A sensitive assay using inductively coupled plasma atomic emission spectroscopy (ICP-AES) has been applied to the measurement of trace elements in diaspirin cross-linked hemoglobin (DCLHb) solutions. Calcium, magnesium, zinc and iron were the only elements detected at greater than background levels. Ag, Al, As, B, Ba, Bi, Cd, Co, Cr, Cu, Mn, Mo, Pb, Sb, Se, Si, Sr, Ti, and V were present at concentrations either equal to the acid blanks or were not detected. Detection of non-heme iron (not incorporated into the hemoglobin porphyrin ring) in a 10 g/dL hemoglobin solution required the development of a special protocol. In this protocol a chelator, DTPA, was added to hemoglobin solutions to complex with both free and non-specifically bound non-heme iron. The resulting iron:DTPA complexes were separated from the hemoglobin molecules by ultrafiltration and the ultra-filtrate analyzed by ICP-AES. A modification of this assay in which the DTPA was omitted was used to measure the free non-heme iron in solution. Typical concentrations of chelatable (free and non-specifically bound) and solution (free) non-heme iron in DCLHb production lots at the completion of manufacture were 0.5-1.0 ppm and 0.1-0.3 ppm, respectively.
引用
收藏
页码:453 / 456
页数:4
相关论文
共 50 条
  • [21] RESUSCITATION WITH DIASPIRIN CROSS-LINKED HEMOGLOBIN IN A PIG MODEL OF HEMORRHAGIC-SHOCK
    DUNLAP, E
    FARRELL, L
    NIGRO, C
    ESTEP, T
    MARCHAND, G
    BURHOP, K
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND IMMOBILIZATION BIOTECHNOLOGY, 1995, 23 (01): : 39 - 61
  • [22] Hemoglobin and methemoglobin concentrations after large-dose infusions of diaspirin cross-linked hemoglobin
    O'Hara, JF
    Colburn, WA
    Tetzlaff, JE
    Novick, AC
    Angermeier, KW
    Schubert, A
    ANESTHESIA AND ANALGESIA, 2001, 92 (01): : 44 - 48
  • [23] DIASPIRIN CROSS-LINKED HEMOGLOBIN (DCLHB(TM)) ATTENUATES BACTERIAL TRANSLOCATION IN RATS
    SCHULTZ, SC
    POWELL, CC
    BERNARD, E
    MALCOLM, DS
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 1995, 23 (06): : 647 - 664
  • [24] CARDIOVASCULAR CHANGES FOLLOWING HEMORRHAGE IN RATS ARE REVERSED BY DIASPIRIN CROSS-LINKED HEMOGLOBIN
    SEN, AP
    SHARMA, AC
    GULATI, A
    FASEB JOURNAL, 1995, 9 (04): : A937 - A937
  • [25] Effect of perioperative administration of diaspirin cross-linked hemoglobin on indices of organ function
    Schubert, A
    Bedocs, NM
    OHara, JF
    Tetzlaff, JE
    Marks, KE
    Novick, AC
    ANESTHESIOLOGY, 1997, 87 (03) : A220 - A220
  • [26] DIASPIRIN CROSS-LINKED HEMOGLOBIN - EVALUATION OF EFFECTS ON THE MICROCIRCULATION OF STRIATED-MUSCLE
    NOLTE, D
    BOTZLAR, A
    HECHT, R
    CSAPO, C
    MENGER, MD
    MESSMER, K
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 1994, 22 (03): : 587 - 592
  • [27] PRAZOSIN BLOCKS THE PRESSOR BUT NOT THE REGIONAL CIRCULATORY EFFECTS OF DIASPIRIN CROSS-LINKED HEMOGLOBIN
    GULATI, A
    SHARMA, AC
    LIFE SCIENCES, 1994, 55 (02) : 121 - 130
  • [28] ROLE OF NO MECHANISM IN CARDIOVASCULAR EFFECTS OF DIASPIRIN CROSS-LINKED HEMOGLOBIN IN ANESTHETIZED RATS
    SHARMA, AC
    SINGH, G
    GULATI, A
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (04): : H1379 - H1388
  • [29] THE EFFICACY OF DIASPIRIN CROSS-LINKED HEMOGLOBIN SOLUTION RESUSCITATION IN A MODEL OF UNCONTROLLED HEMORRHAGE
    SCHULTZ, SC
    POWELL, CC
    BURRIS, DG
    NGUYEN, H
    JAFFIN, J
    MALCOLM, DS
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1994, 37 (03): : 408 - 412
  • [30] Diaspirin cross-linked hemoglobin improves mucosal perfusion in the ileum of septic rats
    Sielenkämper, AW
    Eichelbrönner, O
    Martin, CM
    Madorin, SW
    Chin-Yee, IH
    Sibbald, WJ
    CRITICAL CARE MEDICINE, 2000, 28 (03) : 782 - 787