USEFULNESS OF 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY FOR EVALUATION OF CAROTID-ARTERY BIFURCATION STENOSIS

被引:14
|
作者
UEHARA, T [1 ]
TABUCHI, M [1 ]
OHSUMI, Y [1 ]
YONEDA, Y [1 ]
MORI, E [1 ]
机构
[1] HYOGO INST AGING BRAIN & COGNIT DISORDERS,DEPT CLIN NEUROSCI,HIMEJI,HYOGO,JAPAN
关键词
MAGNETIC RESONANCE ANGIOGRAPHY; ANGIOGRAPHY; CEREBROVASCULAR DISEASE; CAROTID ARTERY STENOSIS; DIAGNOSIS;
D O I
10.1159/000107852
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We evaluated the usefulness of three-dimensional time-of-flight magnetic resonance angiography (3-D TOF MRA) in the estimation of carotid artery bifurcation stenosis by comparing it with conventional angiography in 81 vessels of 44 patients with cerebrovascular ischemic diseases. Agreement of interpretation on 3-D TOF MRA between two observers was equivalent to that on conventional angiography, indicating that both modalities were similarly reliable. A high correlation between MRA and conventional angiography assessments was apparent (Spearman rank correlation coefficients = 0.96, p = 0.0001). Calculating sensitivity and specificity of MRA for each cutoff point of severity, sensitivity ranged from 93.8 to 100%, and specificity from 96.1 to 98.5%. The only limitation of 3-D TOF MRA was that severe stenosis often mimicked occlusion. We concluded that 3-D TOF MRA is useful for evaluation of narrowing of carotid artery bifurcation.
引用
收藏
页码:199 / 203
页数:5
相关论文
共 50 条
  • [21] Flow voids in time-of-flight MR angiography of carotid artery stenosis? It depends on the TE!
    Lev, MH
    Romero, JM
    Gonzalez, RG
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2003, 24 (10) : 2120 - 2120
  • [22] CAROTID-ARTERY - PROSPECTIVE BLINDED COMPARISON OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH CONVENTIONAL ANGIOGRAPHY AND DUPLEX US
    HUSTON, J
    LEWIS, BD
    WIEBERS, DO
    MEYER, FB
    RIEDERER, SJ
    WEAVER, AL
    RADIOLOGY, 1993, 186 (02) : 339 - 344
  • [23] 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH A SURFACE COIL - EVALUATION IN 12 SUBJECTS
    HENDRIX, LE
    STRANDT, JA
    DANIELS, DL
    MARK, LP
    BORNE, JA
    CZERVIONKE, LF
    HAUGHTON, VM
    WILLIAMS, AL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (01) : 103 - 106
  • [24] Time-of-flight MR angiography of carotid artery stenosis: Does a flow void represent severe stenosis?
    Nederkoorn, PJ
    van der Graaf, Y
    Eikelboom, BC
    van der Lugt, A
    Bartels, LW
    Mali, WPTM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (10) : 1779 - 1784
  • [25] PULSE SEQUENCE STRATEGIES FOR VASCULAR CONTRAST IN TIME-OF-FLIGHT CAROTID MR-ANGIOGRAPHY
    TKACH, JA
    RUGGIERI, PM
    ROSS, JS
    MODIC, MT
    DILLINGER, JJ
    MASARYK, TJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06): : 811 - 820
  • [26] INTRACRANIAL ANEURYSMS - DIAGNOSTIC-ACCURACY OF 3-DIMENSIONAL, FOURIER-TRANSFORM, TIME-OF-FLIGHT MR-ANGIOGRAPHY
    KOROGI, Y
    TAKAHASHI, M
    MABUCHI, N
    MIKI, H
    FUJIWARA, S
    HORIKAWA, Y
    NAKAGAWA, T
    OUCHI, T
    WATABE, T
    SHIGA, H
    FURUSE, M
    RADIOLOGY, 1994, 193 (01) : 181 - 186
  • [27] ASSESSMENT OF CAROTID-ARTERY STENOSIS BY MR ANGIOGRAPHY
    ACKERMAN, RH
    CANDIA, MR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1992, 13 (03) : 1005 - 1008
  • [28] MOYAMOYA DISEASE - DIAGNOSIS WITH 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    YAMADA, I
    MATSUSHIMA, Y
    SUZUKI, S
    RADIOLOGY, 1992, 184 (03) : 773 - 778
  • [29] 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY - APPLICATIONS IN THE ABDOMEN AND THORAX
    LEWIN, JS
    LAUB, G
    HAUSMANN, R
    RADIOLOGY, 1991, 179 (01) : 261 - 264
  • [30] STEPS IN THE EVOLUTION OF EXTRACRANIAL TIME-OF-FLIGHT MR-ANGIOGRAPHY
    MARIANACCI, EB
    HARTNELL, GG
    BUFF, BL
    MOORE, JR
    FINN, JP
    RADIOGRAPHICS, 1994, 14 (06) : 1377 - 1387