REDUCTION OF INJECTION VARIANCE IN FLOW-INJECTION ANALYSIS

被引:8
|
作者
JOHNSON, BF [1 ]
MALICK, RE [1 ]
DORSEY, JG [1 ]
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
关键词
D O I
10.1016/0039-9140(92)80047-H
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to achieve maximum sensitivity in flow-injection analysis, sample dispersion must be kept to a minimum. This dispersion process, however, is not well understood. Studies of the dispersion process have concentrated on dispersion within the flow manifold while dispersion due to the injection process has been largely ignored. Here sample injection loops packed with inert glass beads and a Serpentine II (distorted) empty loop were constructed and compared to traditional empty sample loops. Digitization of the response curves and subsequent calculation of the statistical moments were used to compare the contribution of each sample loop type to the total system dispersion. Both packed and Serpentine II sample loops were shown to decrease dispersion and increase throughput in flow-injection systems. Plots of peak variance vs. injection volume show variance increasing 1.67 times faster with traditional open sample loops compared to packed loops. When combined with other peak width minimization techniques, this method should further lower concentration limits of detection.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 50 条
  • [1] RADIOMETRIC DETECTION IN FLOW-INJECTION ANALYSIS (RADIOMETRIC FLOW-INJECTION ANALYSIS)
    MYINT, U
    BA, H
    MYOE, KM
    KYWE, A
    THIDA
    TOLGYESSY, J
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1994, 187 (02): : 117 - 122
  • [2] INJECTION DEVICE IN FLOW-INJECTION ANALYSIS
    MELNIK, S
    FEJES, J
    CHEMICKE LISTY, 1985, 79 (09): : 910 - 918
  • [3] FLOW-INJECTION ANALYSIS
    LINDSAY, WN
    ANALYTICAL CHEMISTRY, 1981, 53 (03) : A387 - A387
  • [4] FLOW-INJECTION ANALYSIS
    ROCKS, B
    RILEY, C
    TRENDS IN BIOCHEMICAL SCIENCES, 1982, 7 (09) : 315 - 317
  • [5] FLOW-INJECTION ANALYSIS
    CHRISTIAN, GD
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (03) : R8 - R9
  • [6] FLOW-INJECTION ANALYSIS
    SHPIGUN, LK
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1990, 45 (06): : 751 - 757
  • [7] FLOW-INJECTION ANALYSIS
    CHRISTIAN, GD
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (04) : R6 - R7
  • [8] FLOW-REVERSAL FLOW-INJECTION ANALYSIS - ENHANCEMENT OF FLOW-INJECTION TITRATIONS
    CLARK, GD
    ZABLE, J
    RUZICKA, J
    CHRISTIAN, GD
    TALANTA, 1991, 38 (02) : 119 - 124
  • [9] A SIMPLE INJECTION VALVE FOR FLOW-INJECTION ANALYSIS
    CHIPPERFIELD, JR
    WORSFOLD, PJ
    ANALYTICA CHIMICA ACTA, 1986, 181 : 283 - 285
  • [10] A VERSATILE INJECTION SYSTEM FOR FLOW-INJECTION ANALYSIS
    SOLLACARO, M
    DITTMAR, A
    LATER, R
    JOURNAL OF AUTOMATIC CHEMISTRY, 1992, 14 (03): : 101 - 105