STEPS IN THE EVOLUTION OF EXTRACRANIAL TIME-OF-FLIGHT MR-ANGIOGRAPHY

被引:0
|
作者
MARIANACCI, EB
HARTNELL, GG
BUFF, BL
MOORE, JR
FINN, JP
机构
[1] DEACONESS HOSP,DIV CARDIOL,BOSTON,MA 02215
[2] HARVARD UNIV,SCH MED,BOSTON,MA 02115
关键词
MAGNETIC RESONANCE (MR); K-SPACE; TIME OF FLIGHT; VASCULAR STUDIES;
D O I
10.1148/radiographics.14.6.7855347
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance (MR) angiography is not a set technique but is constantly evolving. This article illustrates changes in image quality in extracranial MR angiography that have been achieved over the past few years by the introduction of several technical developments. Images from patients examined at intervals of 12 months or more demonstrate the improvements in image quality that have resulted from these technical changes. These include bandwidth optimization for operation at 1.0 T and changes in flip angle, section thickness, repetition time, and echo time. Improved image quality was assessed with objective measures of contrast-to-noise and signal-to-noise ratios. The cases illustrated show the use of MR angiography to evaluate the portal or systemic veins in patients being evaluated for liver transplantation, venous occlusion, and other venous disease. Improvements in image quality are subjectively apparent and emphasize the importance of keeping pace with technical improvements in MR angiography.
引用
收藏
页码:1377 / 1387
页数:11
相关论文
共 50 条
  • [21] Computer simulation of Time-of-Flight MR angiography
    Jia, LH
    Hiller, J
    Lambert, T
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XIX, 1996, 2847 : 548 - 558
  • [22] VARIABLE-ANGLE UNIFORM SIGNAL EXCITATION (VUSE) FOR 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY
    PRIATNA, A
    PASCHAL, CB
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04): : 421 - 427
  • [23] USEFULNESS OF 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY FOR EVALUATION OF CAROTID-ARTERY BIFURCATION STENOSIS
    UEHARA, T
    TABUCHI, M
    OHSUMI, Y
    YONEDA, Y
    MORI, E
    CEREBROVASCULAR DISEASES, 1995, 5 (03) : 199 - 203
  • [24] ABDOMINAL AORTIC-ANEURYSMS - ASSESSMENT WITH GADOLINIUM-ENHANCED TIME-OF-FLIGHT CORONAL MR-ANGIOGRAPHY (MRA)
    LAISSY, JP
    SOYER, P
    TEBBOUNE, D
    TIAH, D
    HVASS, U
    MENU, Y
    EUROPEAN JOURNAL OF RADIOLOGY, 1995, 20 (01) : 1 - 8
  • [25] ILIAC ARTERY PATENCY BEFORE AND IMMEDIATELY AFTER PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY - ASSESSMENT WITH TIME-OF-FLIGHT MR-ANGIOGRAPHY
    LAISSY, JP
    LIMOT, O
    HENRYFEUGEAS, MC
    KARRILLON, GR
    HACKWORTH, CA
    JULLIARD, JM
    AUMONT, MC
    SCHOUMANCLAEYS, E
    RADIOLOGY, 1995, 197 (02) : 455 - 459
  • [26] SCREENING PATIENTS FOR RENAL-ARTERY STENOSIS - VALUE OF 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY
    LOUBEYRE, P
    REVEL, D
    GARCIA, P
    DELIGNETTE, A
    CANET, E
    CHIROSSEL, P
    GENIN, G
    AMIEL, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (04) : 847 - 852
  • [27] High resolution time-of-flight MR-angiography at 7 T exploiting VERSE saturation, compressed sensing and segmentation
    Meixner, Christian R.
    Liebig, Patrick
    Speier, Peter
    Forman, Christoph
    Hensel, Bernhard
    Schmidt, Manuel
    Saake, Marc
    Uder, Michael
    Doerfler, Arnd
    Heidemann, Robin M.
    Schmitter, Sebastian
    Nagel, Armin M.
    MAGNETIC RESONANCE IMAGING, 2019, 63 : 193 - 204
  • [28] TIME-OF-FLIGHT MR ANGIOGRAPHY OF SPINAL VASCULAR ABNORMALITIES
    BOWEN, BC
    KOCHAN, JP
    MARGOSIAN, P
    QUENCER, RM
    DONOVANPOST, MJ
    GREEN, BA
    RADIOLOGY, 1992, 185 : 122 - 122
  • [29] Simultaneous time-of-flight MR angiography and quantitative susceptibility mapping with key time-of-flight features
    De, Ashmita
    Grenier, Justin
    Wilman, Alan H.
    NMR IN BIOMEDICINE, 2024, 37 (04)
  • [30] WATER EXCITATION FISP MR-ANGIOGRAPHY OF THE EXTRACRANIAL CAROTID ARTERIES
    LITT, AW
    KNOPP, EA
    THOMASSON, DM
    RADIOLOGY, 1995, 197 : 235 - 235