REVERSE FLOW-INJECTION OR REAGENT INJECTION - NORMAL FLOW-INJECTION, REVERSE FLOW-INJECTION AND SINGLE-BOUNDARY MEASUREMENTS

被引:2
|
作者
FOGG, AG
DAVIES, AE
机构
关键词
REVERSE FLOW INJECTION; REAGENT INJECTION; SINGLE BOUNDARY MEASUREMENTS; NOMENCLATURE;
D O I
10.1039/an9921701055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The terms sample injection and reagent injection are inadequate in describing flow injection systems in which a monitorand that is not the determinand is produced on-line. The term reverse flow injection may not be self-evident, but terms such as normal flow injection and reverse flow injection can be used effectively to indicate whether a chemical species is in the injectate or the carrier stream, and whether a product is being formed by a concentration-limited species dispersing into or out of the bolus. Any term replacing the term reverse flow injection must be equally versatile. For flow analysis using a single boundary between two solutions there is a need for a term which indicates whether a chemical species, particularly if it is the determinand or a concentration-limited reagent forming a monitorand, is in the front or rear solution.
引用
收藏
页码:1055 / 1057
页数:3
相关论文
共 50 条
  • [21] FLOW-INJECTION ANALYSIS
    CHRISTIAN, GD
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (04) : R6 - R7
  • [22] REDUCTION OF INJECTION VARIANCE IN FLOW-INJECTION ANALYSIS
    JOHNSON, BF
    MALICK, RE
    DORSEY, JG
    [J]. TALANTA, 1992, 39 (01) : 35 - 44
  • [23] A SIMPLE INJECTION VALVE FOR FLOW-INJECTION ANALYSIS
    CHIPPERFIELD, JR
    WORSFOLD, PJ
    [J]. ANALYTICA CHIMICA ACTA, 1986, 181 : 283 - 285
  • [24] A VERSATILE INJECTION SYSTEM FOR FLOW-INJECTION ANALYSIS
    SOLLACARO, M
    DITTMAR, A
    LATER, R
    [J]. JOURNAL OF AUTOMATIC CHEMISTRY, 1992, 14 (03): : 101 - 105
  • [25] SPECTROPHOTOMETRIC SIMULTANEOUS DETERMINATION OF CREATININE AND CREATINE BY FLOW-INJECTION WITH REAGENT INJECTION
    DELCAMPO, G
    IRASTORZA, A
    CASADO, JA
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (06): : 557 - 561
  • [26] Chemiluminescence flow-injection immunoassays
    Gübitz, G
    Schmid, MG
    Silviaeh, H
    Aboul-Enein, HY
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2001, 31 (03) : 167 - 174
  • [27] SELECTIVITY IN FLOW-INJECTION ANALYSIS
    HANSEN, EH
    RUZICKA, J
    KRUG, FJ
    ZAGATTO, EAG
    [J]. ANALYTICA CHIMICA ACTA, 1983, 148 (APR) : 111 - 125
  • [28] FLOW-INJECTION ANALYSIS REVISITED
    RANGER, CB
    [J]. ANALYTICAL CHEMISTRY, 1982, 54 (11) : 1106 - 1106
  • [29] OSCILLOGRAPHIC FLOW-INJECTION ANALYSIS
    ZHENG, JB
    LIU, P
    SHI, SH
    [J]. CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1995, 16 (07): : 1016 - 1019
  • [30] FLOW-INJECTION ANALYSIS OF PHARMACEUTICALS
    DECASTRO, MDL
    VALCARCEL, M
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (12) : 1291 - 1300