Effect of stent implantation on blood pressure control in adults with coarctation of the aorta

被引:5
|
作者
van der Burg, Jennifer J. [1 ,4 ]
Warmerdam, Evangeline G. [1 ]
Krings, Gregor J. [1 ]
Meijboom, Folkert J. [1 ]
van Dijk, Arie P. [3 ]
Post, Marco C. [1 ,2 ]
Veen, Gerrit [4 ]
Voskuil, Michiel [1 ]
Sieswerda, Gertjan Tj [1 ]
机构
[1] Univ Med Ctr Utrecht, Heidelbergtaan 00, NL-3584 CX Utrecht, Netherlands
[2] St Antonius Hosp, Koekoekslaan 1, NL-3435 CM Nieuwegein, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Geer Grootepl Zuid 10, NL-6525 GA Nijmegen, Netherlands
[4] Vrije Univ Amsterdam, Med Ctr, Boelelaan 1117, NL-1081 HV Amsterdam, Netherlands
关键词
Coarctation of the aorta; Hypertension; Percutaneous intervention;
D O I
10.1016/j.carrev.2018.03.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Stenting of coarctation of the aorta (CoA) generally results in good angiographic results and a decrease in transcoarctation pressure gradient. However, effect on blood pressure control is less clear. The goal of the current retrospective analysis was to investigate the effects of CoA stenting on blood pressure control. Methods: A retrospective analysis was conducted in consecutive adult patients with a CoA who underwent a percutaneous intervention at one of the three participating hospitals. Measurements included office blood pressure, invasive peak-to-peak systolic pressure over the CoA, diameter of the intima lumen at the narrowest part of the CoA and use of medication. The follow-up data were obtained, based on the most recent examination date. Results: There were 26 native CoA and 17 recurrent CoAs (total n = 43). Seven of them underwent two procedures. Mean peak-to-peak gradient decreased from 27 mmHg to 3 mmHg (p < 0.001), and minimal diameter increased from a mean of 11 mm to 18 mm (p < 0.001). Mean systolic blood pressure decreased from 151 +/- 18 mmHg to 135 +/- 19 mmHg at first follow-up of 3.8 +/- 1.9 months and 137 +/- 22 mmHg at latest follow-up of 19.5 +/- 10.9 months (p = 0.001 and p = 0.009, compared to baseline, respectively). The total number of hypertensive patients decreased from 74% to 27% at latest follow-up. No significant change in antihypertensive medication was observed. Conclusion: A clinically significant decrease in systolic blood pressure of approximately 16 mmHg was shown after (re) intervention in CoA patients, which sustained at follow-up. This sustained decrease of blood pressure can be expected to lead to less future adverse cardiovascular events. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:944 / 950
页数:7
相关论文
共 50 条
  • [41] EFFECTS OF EXPERIMENTAL COARCTATION OF THE AORTA ON THE BLOOD PRESSURE OF SHEEP
    MAGAREY, FR
    STEHBENS, WE
    SHARP, A
    CIRCULATION RESEARCH, 1959, 7 (01) : 147 - 150
  • [42] Midterm to long-term safety and efficacy of self-expandable nitinol stent implantation for coarctation of aorta in adults
    Zeinali, Ali Mohammad Haji
    Sadeghian, Mohammad
    Qureshi, Shakeel A.
    Ghazi, Payam
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (03) : 425 - 431
  • [43] Endovascular stent implantation for coarctation of the aorta in children and young adults: intermediate follow-up results from Turkey
    Baykan, Ali
    Karagoz, Tevfik
    Celiker, Alpay
    TURKISH JOURNAL OF PEDIATRICS, 2009, 51 (02) : 116 - 119
  • [44] Stent Repair for Complex Coarctation of Aorta
    Suarez de Lezo, Jose
    Romero, Miguel
    Pan, Manuel
    Suarez de Lezo, Javier
    Segura, Jose
    Ojeda, Soledad
    Pavlovic, Djordje
    Mazuelos, Francisco
    Lopez Aguilera, Jose
    Espejo Perez, Simona
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (10) : 1368 - 1379
  • [45] Percutaneous dilation of the coarctation of aorta through balloon angioplasty and/or stent implantation - own experience
    Szkutnik, M.
    Bialkowski, J.
    EUROPEAN HEART JOURNAL, 2010, 31 : 177 - 178
  • [46] Clinical Impact of Stent Implantation for Coarctation of the Aorta with Associated Hypoplasia of the Transverse Aortic Arch
    Lu, W. H.
    Fan, Chun-Po Steve
    Chaturvedi, Rajiv
    Lee, Kyong-Jin
    Manlhiot, Cedric
    Benson, Lee
    PEDIATRIC CARDIOLOGY, 2017, 38 (05) : 1016 - 1023
  • [47] Late hemodynamic and anatomic results of balloon-expandable stent implantation for coarctation of the aorta
    Chung, AM
    Perry, SB
    Keane, JF
    Lock, JE
    CIRCULATION, 1997, 96 (08) : 3179 - 3179
  • [48] Paradoxical Hypertension after Successful Cheatham Platinum Stent Implantation in an Adolescent with Coarctation of the Aorta
    Tan, Yin Ling
    Chih, Wan-Ling
    Wang, Jou-Kou
    Chen, Chun-An
    ACTA CARDIOLOGICA SINICA, 2016, 32 (06) : 755 - 757
  • [49] Stent implantation for long-segment coarctation of aorta in infant with facial and mediastinal hemangioma
    Matitiau, A
    Birk, E
    Schonfeld, T
    Zalzstein, E
    Berant, M
    Bruckheimer, E
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (04) : 510 - 512
  • [50] Stent Implantation in Patient with Severe Coarctation of Aorta Very Close to Left Subclavian Artery
    Celebi, Ahmet
    Surucu, Murat
    Yucel, Ilker Kemal
    Bulut, Mustafa Orhan
    Demir, Ibrahim Halil
    PEDIATRIC CARDIOLOGY, 2022, 43 (08) : 1998 - 1999