Heart defibrillation requires exposure of most of the myocardium to a pulsed electric field or potential gradient. The global trend in external defibrillation is undoubtedly the biphasic waveform. If we analyze the defibrillator's international market, we can find around 25 manufacturers and around 15 different biphasic waveforms as it has not yet been established what the optimal waveform for external defibrillation is. Preliminarily, we call it Optimal Transthoracic Defibrillation Waveform, that restores the myocardium normal pumping function with minimal energy applied to the patient. The current state-of-the-art in cardiac electrophysiology allows us, in our point of view, to hope that we may determine what the best way to deliver defibrillation shocks is. There is now scientific consensus that the simple exponential model of cellular membrane potential is a reasonable tool to establish optimal defibrillation parameters, but not with respect to the main parameter of the model, the membrane time constant. In this paper we propose a sketch of a line of research to achieve this goal that is divided into seven main stages: 1. Improving the electrical model of cellular membrane incorporating nonlinearity due to electroporation. 2. Using the improved model to select one (or more) typical waveforms to be evaluated experimentally. 3. Implementing a purely experimental stage to verify empirically the in-vivo waveforms in isolated animal hearts. 4. Extrapolating results to the chest of the animal used. 5. Experimentally adjusting the parameters of optimal external waveform in these animals. 6. Using a mathematical model of the human chest and test animal chest to define preliminarily the optimum external waveform for humans. 7. Clinical validation of the results obtained.
引用
收藏
页码:202 / 208
页数:7
相关论文
共 50 条
  • [31] Optimal design of waveform digitisers for both energy resolution and pulse shape discrimination
    Cang, Jirong
    Xue, Tao
    Zeng, Ming
    Zeng, Zhi
    Ma, Hao
    Cheng, Jianping
    Liu, Yinong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 888 : 96 - 102
  • [32] The effect of biphasic waveform tilt in transvenous atrial defibrillation
    Sra, J
    Bremner, S
    Krum, D
    Dhala, A
    Blanck, Z
    Deshpande, S
    Biehl, M
    Li, HG
    Jazayeri, MR
    Akhtar, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (06): : 1613 - 1618
  • [33] Sawtooth first phase biphasic defibrillation waveform: A comparison with standard waveform in clinical devices
    Yamanouchi, Y
    Brewer, JE
    Mowrey, KA
    Kroll, MW
    Donohoo, AM
    Wilkoff, BL
    Tchou, PJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (05) : 517 - 528
  • [34] Improved defibrillation efficacy with an ascending ramp waveform in humans
    Shorofsky, SR
    Rashba, E
    Havel, W
    Belk, P
    Degroot, P
    Swerdlow, C
    Gold, MR
    HEART RHYTHM, 2005, 2 (04) : 388 - 394
  • [35] Improved defibrillation efficacy in humans with an ascending ramp waveform
    Shorofsky, SR
    Swerdlow, CD
    Havel, WJ
    Belk, PA
    DeGroot, PJ
    Gold, MR
    Rashba, E
    CIRCULATION, 2003, 108 (17) : 325 - 325
  • [36] Optimal Waveform Design Oriented Toward Cognitive Radar in Fractional Fourier Domain
    Zhang, Xiaowen
    Wang, Kaizhi
    Gao, Yesheng
    Liu, Xingzhao
    2016 IEEE RADAR CONFERENCE (RADARCONF), 2016, : 1004 - 1008
  • [37] Comparison of rectilinear biphasic waveform with biphasic truncated exponential waveform in a pediatric defibrillation model
    Wang, Jinglan
    Tang, Wanchun
    Brewer, James E.
    Freeman, Gary
    Chang, Yun-Te
    Weil, Max Harry
    CRITICAL CARE MEDICINE, 2007, 35 (08) : 1961 - 1965
  • [38] The Gurvich waveform has lower defibrillation threshold than the rectilinear waveform and the truncated exponential waveform in the rabbit heart
    Qu, FJ
    Zarubin, F
    Wollenzier, B
    Nikolski, VP
    Efimov, IR
    CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2005, 83 (02) : 152 - 160
  • [39] OPTIMAL TRUNCATION OF DEFIBRILLATION PULSES
    IRNICH, W
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (04): : 673 - 688
  • [40] A framework of current based defibrillation improves defibrillation efficacy of biphasic truncated exponential waveform in rabbits
    Li, Weiming
    Li, Jingru
    Wei, Liang
    Wang, Jianjie
    Peng, Li
    Wang, Juan
    Yin, Changlin
    Li, Yongqin
    SCIENTIFIC REPORTS, 2021, 11 (01)