AORTIC FLOW VELOCITY INDEXES DURING UPRIGHT EXERCISE - RELIABILITY AND RELATIONSHIP TO CARDIAC-OUTPUT

被引:0
|
作者
HADJIS, T [1 ]
JOBIN, J [1 ]
BOURBEAU, J [1 ]
DESGAGNES, P [1 ]
JUNEAU, L [1 ]
SAMPALIS, J [1 ]
机构
[1] HOP LAVAL,INST CARDIOL,ST FOY,PQ G1V 4G5,CANADA
关键词
AORTIC FLOW VELOCITY; EXERCISE; RELIABILITY; VENTRICULAR FUNCTION;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To determine the intra- and interobserver reproducibility of Doppler-derived ascending aortic flow velocity measurements at rest and during upright exercise of increasing intensity; and to determine the relationship between Doppler-derived measurements and cardiac output obtained by the indirect Fick carbon dioxide rebreathing method in the same conditions. SUBJECTS: Twenty young healthy adults participated in the study; eight participated in the first part and 12 in the second. DESIGN: For the intra-observer study, subjects were submitted to three workloads (50, 100 and 150 W) of 5 mins duration on two occasions, seven days apart. The intra-observer reproducibility was determined by two technicians taking the Doppler measurements within 90 s during the steady state of each workload during the first session. The relationship between cardiac output and aortic flow velocities was studied by measuring cardiac output by carbon dioxide rebreathing and flow velocities by continuous wave Doppler ultrasound simultaneously at rest as well as during the last minute of the three workloads (50, 100 and 150 W) of 5 mins duration. RESULTS: The interobserver reproducibility was very good, with r values of 0.87 for peak velocity (PV) and 0.97 for peak acceleration (PA). The intra-observer reproducibility at the seventh day interval showed r values of 0.93 for PV and 0.96 for PA for one of the technicians. PV and PA of the ascending aortic flow correlated well with cardiac output (r = 0.85 and 0.82, respectively, P<0.01). ANOVA showed that PV and PA increase proportionately with exercise intensity. CONCLUSION: PV and PA of ascending aortic flow are reproducible and reflect changes in left ventricular function during exercise.
引用
收藏
页码:100 / 104
页数:5
相关论文
共 50 条
  • [31] HEATING OF MIXED BLOOD IN RELATION TO CARDIAC-OUTPUT DURING EXERCISE
    BRUNDIN, T
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1975, 35 : 63 - 63
  • [32] MEASUREMENT OF CARDIAC-OUTPUT BY ELECTRICAL IMPEDANCE AT REST AND DURING EXERCISE
    DENNISTON, JC
    MAHER, JT
    REEVES, JT
    CRUZ, JC
    CYMERMAN, A
    GROVER, RF
    JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (01) : 91 - 95
  • [33] CARDIAC-OUTPUT FROM RADIONUCLIDE VENTRICULOGRAPHY DURING REST AND EXERCISE
    MARLETTE, JM
    SHAFER, RB
    JOURNAL OF NUCLEAR MEDICINE, 1981, 22 (06) : P80 - P80
  • [34] NONINVASIVE CARDIAC-OUTPUT MONITORING DURING EXERCISE STRESS TEST
    NANNA, M
    KAWANISHI, DT
    MCKAY, CR
    RAHIMTOOLA, SH
    NIMALASURIYA, A
    CHANDRARATNA, PAN
    CANADIAN JOURNAL OF CARDIOLOGY, 1988, 4 (04) : 165 - 168
  • [35] CARDIAC-OUTPUT MONITORING BY IMPEDANCE CARDIOGRAPHY DURING TREADMILL EXERCISE
    ZHANG, Y
    QU, MG
    WEBSTER, JG
    TOMPKINS, WJ
    WARD, BA
    BASSETT, DR
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (11) : 1037 - 1042
  • [36] MEASUREMENT OF BLOOD-FLOW VELOCITY AND CARDIAC-OUTPUT IN MAN BY MRI
    LIPTON, MJ
    WEIKL, A
    MUELLER, E
    REINHARDT, ER
    CIRCULATION, 1987, 76 (04) : 161 - 161
  • [37] AN AUTOMATED, INDIRECT ASSESSMENT OF CARDIAC-OUTPUT DURING REST AND EXERCISE
    WILMORE, JH
    FARRELL, PA
    NORTON, AC
    COTE, RW
    COYLE, EF
    EWY, GA
    TEMKIN, LP
    BILLING, JE
    JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (06) : 1493 - 1497
  • [38] RELATIONSHIP BETWEEN CARDIAC-OUTPUT AND OXYGEN-UPTAKE AT THE ONSET OF EXERCISE
    YOSHIDA, T
    YAMAMOTO, K
    UDO, M
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1993, 66 (02): : 155 - 160
  • [39] RELIABILITY OF THE CARDIAC-OUTPUT MEASUREMENT WITH THE INDIRECT FICK-PRINCIPLE FOR CO2 DURING EXERCISE
    VANHERWAARDEN, CLA
    BINKHORST, RA
    FENNIS, JFM
    VANTLAAR, A
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1980, 385 (01): : 21 - 23
  • [40] CARDIAC-OUTPUT AND SKIN BLOOD-FLOW IN LEAN AND OBESE INDIVIDUALS DURING EXERCISE IN THE HEAT
    VROMAN, NB
    BUSKIRK, ER
    HODGSON, JL
    JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (01) : 69 - 74