AORTIC FLOW VELOCITY INDEXES DURING UPRIGHT EXERCISE - RELIABILITY AND RELATIONSHIP TO CARDIAC-OUTPUT

被引:0
|
作者
HADJIS, T [1 ]
JOBIN, J [1 ]
BOURBEAU, J [1 ]
DESGAGNES, P [1 ]
JUNEAU, L [1 ]
SAMPALIS, J [1 ]
机构
[1] HOP LAVAL,INST CARDIOL,ST FOY,PQ G1V 4G5,CANADA
关键词
AORTIC FLOW VELOCITY; EXERCISE; RELIABILITY; VENTRICULAR FUNCTION;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To determine the intra- and interobserver reproducibility of Doppler-derived ascending aortic flow velocity measurements at rest and during upright exercise of increasing intensity; and to determine the relationship between Doppler-derived measurements and cardiac output obtained by the indirect Fick carbon dioxide rebreathing method in the same conditions. SUBJECTS: Twenty young healthy adults participated in the study; eight participated in the first part and 12 in the second. DESIGN: For the intra-observer study, subjects were submitted to three workloads (50, 100 and 150 W) of 5 mins duration on two occasions, seven days apart. The intra-observer reproducibility was determined by two technicians taking the Doppler measurements within 90 s during the steady state of each workload during the first session. The relationship between cardiac output and aortic flow velocities was studied by measuring cardiac output by carbon dioxide rebreathing and flow velocities by continuous wave Doppler ultrasound simultaneously at rest as well as during the last minute of the three workloads (50, 100 and 150 W) of 5 mins duration. RESULTS: The interobserver reproducibility was very good, with r values of 0.87 for peak velocity (PV) and 0.97 for peak acceleration (PA). The intra-observer reproducibility at the seventh day interval showed r values of 0.93 for PV and 0.96 for PA for one of the technicians. PV and PA of the ascending aortic flow correlated well with cardiac output (r = 0.85 and 0.82, respectively, P<0.01). ANOVA showed that PV and PA increase proportionately with exercise intensity. CONCLUSION: PV and PA of ascending aortic flow are reproducible and reflect changes in left ventricular function during exercise.
引用
收藏
页码:100 / 104
页数:5
相关论文
共 50 条
  • [41] CARDIAC-OUTPUT IN EXERCISE BY IMPEDANCE CARDIOGRAPHY
    DUQUESNAY, MC
    STOUTE, GJ
    HUGHSON, RL
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 202 - 203
  • [42] CARDIAC-OUTPUT AS RELATED TO MUSCLE BLOOD-FLOW DURING AND FOLLOWING RHYTHMIC EXERCISE IN HUMANS
    WAALER, BA
    WALLOE, L
    WESCHE, J
    JOURNAL OF PHYSIOLOGY-LONDON, 1987, 390 : P121 - P121
  • [43] ANAEROBIC THRESHOLD AND EXERCISE CARDIAC-OUTPUT
    AUCHINCLOSS, JH
    GILBERT, R
    FEDERATION PROCEEDINGS, 1981, 40 (03) : 465 - 465
  • [44] RELIABILITY OF BIOIMPEDANCE CARDIAC-OUTPUT DETERMINATIONS IN LOW AND HIGH FLOW STATES
    KALKAT, GS
    JEYAKUMAR, P
    PURI, VK
    RAHEJA, R
    VAUGHN, SB
    CRITICAL CARE MEDICINE, 1988, 16 (04) : 430 - 430
  • [45] MECHANISM OF CARDIAC-OUTPUT INCREASE DURING DYNAMIC EXERCISE IN CARDIAC TRANSPLANT PATIENTS
    YUSUF, S
    AIKENHEAD, J
    THEODOROPOULOS, S
    DHALLA, N
    WITTES, J
    YACOUB, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (02) : A225 - A225
  • [46] VENTILATION AND CARDIAC-OUTPUT DURING THE ONSET OF EXERCISE, AND DURING VOLUNTARY HYPERVENTILATION, IN HUMANS
    CUMMIN, ARC
    IYAWE, VI
    MEHTA, N
    SAUNDERS, KB
    JOURNAL OF PHYSIOLOGY-LONDON, 1986, 370 : 567 - 583
  • [47] CARDIAC-OUTPUT DURING LABOR
    ROBSON, SC
    DUNLOP, W
    BOYS, RJ
    HUNTER, S
    BRITISH MEDICAL JOURNAL, 1987, 295 (6607): : 1169 - 1172
  • [48] EFFECTIVE PULMONARY FLOW, AORTIC FLOW AND CARDIAC-OUTPUT - INVITRO AND INVIVO COMPARISONS IN THE DOG
    FRANKS, PJ
    HOOPER, RH
    HUMPHRIES, RG
    JONES, PRM
    OCONNOR, SE
    EXPERIMENTAL PHYSIOLOGY, 1990, 75 (01) : 95 - 106
  • [49] ESTIMATION OF CARDIAC-OUTPUT BY ELECTRICAL-IMPEDANCE DURING ARM EXERCISE
    MILES, DS
    SAWKA, MN
    WILDE, SW
    DOERR, B
    FREY, MAB
    GLASER, RM
    FEDERATION PROCEEDINGS, 1980, 39 (03) : 289 - 289
  • [50] REGIONAL DISTRIBUTION OF CARDIAC-OUTPUT AT REST AND DURING EXERCISE - EFFECT OF NIFEDIPINE
    THOMSON, A
    FLETCHER, PJ
    KELLY, DT
    HARRIS, PJ
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1986, 16 (04): : 569 - 569