IMPORTANCE OF IN-VIVO DOSIMETRY AS PART OF A QUALITY ASSURANCE PROGRAM IN TANGENTIAL BREAST TREATMENTS

被引:10
|
作者
LEUNENS, G
VANDAM, J
DUTREIX, A
VANDERSCHUEREN, E
机构
[1] Department of Oncology and Radiotherapy, University Hospital St. Raphaël, Catholic University of Leuven, 3000 Leuven
关键词
BREAST CANCER; RADIATION THERAPY; QUALITY ASSURANCE; IN VIVO DOSIMETRY;
D O I
10.1016/0360-3016(94)90169-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The investigation of the accuracy and reproducibility in the daily dose delivered in tangential breast treatments with in vivo dose measurements. Methods and Materials: In vivo dose measurements performed on the tangential treatment fields of 35 breast cancer patients are analysed for three units: a 6 MV linear accelerator, an old Cobalt unit and a new Cobalt unit. The results are plotted in frequency distributions. Deviations on the mean are often the expression of a systematic error in one of the core procedures of a department. A large spread of the results around the mean indicates a high burden of random set-up errors and/or systematic errors in individual patients. The reproducibility in dose delivery is studied by comparing repetitive checks to their respective mean for investigation of random day-to-day variation. Results: A small systematic error on the entrance dose (+ 1.4%) is detected on the old Cobalt unit due to a discrepancy between measured and published percentage depth dose values. An unexpected systematic overdosage (+ 6%) is detected after implementation of a new software for dose calculation, proving that treatment quality is a process needing continuous monitoring. The transmission measurements demonstrate a systematic error in dose delivery of 1.5 to 3% due to the assumption that the breast is water equivalent when calculating the dose. The large spread of the transmission measurements (s(a) = 7.7%) shows that the weakest point in the treatment preparation chain is inaccurate acquisition of external body contours, leading to systematic errors in dose delivery for specific patients. The standard deviation for the reproducibility is 3.1% for the old Cobalt unit, vs. 1.6% on the other units, demonstrating the influence of staffing and mechanical characteristics of the units on daily precision in dose delivery. Conclusion: In vivo dosimetry is an important tool in a departmental quality assurance program to detect systematic errors in dose delivery, to identify inadequate treatment situations, to investigate weak points in the chain of treatment preparation and to ensure accurate dose delivery for individual patients. The predictive value of a single check for the accuracy in dose delivery during the whole treatment series is high for reproducible treatment methodologies.
引用
收藏
页码:285 / 296
页数:12
相关论文
共 50 条
  • [21] In-vivo dosimetry with EBT-3 gafchromic films and thermoluminescent dosimeters in breast cancer radiotherapy treatments
    Mvoufo Fokou
    Francis Hasford
    Maurice M. Ndontchueng
    Samuel A. Tagoe
    Ruth N. Njantang
    Theresa B. Dery
    Augustin Simo
    Kofi O. A. Larbi
    Philip Mantheaw
    Ernest Eduful
    Ousmanou Motapon
    Health and Technology, 2023, 13 : 585 - 600
  • [22] In-vivo dosimetry with EBT-3 gafchromic films and thermoluminescent dosimeters in breast cancer radiotherapy treatments
    Fokou, Mvoufo
    Hasford, Francis
    Ndontchueng, Maurice M.
    Tagoe, Samuel A.
    Njantang, Ruth N.
    Dery, Theresa B.
    Simo, Augustin
    Larbi, Kofi O. A.
    Mantheaw, Philip
    Eduful, Ernest
    Motapon, Ousmanou
    HEALTH AND TECHNOLOGY, 2023, 13 (04) : 585 - 600
  • [23] ACCURATE IN VIVO EPID DOSIMETRY FOR BREAST CANCER TREATMENTS
    Mans, A.
    Wendling, M.
    McDermott, L.
    Sonke, J. J.
    van Herk, M.
    Mijnheer, B.
    Stroom, J.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S70 - S71
  • [24] Quality Assurance of Small Animal Irradiation: Validation of a 3D-Printed Phantom for "Quasi In-Vivo" Dosimetry
    Koutsouvelis, N.
    Tournier, B. B.
    Garibotto, V.
    Jaccard, M.
    Dubouloz, A.
    Nouet, P.
    Rouzaud, M.
    Zilli, T.
    Dipasquale, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E476 - E476
  • [25] Dosimetry quality assurance of helical tomotherapy treatments, effect of density inhomogeneities
    Tomsej, M.
    Tondeur, V.
    De Patoul, N.
    Vynckier, S.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S508 - S508
  • [26] Improvement in radiosurgical plan dosimetry with implementation of a quality assurance program
    Salkeld, A. L.
    Wang, W.
    Nahar, N.
    Hau, E. K. C.
    Nahar, N.
    Sykes, J. R.
    Moodie, T.
    Thwaites, D. I.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1201 - S1202
  • [27] PATIENT DOSIMETRY QUALITY ASSURANCE PROGRAM WITH A COMMERCIAL DIODE SYSTEM
    LEE, PC
    SAWICKA, JM
    GLASGOW, GP
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 29 (05): : 1175 - 1182
  • [28] Routine EPID in-vivo dosimetry in a reference point for conformal radiotherapy treatments
    Fidanzio, Andrea
    Azario, Luigi
    Greco, Francesca
    Cilla, Savino
    Piermattei, Angelo
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08): : N141 - N150
  • [29] Clinical implementation of an in-vivo dosimetry system in conjunction with the RadCalc™ program
    Sehgal, V
    He, B
    Al-Ghazi, M
    MEDICAL PHYSICS, 2005, 32 (06) : 2003 - 2003
  • [30] In-Vivo Skin Dosimetry with EBT Radiochromic Films in Helical Tomotherapy Treatments
    Avanzo, M.
    Dassie, A.
    Drigo, A.
    Sartor, G.
    Capra, E.
    Cappelletto, C.
    Kaiser, S. Ren
    MEDICAL PHYSICS, 2008, 35 (06) : 2770 - +