Fluorescence polarization immunoassay based on fragmentary hapten for rapid and sensitive screening of polymyxins in human serum

被引:0
|
作者
Zhang, Yingjie [1 ]
Duan, Changfei [1 ]
Li, Qing [1 ]
Bai, Yuchen [1 ]
Dong, Baolei [2 ]
Tang, Yingying [1 ]
He, Min [1 ]
Hao, Chenqi [1 ]
Wen, Kai [1 ]
Shen, Jianzhong [1 ]
Wang, Zhanhui [1 ]
机构
[1] China Agr Univ, Coll Vet Med, Beijing Key Lab Detect Technol Anim Derived Food, Beijing Lab Food Qual & Safety, Beijing 100193, Peoples R China
[2] Hefei Univ Technol, Sch Food & Biol Engn, Hefei 230009, Anhui, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Polymyxins; Fragmentary hapten; Monoclonal antibody; Tracer structure; Fluorescence polarization immunoassay; Human serum;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polymyxin B (PMB) and polymyxin E (PME, or named colistin) are old polypeptide antibiotics and recently reintroduced as the last-line therapy for serious infections caused by multidrug-resistant Gram-negative pathogens. A rapid and reliable screening method for PMB and PME in human serum is urgently required due to their narrow therapeutic windows and individual differences. To develop fluorescence polarization immunoassay (FPIA) with high sensitivity and uniform specificity for PMB and PME, one novel fragmentary polymyxins hapten, named H1, was designed only containing the fatty acid acylated tripeptides and intendedly introducing sulfhydryl group for selective conjugation purpose. The H1 induced significantly higher titer and affinity antibody response than the PMB as hapten and produced five monoclonal antibodies (mAbs) with IC50 of 1.8-6.6 ng/mL for PMB and cross-reactions of 75.0-105.0 % for PME. To investigate the influence of tracer structure on the FPIA sensitivity, 12 tracers differing in spacer arm lengths, fluorophore types and hapten structures were fully paired with five mAbs, showing a safety length of spacer arm ranged from 4 to 17 & Aring;. Under optimal conditions, the IC50 of FPIA was 3.7 ng/mL in buffer with a limit of detection of 1.4 mu g/L in human serum for PMB and PME. The recoveries in spiked human serum were 73.8-91.8 % with CVs less than 12.8 % and whole assay time less than 25 min including sample preparation. These results showed that the FPIA was an efficient, accurate, and sensitive method for rapid screening of polymyxins and suitable for therapeutic drug monitoring.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Fluorescence polarization immunoassay based on fragmentary hapten for rapid and sensitive screening of polymyxins in human serum
    Zhang, Yingjie
    Duan, Changfei
    Li, Qing
    Bai, Yuchen
    Dong, Baolei
    Tang, Yingying
    He, Min
    Hao, Chenqi
    Wen, Kai
    Shen, Jianzhong
    Wang, Zhanhui
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 370
  • [2] Fluorescence polarization immunoassay based on fragmentary hapten for rapid and sensitive screening of polymyxins in human serum
    Zhang, Yingjie
    Duan, Changfei
    Li, Qing
    Bai, Yuchen
    Dong, Baolei
    Tang, Yingying
    He, Min
    Hao, Chenqi
    Wen, Kai
    Shen, Jianzhong
    Wang, Zhanhui
    Sensors and Actuators B: Chemical, 2022, 370
  • [3] Sensitive Rapid Fluorescence Polarization Immunoassay for Free Mycophenolic Acid Determination in Human Serum and Plasma
    Glahn-Martinez, Bettina
    Benito-Pena, Elena
    Salis, Francesca
    Descalzo, Ana B.
    Orellana, Guillermo
    Moreno-Bondi, Maria C.
    ANALYTICAL CHEMISTRY, 2018, 90 (08) : 5459 - 5465
  • [4] RAPID QUANTIFICATION OF PENTOBARBITAL IN SERUM BY FLUORESCENCE POLARIZATION IMMUNOASSAY
    LI, PK
    LEE, JT
    SCHREIBER, RM
    CLINICAL CHEMISTRY, 1984, 30 (02) : 307 - 308
  • [5] Development of a sensitive and rapid fluorescence polarization immunoassay for high throughput screening eight glucocorticoids in beef
    He, Shuang
    Liang, Demei
    Xiong, Jincheng
    Wang, Zile
    Zheng, Pimiao
    Zhang, Huixia
    Ren, Zhenhui
    Jiang, Haiyang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 214
  • [6] Fluorescence polarization immunoassay for rapid screening of ochratoxin A in red wine
    Francesco Zezza
    Francesco Longobardi
    Michelangelo Pascale
    Sergei A. Eremin
    Angelo Visconti
    Analytical and Bioanalytical Chemistry, 2009, 395 : 1317 - 1323
  • [7] Fluorescence polarization immunoassay for rapid screening of ochratoxin A in red wine
    Zezza, Francesco
    Longobardi, Francesco
    Pascale, Michelangelo
    Eremin, Sergei A.
    Visconti, Angelo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (05) : 1317 - 1323
  • [8] A Simple, Sensitive, Rapid and Specific Detection Method for Bisphenol A based on Fluorescence Polarization Immunoassay
    Wu, Xiaoling
    Wang, Libing
    Ma, Wei
    Zhu, Yingyue
    Xu, Liguang
    Kuang, Hua
    Xu, Chuanlai
    IMMUNOLOGICAL INVESTIGATIONS, 2012, 41 (01) : 38 - 50
  • [9] Fluorescence Polarization Immunoassay for Rapid, Accurate and Sensitive Determination of Ochratoxin A in Wheat
    Lippolis, Vincenzo
    Pascale, Michelangelo
    Valenzano, Stefania
    Porricelli, Anna Chiara Raffaella
    Suman, Michele
    Visconti, Angelo
    FOOD ANALYTICAL METHODS, 2014, 7 (02) : 298 - 307
  • [10] Fluorescence Polarization Immunoassay for Rapid, Accurate and Sensitive Determination of Ochratoxin A in Wheat
    Vincenzo Lippolis
    Michelangelo Pascale
    Stefania Valenzano
    Anna Chiara Raffaella Porricelli
    Michele Suman
    Angelo Visconti
    Food Analytical Methods, 2014, 7 : 298 - 307