TEMPERATURE RELATIONSHIP TO DISTANCE AND FLOW-RATE OF WARMED-IV FLUIDS

被引:49
|
作者
FARIES, G
JOHNSTON, C
PRUITT, KM
PLOUFF, RT
机构
[1] Department of Pediatrics (Emergency Medicine), University of Alabama, Birmingham
[2] Department of Research and Grants, University of Alabama, Birmingham
关键词
hypothermia; intravenous fluids; warmed;
D O I
10.1016/S0196-0644(05)81470-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To determine whether therapeutic benefit is obtained by administering warmed IV fluid to hypothermic children. Design: Saline at 37 C in standard IV tubing was subjected to temperature measurements within a fluid warmer and at 5, 25, 45, 65, 85, and 105 cm distally. Flow rates varied from 20 to 1,000 mL/hr. Setting: The Children's Hospital of Alabama emergency department. Type of participants: None. Interventions: None. Measurements and main results: Temperature readings were made every minute until the volume required to flush the tubing had infused. Only at rates of 750 and 1,000 mL/hr did the fluid remain warmer than 32 C more than 25 cm from the warmer. Conclusion: At flow rates usual in pediatrics, hypothermic patients must be connected to fluid warmers by lengths of IV tubing shorter than customary or practical in the ED to benefit from this treatment modality.
引用
收藏
页码:1198 / 1200
页数:3
相关论文
共 50 条
  • [31] THE EFFECTS OF VARIATION IN BODY-TEMPERATURE ON THE PREFERRED WATER TEMPERATURE AND FLOW-RATE DURING SHOWERING
    OHNAKA, T
    TOCHIHARA, Y
    WATANABE, Y
    ERGONOMICS, 1994, 37 (03) : 541 - 546
  • [32] EFFECTS OF TEMPERATURE AND FLOW-RATE ON REGIONAL BLOOD-FLOW AND METABOLISM DURING CARDIOPULMONARY BYPASS
    LAZENBY, WD
    KO, W
    ZELANO, JA
    LEBOWITZ, N
    SHIN, YT
    ISOM, OW
    KRIEGER, KH
    ANNALS OF THORACIC SURGERY, 1992, 53 (06): : 957 - 964
  • [33] MEAN VELOCITY AND THE VOLUME FLOW-RATE FOR STEADY ONE-DIMENSIONAL FLOW OF A MIXTURE OF 2 INCOMPRESSIBLE NEWTONIAN FLUIDS
    KNOPS, RJ
    STRAUGHAN, B
    QUARTERLY JOURNAL OF MECHANICS AND APPLIED MATHEMATICS, 1979, 32 (AUG): : 259 - 263
  • [34] RELATIONSHIP BETWEEN DETRUSOR PRESSURE AND URINARY FLOW-RATE IN MALES WITH AN INTRAURETHRAL PROSTATIC SPIRAL
    NIELSEN, KK
    KROMANNANDERSEN, B
    NORDLING, J
    BRITISH JOURNAL OF UROLOGY, 1989, 64 (03): : 275 - 279
  • [35] CONTRAST ENHANCEMENT REDUCES SENSITIVITY OF COLOR DOPPLER JET AREA FLOW-RATE RELATIONSHIP
    LARDO, AC
    KELLY, DL
    FAN, PH
    NANDA, NC
    CAPE, EG
    CIRCULATION, 1994, 90 (04) : 593 - 593
  • [36] THE RELATIONSHIP OF DRUG-USE TO DENTURE FUNCTION AND SALIVA FLOW-RATE IN A GERIATRIC POPULATION
    KREHER, JM
    GRASER, GN
    HANDELMAN, SL
    JOURNAL OF PROSTHETIC DENTISTRY, 1987, 57 (05): : 631 - 638
  • [37] RELATIONSHIP OF URINE FLOW-RATE (V) AND PROSTAGLANDIN-E EXCRETION (PGE) - ANALYSIS OF FACTORS INFLUENCING THIS RELATIONSHIP
    LARIOS, O
    EPSTEIN, M
    LIFSCHITZ, MD
    KIDNEY INTERNATIONAL, 1984, 25 (01) : 333 - 333
  • [38] DRIPPING FAUCET APPARATUS WITH TEMPERATURE AND HIGH-RESOLUTION TIMING AND FLOW-RATE CONTROLS
    WU, XM
    TEKLE, E
    SCHELLY, ZA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (12): : 3779 - 3782
  • [39] FBG sensors combining target with cantilever beam for simultaneous measurement of Flow-rate/temperature
    Yu, Da-Kuan
    Jia, Zhen-An
    Qiao, Xue-Guang
    Zhang, Qian
    Liu, Qin-Peng
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2010, 21 (05): : 710 - 713
  • [40] Assessment of the complementarity of temperature and flow-rate for response normalisation of aerosol-based detectors
    Khandagale, Manish M.
    Hilder, Emily F.
    Shellie, Robert A.
    Haddad, Paul R.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1356 : 180 - 187