A COMPARISON OF STONE DAMAGE CAUSED BY DIFFERENT MODES OF SHOCK-WAVE GENERATION

被引:0
|
作者
CHUONG, CJC
ZHONG, P
PREMINGER, GM
机构
[1] UNIV TEXAS,SW MED CTR,DIV MINERAL METAB,DALLAS,TX 75230
[2] UNIV TEXAS,JOINT BIOMED ENGN PROGRAM,ARLINGTON,TX 76019
[3] UNIV TEXAS,SW MED CTR,DIV UROL,DALLAS,TX 75230
来源
JOURNAL OF UROLOGY | 1992年 / 148卷 / 01期
关键词
LITHOTRIPSY; CALCULI;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
A standard stone phantom was used to compare stone damage after extracorporeal shock wave administration from electrohydraulic, electromagnetic and piezoelectric lithotripters. For each machine, a low and high shock wave intensity setting was chosen: 18 & 24 kV for electrohydraulic; 16 & 19 kV for electromagnetic; power levels 1 and 4 for piezoelectric. The shock wave was focused either at the front (surface facing the wave source) or back surface of the stone and 50, 100, 200 or 400 shocks were delivered to different stone groups. Effects of varying physical properties in the stone phantom were also investigated. Stone damage was described in terms of volume loss and both depth and width of the resulting damage crater. At the lower intensity settings, all three machines produced stone volume loss which was linearly related to the number of shock delivered. At higher intensity settings, volume loss increased rapidly as the number of shocks increased. With the same number of shocks, stone volume loss was greatest with the electrohydraulic machine, followed by electromagnetic and piezoelectric lithotripters for both low and high intensity settings. Damage craters from the piezoelectric device were narrow and deep; those from the electromagnetic machine were of the shape of a right angle circular cone; whereas those from the electrohydraulic lithotripter were shallow and wide. At the high intensity settings, damage from the piezoelectric and electrohydraulic lithotripters appeared to depend upon the position of the focal point with a higher volume loss when the shock waves were targeted at the front surface of the stone. For the electromagnetic device, a higher volume loss was found when we positioned the focal point at the back surface of the stone phantom. Stone phantoms with lower mechanical strength and acoustic impedance were more easily damaged than those with higher values. Finally, a computer regression model was developed to express volume loss in terms of the intensity setting, focal position and number of shocks for each lithotripter.
引用
收藏
页码:200 / 205
页数:6
相关论文
共 50 条
  • [21] EXTRACORPOREAL SHOCK-WAVE LITHOTRIPSY FOR RENAL STONE DISEASE IN CHILDREN
    BRAREN, V
    SOUTHERN MEDICAL JOURNAL, 1986, 79 (09) : 82 - 82
  • [22] DETONATION CAUSED BY THE FALL OF THE SHOCK-WAVE ONTO THE WALL
    VYSK, ND
    VESTNIK MOSKOVSKOGO UNIVERSITETA SERIYA 1 MATEMATIKA MEKHANIKA, 1983, (01): : 55 - 59
  • [23] THE RELATION OF STONE COMPOSITION TO EXTRACORPOREAL SHOCK-WAVE LITHOTRIPSY (ESWL)
    SCHULDES, H
    VONWALDTHAUSEN, W
    BEHRENDT, U
    DROSSEL, HC
    NAGEL, R
    UROLOGICAL RESEARCH, 1986, 14 (02): : 98 - 98
  • [24] STONE GEOMETRY AND STRUCTURE DEPENDENCE ON EXTRACORPOREAL SHOCK-WAVE LITHOTRIPSY
    PITTOMVILS, G
    VANDEURSEN, H
    HELLEMANS, J
    DEMEULENAERE, R
    MATURA, E
    BOVING, R
    BAERT, L
    JOURNAL OF ENDOUROLOGY, 1993, 7 (05) : 357 - 362
  • [25] EXTRACORPOREAL SHOCK-WAVE LITHOTRYPSY USING ULTRASONIC STONE LOCALIZATION
    MARTIN, X
    DUBERNARD, JM
    GELET, A
    JOURNAL OF UROLOGY, 1986, 135 (04): : A159 - A159
  • [26] THE RELATION OF STONE COMPOSITION TO EXTRACORPOREAL SHOCK-WAVE LITHOTRIPSIE (ESWL)
    SCHULDES, H
    VONWALDTHAUSEN, W
    BEHRENDT, U
    DROSSEL, HC
    NAGEL, R
    AKTUELLE UROLOGIE, 1986, 17 (04) : 186 - 188
  • [27] URETERAL STONE MANIPULATION PRECEDING EXTRACORPOREAL SHOCK-WAVE LITHOTRIPSY
    LINGEMAN, JE
    NEWMAN, DM
    MERTZ, JHO
    MOSBAUGH, PG
    STEELE, RE
    KNAPP, PM
    KULB, TB
    JOURNAL OF UROLOGY, 1986, 135 (04): : A153 - A153
  • [28] EXTRACORPOREAL SHOCK-WAVE LITHOTRIPSY IN SCHISTOSOMA PATIENTS WITH STONE FORMATIONS
    ALOTAIBI, KE
    SAID, MT
    KOURAH, MA
    ABOMELHA, MS
    SAUDI MEDICAL JOURNAL, 1991, 12 (04) : 298 - 300
  • [29] Comparison of Different Kinetic and Continuum Models Applied to the Shock-Wave Structure Problem
    Kudryavtsev, A. N.
    Shershnev, A. A.
    Ivanov, M. S.
    RAREFIED GAS DYNAMICS, 2009, 1084 : 507 - 512
  • [30] Improvement of stone fragmentation during shock-wave lithotripsy using a combined EH/PEAA shock-wave generator -: In vitro experiments
    Xi, XF
    Zhong, P
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03): : 457 - 467