BIAXIAL STRAIN ANALYSIS OF THE PORCINE AORTIC-VALVE

被引:50
|
作者
LO, D [1 ]
VESELY, I [1 ]
机构
[1] UNIV WESTERN ONTARIO,JOHN P ROBARTS RES INST,LONDON,ON,CANADA
来源
ANNALS OF THORACIC SURGERY | 1995年 / 60卷 / 02期
关键词
D O I
10.1016/0003-4975(95)00249-K
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The function of a bioprosthetic heart valve is determined largely by the material properties of the valve cusps. The mechanics of natural and bioprosthetic valve cusps have been studied extensively using uniaxial tensile testing. This type of testing, however, does not duplicate the natural biaxial loading condition. Whole-valve biaxial testing therefore is preferred. The objective of the present study was to investigate the heterogeneity of the valve cusps by mapping out the regional variability of the biaxial strain versus pressure relationship. Whole porcine aortic valves were mounted horizontally, submerged in physiologic saline solution at 37 degrees C, and pressurized in the range of 0 to 130 mm Hg of pressure. The ventricular side of the cusps were marked with black dots and the three-dimensional position of these dots was recorded together with the aortic pressure. By calculating the distance between the dots in the radial and circumferential directions in different regions, the local strain versus pressure relationship was determined. The results showed that the valve cusp material strained by 23% +/- 0.8% in the radial direction and 10.0% +/-0.5% in the circumferential direction before lock-up. It was also found that while the valve cusp was highly anisotropic in the central region, the basal region was relatively isotropic, and the cusp as a whole was asymmetrical in its distensibility.
引用
收藏
页码:S374 / S378
页数:5
相关论文
共 50 条
  • [1] AORTIC-VALVE MECHANICS .2. STRESS ANALYSIS OF PORCINE AORTIC-VALVE LEAFLETS IN DIASTOLE
    CHONG, M
    ENG, M
    MISSIRLIS, YF
    BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1978, 6 (03): : 225 - 244
  • [2] AORTIC-VALVE MECHANICS .2. STRESS-ANALYSIS OF THE PORCINE AORTIC-VALVE LEAFLETS IN DIASTOLE
    GOULD, PL
    ROSSOW, MP
    BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1979, 7 (03): : 435 - 438
  • [3] MULTIFACTORIAL STENOSIS OF A PORCINE AORTIC-VALVE
    BORTOLOTTI, U
    MILANO, A
    VALFRE, C
    THIENE, G
    AMERICAN HEART JOURNAL, 1983, 106 (01) : 166 - 167
  • [4] EXPERIENCE WITH PORCINE AORTIC-VALVE XENOGRAFT
    LEVY, MJ
    YECHEZKEL, M
    DEVIRI, E
    LEVINSKY, L
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1984, 20 (06): : 562 - 562
  • [5] AORTIC-VALVE MECHANICS .2. STRESS-ANALYSIS OF THE PORCINE AORTIC-VALVE LEAFLETS IN DIASTOLE - REPLY
    MISSIRLIS, YF
    CHONG, M
    BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1979, 7 (03): : 439 - 442
  • [6] AORTIC-VALVE REPLACEMENT WITH A STENTLESS PORCINE AORTIC-VALVE - A 6-YEAR EXPERIENCE
    DAVID, TE
    FEINDEL, CM
    BOS, J
    SUN, Z
    SCULLY, HE
    RAKOWSKI, H
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 108 (06): : 1030 - 1036
  • [7] AORTIC-VALVE REPLACEMENT WITH STENTLESS PORCINE AORTIC BIOPROSTHESIS
    DAVID, TE
    POLLICK, C
    BOS, J
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1990, 99 (01): : 113 - 118
  • [8] FATAL THROMBOSIS OF A PORCINE AORTIC-VALVE GRAFT
    FRANKEN, P
    TAEYMANS, Y
    HENUZET, C
    RUTSAERT, J
    PRIMO, G
    NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (04): : 197 - 198
  • [9] ECHOCARDIOGRAPHIC FEATURES OF A STENOTIC PORCINE AORTIC-VALVE
    ALAM, M
    GOLDSTEIN, S
    AMERICAN HEART JOURNAL, 1980, 100 (04) : 517 - 519