IMPORTANCE OF IN-VIVO DOSIMETRY AS PART OF A QUALITY ASSURANCE PROGRAM IN TANGENTIAL BREAST TREATMENTS

被引:10
|
作者
LEUNENS, G
VANDAM, J
DUTREIX, A
VANDERSCHUEREN, E
机构
[1] Department of Oncology and Radiotherapy, University Hospital St. Raphaël, Catholic University of Leuven, 3000 Leuven
关键词
BREAST CANCER; RADIATION THERAPY; QUALITY ASSURANCE; IN VIVO DOSIMETRY;
D O I
10.1016/0360-3016(94)90169-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The investigation of the accuracy and reproducibility in the daily dose delivered in tangential breast treatments with in vivo dose measurements. Methods and Materials: In vivo dose measurements performed on the tangential treatment fields of 35 breast cancer patients are analysed for three units: a 6 MV linear accelerator, an old Cobalt unit and a new Cobalt unit. The results are plotted in frequency distributions. Deviations on the mean are often the expression of a systematic error in one of the core procedures of a department. A large spread of the results around the mean indicates a high burden of random set-up errors and/or systematic errors in individual patients. The reproducibility in dose delivery is studied by comparing repetitive checks to their respective mean for investigation of random day-to-day variation. Results: A small systematic error on the entrance dose (+ 1.4%) is detected on the old Cobalt unit due to a discrepancy between measured and published percentage depth dose values. An unexpected systematic overdosage (+ 6%) is detected after implementation of a new software for dose calculation, proving that treatment quality is a process needing continuous monitoring. The transmission measurements demonstrate a systematic error in dose delivery of 1.5 to 3% due to the assumption that the breast is water equivalent when calculating the dose. The large spread of the transmission measurements (s(a) = 7.7%) shows that the weakest point in the treatment preparation chain is inaccurate acquisition of external body contours, leading to systematic errors in dose delivery for specific patients. The standard deviation for the reproducibility is 3.1% for the old Cobalt unit, vs. 1.6% on the other units, demonstrating the influence of staffing and mechanical characteristics of the units on daily precision in dose delivery. Conclusion: In vivo dosimetry is an important tool in a departmental quality assurance program to detect systematic errors in dose delivery, to identify inadequate treatment situations, to investigate weak points in the chain of treatment preparation and to ensure accurate dose delivery for individual patients. The predictive value of a single check for the accuracy in dose delivery during the whole treatment series is high for reproducible treatment methodologies.
引用
收藏
页码:285 / 296
页数:12
相关论文
共 50 条
  • [1] The use of diode in in-vivo dosimetry quality assurance in IMRT
    Kim, H
    Wang, Z
    Lalonde, R
    Sontag, M
    Chen, H
    Li, F
    Smith, R
    Huq, M
    Heron, D
    Yue, N
    MEDICAL PHYSICS, 2005, 32 (06) : 1988 - 1989
  • [2] In vivo semiconductor dosimetry as part of routine quality assurance
    Millwater, CJ
    Macleod, AS
    Thwaites, DI
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (846): : 661 - 668
  • [3] In-vivo quality assurance
    Bert, Christoph
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S55 - S56
  • [4] Verification of In-Vivo Dosimetry in TomoTherapy Treatments
    Chen, Q.
    Lu, W.
    Schnarr, E.
    Ruchala, K.
    Olivera, G.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [5] Implementation of in vivo dosimetry using diodes as part of quality assurance in radiotherapy
    Villegas, L. I.
    Espinoza, W. P.
    Bayas, M. V.
    IX LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2012, 1423
  • [6] Quality Assurance in radiation oncology. A one year in vivo dosimetry program in breast cancer patients
    Cozzi, L
    Fogliata, A
    PHYSICA MEDICA, 1997, 13 : 104 - 106
  • [7] A deformable head and neck phantom with in-vivo dosimetry for adaptive radiotherapy quality assurance
    Graves, Yan Jiang
    Smith, Arthur-Allen
    Mcilvena, David
    Manilay, Zherrina
    Lai, Yuet Kong
    Rice, Roger
    Mell, Loren
    Jia, Xun
    Jiang, Steve B.
    Cervino, Laura
    MEDICAL PHYSICS, 2015, 42 (04) : 1490 - 1497
  • [8] The Evaluation of In-Vivo Remote Dosimetry Program
    Lowenstein, J.
    Alvarez, P.
    Smith, A.
    Followill, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E608 - E608
  • [9] Implementation of in-vivo diode dosimetry for intensity modulated radiotherapy as routine patients' quality assurance
    AL-Shareef, Jamal M.
    Attalla, Ehab M.
    El-Gebaly, Reem H.
    Deiab, Nashaat A.
    Abdelmajeed, M.
    Fathy, Mohamed M.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 187
  • [10] Cost-effectiveness of the modifications in the quality assurance system in radiotherapy in the example of in-vivo dosimetry
    Malicki, Julian
    Litoborski, Marcin
    Bogusz-Czerniewicz, Marta
    Swiezewski, Adam
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (04): : 201 - 206