PEAK-CAPACITY OF COLUMNS FOR SIZE-EXCLUSION CHROMATOGRAPHY

被引:11
|
作者
HAGEL, L
机构
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 591卷 / 1-2期
关键词
D O I
10.1016/0021-9673(92)80221-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The practical peak capacity of columns for size-exclusion chromatography (SEC) is related to the pore fraction (V(p)/V(t)), plate number (N) and resolution (R(s)) and may be estimated from n(SEC) almost-equal-to 1 + V(p)/V(t)) N1/2/(4R(s)). This equation yields a value of 80-90% of the maximum peak capacity, in contrast to earlier proposed equations which yield a large overestimate of the peak capacity. The practical peak capacities of columns packed with microparticulate materials is ca. 13 for completely resolved peaks, which is roughly equal to the peak capacity of columns traditionally used for SEC, the reason being the small pore volume of rigid materials and the short column lengths used. However, the maximum peak capacity is obtained with a considerably shorter separation time.
引用
收藏
页码:47 / 54
页数:8
相关论文
共 50 条
  • [41] Experimental validation of the stochastic theory of size-exclusion chromatography: Retention on single and coupled columns
    Pasti, L
    Dondi, F
    van Hulst, M
    Schoenmakers, PJ
    Martin, M
    Felinger, A
    CHROMATOGRAPHIA, 2003, 57 (Suppl 1) : S171 - S186
  • [42] Experimental validation of the stochastic theory of size-exclusion chromatography: Retention on single and coupled columns
    L. Pasti
    F. Dondi
    M. van Hulst
    P. J. Schoenmakers
    M. Martin
    A. Felinger
    Chromatographia, 2003, 57 : S171 - S186
  • [43] Stochastic theory of size exclusion chromatography: Peak shape analysis on single columns
    Felinger, A
    Pasti, L
    Dondi, F
    van Hulst, M
    Schoenmakers, PJ
    Martin, M
    ANALYTICAL CHEMISTRY, 2005, 77 (10) : 3138 - 3148
  • [44] Preparation of monolithic columns with target mesopore-size distribution for potential use in size-exclusion chromatography
    Urban, Jiri
    Jandera, Pavel
    Schoenmakers, Peter
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) : 279 - 289
  • [45] SIZE-EXCLUSION CHROMATOGRAPHY OF DNA RESTRICTION FRAGMENTS - FRAGMENT LENGTH DETERMINATIONS AND A COMPARISON WITH THE BEHAVIOR OF PROTEINS IN SIZE-EXCLUSION CHROMATOGRAPHY
    ELLEGREN, H
    LAAS, T
    JOURNAL OF CHROMATOGRAPHY, 1989, 467 (01): : 217 - 226
  • [46] THE COST OF PEAK-CAPACITY WATER
    GYSI, M
    WATER RESOURCES BULLETIN, 1981, 17 (06): : 956 - 961
  • [47] Determining persistence length by size-exclusion chromatography
    Mourey, T
    Le, K
    Bryan, T
    Zheng, SY
    Bennett, G
    POLYMER, 2005, 46 (21) : 9033 - 9042
  • [48] Size-Exclusion Chromatography for Preparative Purification of Biomolecules
    Stein, Andreas
    Heinen-Kreuzig, Anja
    Kiesewetter, Andre
    Schwarm, Sebastian
    BIOPHARM INTERNATIONAL, 2016, 29 (04) : 30 - +
  • [49] Fractionation of apple procyanidins by size-exclusion chromatography
    Yanagida, A
    Kanda, T
    Shoji, T
    Ohnishi-Kameyama, M
    Nagata, T
    JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) : 181 - 190
  • [50] Polydispersity in size-exclusion chromatography: A stochastic approach
    Sepsey, Annamaria
    Bacskay, Ivett
    Felinger, Attila
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1365 : 156 - 163