STEPS IN THE EVOLUTION OF EXTRACRANIAL TIME-OF-FLIGHT MR-ANGIOGRAPHY

被引:0
|
作者
MARIANACCI, EB
HARTNELL, GG
BUFF, BL
MOORE, JR
FINN, JP
机构
[1] DEACONESS HOSP,DIV CARDIOL,BOSTON,MA 02215
[2] HARVARD UNIV,SCH MED,BOSTON,MA 02115
关键词
MAGNETIC RESONANCE (MR); K-SPACE; TIME OF FLIGHT; VASCULAR STUDIES;
D O I
10.1148/radiographics.14.6.7855347
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance (MR) angiography is not a set technique but is constantly evolving. This article illustrates changes in image quality in extracranial MR angiography that have been achieved over the past few years by the introduction of several technical developments. Images from patients examined at intervals of 12 months or more demonstrate the improvements in image quality that have resulted from these technical changes. These include bandwidth optimization for operation at 1.0 T and changes in flip angle, section thickness, repetition time, and echo time. Improved image quality was assessed with objective measures of contrast-to-noise and signal-to-noise ratios. The cases illustrated show the use of MR angiography to evaluate the portal or systemic veins in patients being evaluated for liver transplantation, venous occlusion, and other venous disease. Improvements in image quality are subjectively apparent and emphasize the importance of keeping pace with technical improvements in MR angiography.
引用
收藏
页码:1377 / 1387
页数:11
相关论文
共 50 条
  • [1] FAST TIME-OF-FLIGHT MR-ANGIOGRAPHY WITH IMPROVED BACKGROUND SUPPRESSION
    EDELMAN, RR
    CHIEN, D
    ATKINSON, DJ
    SANDSTROM, J
    RADIOLOGY, 1991, 179 (03) : 867 - 870
  • [2] OPTIMIZING 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY WITH VARIABLE REPETITION TIME
    TKACH, JA
    LIN, WL
    DUDA, JJ
    HAACKE, EM
    MASARYK, TJ
    RADIOLOGY, 1994, 191 (03) : 805 - 811
  • [3] PULSE SEQUENCE STRATEGIES FOR VASCULAR CONTRAST IN TIME-OF-FLIGHT CAROTID MR-ANGIOGRAPHY
    TKACH, JA
    RUGGIERI, PM
    ROSS, JS
    MODIC, MT
    DILLINGER, JJ
    MASARYK, TJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06): : 811 - 820
  • [4] TIME-OF-FLIGHT RENAL MR-ANGIOGRAPHY - UTILITY IN PATIENTS WITH RENAL-INSUFFICIENCY
    YUCEL, EK
    KAUFMAN, JA
    PRINCE, M
    BAZARI, H
    FANG, LST
    WALTMAN, AC
    MAGNETIC RESONANCE IMAGING, 1993, 11 (07) : 925 - 930
  • [5] ACETAZOLAMIDE CHALLENGE FOR 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY OF THE BRAIN
    MANDAI, K
    SUEYOSHI, K
    FUKUNAGA, R
    NUKADA, M
    OHTANI, F
    ARAKI, Y
    TSUKAGUCHI, I
    ABE, H
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (04) : 659 - 665
  • [6] PERIPHERAL VASCULAR OCCLUSIVE DISEASE - ACCURACY AND RELIABILITY OF TIME-OF-FLIGHT MR-ANGIOGRAPHY
    MCCAULEY, TR
    MONIB, A
    DICKEY, KW
    CLEMETT, J
    MEIER, GH
    EGGLIN, TK
    GUSBERG, RJ
    ROSENBLATT, M
    POLLAK, JS
    RADIOLOGY, 1994, 192 (02) : 351 - 357
  • [7] FAST 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY OF THE INTRACRANIAL VASCULATURE
    TALAGALA, SL
    JUNGREIS, CA
    KANAL, E
    MEYERS, SP
    FOO, TKF
    RUBIN, RA
    APPLEGATE, GR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 317 - 323
  • [8] GD-DTPA-POLYLYSINE ENHANCED PULMONARY TIME-OF-FLIGHT MR-ANGIOGRAPHY
    BOCK, JC
    PISON, U
    KAUFMANN, F
    FELIX, R
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03): : 473 - 476
  • [9] TIME-OF-FLIGHT MR ANGIOGRAPHY
    NISHIMURA, DG
    MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) : 194 - 201
  • [10] TIME-OF-FLIGHT MR-ANGIOGRAPHY OF THE BRAIN - COMPARISON OF ACQUISITION TECHNIQUES IN HEALTHY-VOLUNTEERS
    BOSMANS, H
    MARCHAL, G
    LUKITO, G
    YICHENG, N
    WILMS, G
    LAUB, G
    BAERT, AL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (01) : 161 - 167