Fluorescence polarization immunoassay based on fragmentary hapten for rapid and sensitive screening of polymyxins in human serum

被引:0
|
作者
Zhang, Yingjie [1 ]
Duan, Changfei [1 ]
Li, Qing [1 ]
Bai, Yuchen [1 ]
Dong, Baolei [2 ]
Tang, Yingying [1 ]
He, Min [1 ]
Hao, Chenqi [1 ]
Wen, Kai [1 ]
Shen, Jianzhong [1 ]
Wang, Zhanhui [1 ]
机构
[1] China Agr Univ, Coll Vet Med, Beijing Key Lab Detect Technol Anim Derived Food, Beijing Lab Food Qual & Safety, Beijing 100193, Peoples R China
[2] Hefei Univ Technol, Sch Food & Biol Engn, Hefei 230009, Anhui, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Polymyxins; Fragmentary hapten; Monoclonal antibody; Tracer structure; Fluorescence polarization immunoassay; Human serum;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polymyxin B (PMB) and polymyxin E (PME, or named colistin) are old polypeptide antibiotics and recently reintroduced as the last-line therapy for serious infections caused by multidrug-resistant Gram-negative pathogens. A rapid and reliable screening method for PMB and PME in human serum is urgently required due to their narrow therapeutic windows and individual differences. To develop fluorescence polarization immunoassay (FPIA) with high sensitivity and uniform specificity for PMB and PME, one novel fragmentary polymyxins hapten, named H1, was designed only containing the fatty acid acylated tripeptides and intendedly introducing sulfhydryl group for selective conjugation purpose. The H1 induced significantly higher titer and affinity antibody response than the PMB as hapten and produced five monoclonal antibodies (mAbs) with IC50 of 1.8-6.6 ng/mL for PMB and cross-reactions of 75.0-105.0 % for PME. To investigate the influence of tracer structure on the FPIA sensitivity, 12 tracers differing in spacer arm lengths, fluorophore types and hapten structures were fully paired with five mAbs, showing a safety length of spacer arm ranged from 4 to 17 & Aring;. Under optimal conditions, the IC50 of FPIA was 3.7 ng/mL in buffer with a limit of detection of 1.4 mu g/L in human serum for PMB and PME. The recoveries in spiked human serum were 73.8-91.8 % with CVs less than 12.8 % and whole assay time less than 25 min including sample preparation. These results showed that the FPIA was an efficient, accurate, and sensitive method for rapid screening of polymyxins and suitable for therapeutic drug monitoring.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Lateral Flow Immunoassay Based on Time-Resolved Fluorescence Microspheres for Rapid and Quantitative Screening CA199 in Human Serum
    Jiao, Xueshima
    Peng, Tao
    Liang, Zhanwei
    Hu, Yalin
    Meng, Bo
    Zhao, Yang
    Xie, Jie
    Gong, Xiaoyun
    Jiang, You
    Fang, Xiang
    Yu, Xiaoping
    Dai, Xinhua
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (17)
  • [32] A highly specific and sensitive fluorescence polarization immunoassay for the rapid detection of triazophos residue in agricultural products
    Liu, Ying
    Liu, Rui
    Boroduleva, Anna
    Eremin, Sergei
    Guo, Yirong
    Zhu, Guonian
    ANALYTICAL METHODS, 2016, 8 (36) : 6636 - 6644
  • [33] Rapid Fluorescence Polarization Immunoassay for Highly Sensitive Detection of 2,4,6-Trinitrotoluene
    Lu, Wenzong
    Ni, Yuan
    Jia, Guangfeng
    Pan, Haixian
    Zhao, Chen
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (03) : 773 - 776
  • [34] Rapid fluorescence polarization immunoassay for the mycotoxin deoxynivalenol in wheat
    Maragos, CM
    Plattner, RD
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (07) : 1827 - 1832
  • [35] Antibody Production for a Rapid Fluorescence Polarization Immunoassay of Estrone
    ZHANG Xuan
    WANG Qiang
    YU Zhong
    Sergei A. Eremin
    YU Chun Fai
    LIU Jin
    SUN Yuan Ming
    LEI Hong Tao
    Biomedical and Environmental Sciences, 2014, 27 (01) : 52 - 55
  • [36] Antibody Production for a Rapid Fluorescence Polarization Immunoassay of Estrone
    Zhang Xuan
    Wang Qiang
    Yu Zhong
    Eremin, Sergei A.
    Yu Chun Fai
    Liu Jin
    Sun Yuan Ming
    Lei Hong Tao
    BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2014, 27 (01) : 52 - 55
  • [37] IMMUNOASSAY METHODS BASED ON FLUORESCENCE POLARIZATION
    GUTIERREZ, MC
    GOMEZHENS, A
    PEREZBENDITO, D
    TALANTA, 1989, 36 (12) : 1187 - 1201
  • [38] Quantitative screening of abused drugs by fluorescence polarization immunoassay
    Eremin, Sergei A.
    Sukhanova, Irina I.
    Rodchenkov, Grigory M.
    TOXICOLOGY LETTERS, 2008, 180 : S158 - S158
  • [39] BENZODIAZEPINE SCREENING-METHODS - THE FLUORESCENCE POLARIZATION IMMUNOASSAY
    MARTZ, S
    BEYER, KH
    ARCHIV DER PHARMAZIE, 1988, 321 (09) : 586 - 586
  • [40] EVALUATION OF THE FLUORESCENCE POLARIZATION IMMUNOASSAY FOR QUANTITATION OF DIGOXIN IN SERUM
    ALFARES, AM
    MIRA, SA
    ELSAYED, YM
    THERAPEUTIC DRUG MONITORING, 1984, 6 (04) : 454 - 457