Metal Artefact Reduction by Dual-energy Computed Tomography Using Monoenergetic Extrapolation: In-vitro Determination of Optimal Monoenergetic Level with Different Metallic Implants Using a Phantom Body

被引:2
|
作者
Chan, W. C. S. [1 ]
Tsang, J. P. K. [1 ]
Wong, W. Y. [1 ]
Chu, P. Y. [1 ]
To, V. Y. K. [1 ]
Lee, C. Y. [1 ]
Yeung, T. W. [1 ]
Leung, O. C. [1 ]
Sin, N. Y. [1 ]
Li, O. C. [1 ]
Yuen, M. K. [1 ]
机构
[1] Tuen Mun Hosp, Dept Radiol, Tuen Mun, Hong Kong, Peoples R China
来源
HONG KONG JOURNAL OF RADIOLOGY | 2016年 / 19卷 / 01期
关键词
Artifacts; Metals; Prostheses and implants; Tomography; X-ray computed;
D O I
10.12809/hkjr1615356
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To identify the optimal monoenergetic level, balancing metal artefacts, and the amount of noise present for imaging of metal implants using dual-energy computed tomography (CT) and focusing on the assessment of peri-prosthetic soft tissue. Methods: Four metallic implants commonly used in the hips were placed in a phantom body: unipolar hemiprosthesis, dynamic hip screw (DHS), intra-medullary (IM) nail, and titanium insert. The unipolar hemiprosthesis was imaged at two points: the head and stem. The head of the hemiprosthesis and DHS were imaged in two axes: one axial to and one resembling the angle at its expected position in the hip with respect to the scanner. The IM nail was assessed both at the level with and without a screw inserted. A region of interest to measure the noise level of the images was first performed with different monoenergetic levels (70-170 kV with increments of 10 kV). Four monoenergetic levels were then chosen (80, 90, 105, 120 kV) for each implant and were assessed and scored (presence of least to most artefacts: score 1-4) by nine radiologists who were blinded to the monoenergetic level. A total of eight sets of images were assessed. The scores for different monoenergetic levels were compared using analysis of variance. Results: In the first part of the experiment, the images with the least amount of noise were in the range of 85-95 kV, thus we included 90 kV among the images for subsequent scoring. The mean score for different monoenergetic levels for all implants was as follows: 3.94 for 80 kV, 2.68 for 90 kV, 1.50 for 105 kV, and 1.88 for 120 kV (p < 0.001), with 105 kV having the least metal artefacts. For subgroup analysis of individual implants, 105 kV was found to produce the best quality images with a statistically significant better score for hip stem, DHS, and IM nail. 120 kV trended towards being the best monoenergetic level when imaging the hip head and the IM nail with screw where relatively more artefacts were present. 90 kV trended towards being the best monoenergetic level when imaging the titanium insert where artefacts were nearly absent. Conclusion: With regard to imaging the soft tissue around a metallic implant, the overall optimal monoenergetic level for reduction of metal artefacts using dual-energy CT is 105 kV. When more artefacts are inherently present, 120 kV trended towards being the best monoenergetic level. When artefacts are minimal, 90 kV trended towards being the optimal monoenergetic level with the least amount of noise present.
引用
收藏
页码:35 / 42
页数:8
相关论文
共 50 条
  • [41] Re: Determination of Renal Stone Composition in Phantom and Patients Using Single-Source Dual-Energy Computed Tomography Editorial Comment
    Assimos, Dean G.
    JOURNAL OF UROLOGY, 2013, 190 (02): : 570 - 570
  • [42] Improvement of image quality of laryngeal squamous cell carcinoma using noise-optimized virtual monoenergetic image and nonlinear blending image algorithms in dual-energy computed tomography
    He, Changjiu
    Liu, Jieke
    Hu, Shibei
    Qing, Haomiao
    Luo, Hongbing
    Chen, Xiaoli
    Liu, Ying
    Zhou, Peng
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2021, 43 (10): : 3125 - 3131
  • [43] Monoenergetic reconstructions and iodine density maps for visualization of coronary artery stents using 8-cm dual-layer detector spectral computed tomography: an in vitro phantom study
    Chen, Lihong
    Pan, Ning
    Hu, Bin
    Li, Yaofeng
    Dong, Shushan
    Zhou, Yinan
    Guo, Jianxin
    Yang, Jian
    Luo, Yongbai
    Jian, Zhijie
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (10) : 7671 - 7683
  • [44] Combination of Iterative Metal Artifact Reduction and Virtual Monoenergetic Reconstruction Using Split-Filter Dual-Energy CT in Patients With Dental Artifact on Head and Neck CT
    Schmidt, Alexander Marcel Alfred
    Grunz, Jan-Peter
    Petritsch, Bernhard
    Gruschwitz, Philipp
    Knarr, Jonas
    Huflage, Henner
    Bley, Thorsten Alexander
    Kosmala, Aleksander
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (04) : 716 - 727
  • [45] Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level
    An, Chansik
    Chun, Yong-Min
    Kim, Sungjun
    Lee, Young Han
    Yun, Min Jeong
    Suh, Jin-Suck
    Song, Ho-Taek
    KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (06) : 746 - 756
  • [46] Verification of the Dose Reduction Effect via Diluted Injection in Dual-Energy Computed Tomography Using a Human Blood Flow Phantom (vol 2019, 3512126, 2019)
    Tomita, Hironobu
    Shibata, Koichi
    RADIOLOGY RESEARCH AND PRACTICE, 2019, 2019
  • [47] Validation of Virtual Monochromatic Images and Effect of Body Size Obtained Using a Rapid kVp-switching Dual-energy Computed Tomography System: A Phantom Study
    Wu, Tung-Hsin
    Ting, Yun-Lung
    Hwang, Yi-Shuan
    Chui, Chen-Shou
    Lin, Cristopher K. J.
    HEALTH PHYSICS, 2022, 123 (04): : 287 - 294
  • [48] Validation of Virtual Monochromatic Images and Effect of Body Size Obtained Using a Rapid kVp-switching Dual-energy Computed Tomography System: A Phantom Study (vol 123, pg 287, 2022)
    Wu, Tung-Hsin
    Ting, Yun-Lung
    Hwang, Yi-Shuan
    Chui, Chen-Shou
    Lin, Cristopher K. J.
    HEALTH PHYSICS, 2023, 124 (05): : 427 - 427
  • [49] Reduction of Coronary Motion Artifacts in Prospectively Electrocardiography-Gated Coronary Computed Tomography Angiography Using Monochromatic Imaging at Various Energy Levels in Combination With a Motion Correction Algorithm on Single-Source Fast Tube Voltage Switching Dual-Energy Computed Tomography A Phantom Experiment
    Machida, Haruhiko
    Fukui, Rika
    Gao, Jianbo
    Tanaka, Isao
    Shen, Yun
    Suzuki, Shigeru
    Ishikawa, Takuya
    Ueno, Eiko
    INVESTIGATIVE RADIOLOGY, 2016, 51 (08) : 513 - 519
  • [50] Effects of different combinations of noise index and preset adaptive statistical iterative reconstruction Veo on the accuracy and image quality of bone mineral density measurements using fast kilovolt-switching dual-energy computed tomography: a phantom study
    Zhang, Han
    Han, Heli
    Li, Yujie
    Yang, Qiushi
    Yin, Tiantian
    Yu, Wanjiang
    Yu, Wanjiang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2025, 15 (01) : 164 - 176