Fluorescence polarization immunoassay based on fragmentary hapten for rapid and sensitive screening of polymyxins in human serum

被引:0
|
作者
Zhang, Yingjie [1 ]
Duan, Changfei [1 ]
Li, Qing [1 ]
Bai, Yuchen [1 ]
Dong, Baolei [2 ]
Tang, Yingying [1 ]
He, Min [1 ]
Hao, Chenqi [1 ]
Wen, Kai [1 ]
Shen, Jianzhong [1 ]
Wang, Zhanhui [1 ]
机构
[1] China Agr Univ, Coll Vet Med, Beijing Key Lab Detect Technol Anim Derived Food, Beijing Lab Food Qual & Safety, Beijing 100193, Peoples R China
[2] Hefei Univ Technol, Sch Food & Biol Engn, Hefei 230009, Anhui, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Polymyxins; Fragmentary hapten; Monoclonal antibody; Tracer structure; Fluorescence polarization immunoassay; Human serum;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polymyxin B (PMB) and polymyxin E (PME, or named colistin) are old polypeptide antibiotics and recently reintroduced as the last-line therapy for serious infections caused by multidrug-resistant Gram-negative pathogens. A rapid and reliable screening method for PMB and PME in human serum is urgently required due to their narrow therapeutic windows and individual differences. To develop fluorescence polarization immunoassay (FPIA) with high sensitivity and uniform specificity for PMB and PME, one novel fragmentary polymyxins hapten, named H1, was designed only containing the fatty acid acylated tripeptides and intendedly introducing sulfhydryl group for selective conjugation purpose. The H1 induced significantly higher titer and affinity antibody response than the PMB as hapten and produced five monoclonal antibodies (mAbs) with IC50 of 1.8-6.6 ng/mL for PMB and cross-reactions of 75.0-105.0 % for PME. To investigate the influence of tracer structure on the FPIA sensitivity, 12 tracers differing in spacer arm lengths, fluorophore types and hapten structures were fully paired with five mAbs, showing a safety length of spacer arm ranged from 4 to 17 & Aring;. Under optimal conditions, the IC50 of FPIA was 3.7 ng/mL in buffer with a limit of detection of 1.4 mu g/L in human serum for PMB and PME. The recoveries in spiked human serum were 73.8-91.8 % with CVs less than 12.8 % and whole assay time less than 25 min including sample preparation. These results showed that the FPIA was an efficient, accurate, and sensitive method for rapid screening of polymyxins and suitable for therapeutic drug monitoring.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] EVALUATION OF FLUORESCENCE POLARIZATION IMMUNOASSAY FOR SERUM THYROXINE DETERMINATION
    MURATSUGU, M
    MAKINO, M
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1982, 20 (08): : 567 - 570
  • [42] EVALUATION OF SERUM DIGOXIN ASSAY BY FLUORESCENCE POLARIZATION IMMUNOASSAY
    CHAUDHURI, J
    AMIRKHAN, N
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1237 - 1237
  • [43] EVALUATION OF FLUORESCENCE POLARIZATION IMMUNOASSAY FOR QUANTITATION OF SERUM SALICYLATES
    KARNES, HT
    BEIGHTOL, LA
    THERAPEUTIC DRUG MONITORING, 1985, 7 (03) : 351 - 354
  • [44] A rapid and sensitive chemiluminescence immunoassay based on magnetic particles for squamous cell carcinoma antigen in human serum
    Zhang, Huisheng
    Qi, Suwen
    CLINICA CHIMICA ACTA, 2011, 412 (17-18) : 1572 - 1577
  • [45] A MACROMOLECULAR FLUORESCENCE POLARIZATION IMMUNOASSAY FOR QUANTITATING HUMAN C-REACTIVE PROTEIN IN SERUM
    CHIAPPETTA, EG
    BENNETT, L
    SHAFFAR, M
    CLINICAL CHEMISTRY, 1985, 31 (06) : 910 - 910
  • [46] Comparison of the ARK Immunoassay to the Seradyn Fluorescence Polarization Immunoassay for Measurement of Serum Topiramate
    Snozek, Christine L. H.
    Rollins, Lisa A.
    Peterson, Paul W.
    Langman, Loralie J.
    THERAPEUTIC DRUG MONITORING, 2009, 31 (05) : 610 - 610
  • [47] FLUORESCENCE POLARIZATION IMMUNOASSAY OF SERUM DIGOXIN - COMPARISON OF THE ABBOTT IMMUNOASSAY WITH THE AMERLEX RADIOIMMUNOASSAY
    RAWAL, N
    LEUNG, FY
    HENDERSON, AR
    CLINICAL CHEMISTRY, 1983, 29 (03) : 586 - 586
  • [48] A fluorescence immunochromatographic assay for rapid and sensitive detection of human prealbumin in serum
    Yang, Yajie
    Li, Chaohui
    Wang, Wei
    Dong, Tingting
    Xiong, Yonghua
    Shen, Jun
    Lai, Weihua
    ANALYTICAL METHODS, 2015, 7 (20) : 8683 - 8688
  • [49] Novel hapten design, highly sensitive monoclonal antibody production, and immunoassay development for rapid screening of illegally added chloramphenicol in cosmetics
    Wang, Zhaoxiang
    Wang, Mian
    Fu, Xiaoxiang
    Qian, Jingqi
    Wang, Min
    Tan, Guiyu
    JOURNAL OF IMMUNOLOGICAL METHODS, 2024, 525
  • [50] Quantification of Diethyl Phthalate by a Rapid and Homogenous Fluorescence Polarization Immunoassay
    Tian, Xi
    Dong, Yaqing
    Wang, Yufen
    Song, Zhaorui
    Meng, Meng
    Eremin, Sergei A.
    Deng, Chuan
    Yin, Yongmei
    Xi, Rimo
    ANALYTICAL LETTERS, 2015, 48 (18) : 2843 - 2855