZZI, A
    BERTOLINI, P
    PUGLIESE, P
    FABBRI, A
    FAGGIAN, G
    PRIOLI, A
    MAZZUCCO, A
    JOURNAL OF CARDIAC SURGERY, 1995, 10 (03) : 205 - 209