AIR EXCHANGE RATE IN AIR QUALITY ASSURANCE - A CASE STUDY

被引:2
|
作者
Cirstoloveana, I. L. [1 ]
Hornet, M. [1 ]
Ancas, Ana Diana [2 ]
Profire, M. [2 ]
机构
[1] Transilvania Univ Brasov, Fac Bldg Engn, Brasov, Romania
[2] Tech Univ Gh Asachi Iasi, Fac Bldg Engn & Bldg Serv, Iasi, Romania
关键词
ventilation rate; thermal load; indoor temperature; measurements;
D O I
10.2478/jaes-2018-0002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The goals of this paper are to estimate some parameters - indoor temperature and ventilation rate - necessary to determine the heat load demand for ventilation in the amphitheatre named 'A TALPOSI'-Faculty of Buildings Engineering-with a number of at the most 120 occupants. The study presented in this paper is made when in the amphitheatre it is necessary to assure a comfortable temperature by a permanent functioning of the heating system. The number of air exchanges necessary in the amphitheatre in the natural ventilation process, more exactly, to assure a minimum air exchanges, is imposed by the requirements for the assurance of physiologic comfort in the amphitheatre for the time interval when it is occupied by students. The inner air debit should cover the harmful emissions in the amphitheatre. By the help of these calculated (measured) parameters we have calculated the heat load for ventilation. In the end, with the data obtained from calculations and measurements we find ourselves in the situation of establishing the size of the heat exchanger corresponding to the room, to heat the fresh air taken from outside and send it inside the amphitheatre. The measurements are made with the TESTO apparatus of the faculty. The minimum requirements to assure the thermal comfort are: to achieve a minimum internal temperature theta i (t) higher than (or equal to) the normal indoor temperature associated to this space and to assure the air quality, the air exchange rate. The authors want to highlight by this study the necessity and importance of the control on the number of air exchanges in rooms with a high number of occupants and overall, the control of the fresh air debits. The fact that the focus is more and more on heat loss cuts in rooms by tightening closing elements gives birth to the necessity of control of the ventilation system with effects on the consumption of mechanical energy.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 50 条
  • [31] Developing air exchange rate models by evaluating vehicle in-cabin air pollutant exposures in a highway and tunnel setting: case study of Tehran, Iran
    Mohammad Nayeb Yazdi
    Mohammad Arhami
    Maryam Delavarrafiee
    Mehdi Ketabchy
    Environmental Science and Pollution Research, 2019, 26 : 501 - 513
  • [32] Developing air exchange rate models by evaluating vehicle in-cabin air pollutant exposures in a highway and tunnel setting: case study of Tehran, Iran
    Yazdi, Mohammad Nayeb
    Arhami, Mohammad
    Delavarrafiee, Maryam
    Ketabchy, Mehdi
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (01) : 501 - 513
  • [33] Setting air quality standards: a case study of the Australian National Environment Protection Measure for Ambient Air Quality
    Beer, T
    ENVIRONMETRICS, 2000, 11 (05) : 499 - 510
  • [34] On the impact of urban surface exchange parameterisations on air quality simulations: the Athens case
    Martilli, A
    Roulet, YA
    Junier, M
    Kirchner, F
    Rotach, MW
    Clappier, A
    ATMOSPHERIC ENVIRONMENT, 2003, 37 (30) : 4217 - 4231
  • [35] A study on the staff's education quality - Assurance operation at Royal Thai Air Force Academy, the Royal Thai Air Force air education and training command
    Yongsorn, Chatupol
    Tangsomworapongs, Suwaporn
    3rd International Conference on Education and Information Systems: Technologies and Applications, Vol 1, Proceedings, 2005, : 280 - 283
  • [36] A proposed enhancement to the in air sensitivity test for ultrasound quality assurance
    Dudley, Nicholas J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 53 : 1 - 3
  • [38] ASSURANCE OF GUARANTEED ATMOSPHERE AIR QUALITY FOR A POINT EMISSION SOURCE
    Polishchuk, S.
    Falko, V
    Polishchuk, A.
    Demydenko, A.
    MINING OF MINERAL DEPOSITS, 2019, 13 (02): : 103 - 110
  • [39] INDOOR AIR QUALITY RELATED TO TOTAL MINIMUM AIR VENTILATION RATE, AIR QUALITY AND CFD SIMULATIONS OF POLLUTION DISTRIBUTION
    Nagy, Richard
    Kosicanova, Danica
    12th International Multidisciplinary Scientific Geoconference, SGEM 2012, Vol. IV, 2012, : 529 - 536
  • [40] The use of air quality forecasts to assess impacts of air pollution on crops: Methodology and case study
    Tong, Daniel
    Mathur, Rohit
    Schere, Kenneth
    Kang, Daiwen
    Yu, Shaocal
    ATMOSPHERIC ENVIRONMENT, 2007, 41 (38) : 8772 - 8784