MULTISTORY BASE-ISOLATED BUILDINGS UNDER A HARMONIC GROUND MOTION .2. SENSITIVITY ANALYSIS

被引:19
|
作者
FAN, FG [1 ]
AHMADI, G [1 ]
TADJBAKHSH, IG [1 ]
机构
[1] RENSSELAER POLYTECH INST,DEPT CIVIL ENGN,TROY,NY 12181
关键词
D O I
10.1016/0029-5493(90)90267-2
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A series of sensitivity analyses for multi-story base-isolated structures subject to a harmonic ground excitation is carried out. Several base isolation and energy dissipation devices are considered. The effects of variations in properties of structures and base-isolation systems on the peak responses are studied. For a range of natural frequency, friction coefficient, and damping of the isolator, the peak responses are evaluated. The sensitivity of the base-isolated structure to variations in the amplitude and the frequency of ground excitation is also studied. Particular attention is given to the effects of long-period excitations. The study shows that the peak structural responses for base isolators with a frictional element are less sensitive to variations in intensity and frequency of ground excitation when compared with non-frictional systems. Furthermore, the performances of frictional isolators are insensitive to small variations in friction coefficient and its velocity-dependence. © 1990.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 50 条
  • [31] Optimal cost-effective topology of column bearings for reducing vertical acceleration demands in multistory base-isolated buildings
    Unal, Mehmet
    Warn, Gordon P.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2014, 43 (08): : 1107 - 1127
  • [32] Spatial seismic modeling of base-isolated buildings pounding against moat walls: effects of ground motion directionality and mass eccentricity
    Mavronicola, Eftychia A.
    Polycarpou, Panayiotis C.
    Komodromos, Petros
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2017, 46 (07): : 1161 - 1179
  • [33] Integrated design optimization of base-isolated concrete buildings under spectrum loading
    X. K. Zou
    Structural and Multidisciplinary Optimization, 2008, 36
  • [34] Limitations of height-to-width ratio for base-isolated buildings under earthquake
    Li, Hong-Nan
    Wu, Xiang-Xiang
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2006, 15 (03): : 277 - 287
  • [35] Displacement response analysis of base-isolated buildings subjected to near-fault ground motions with velocity pulse
    He, Qiumei
    Li, Xiaojun
    Yang, Yu
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2014, 22 (01): : 1 - 13
  • [36] Analysis for Displacement Response Characteristics of Complex Multi-layer Base-Isolated Structure under Near-Field Ground Motion
    Fang D.
    Du Y.
    Liu C.
    Deng Y.
    Liu, Chengqing (lcqjd@swjtu.edu.cn), 1600, Science Press (55): : 158 - 166and192
  • [37] Influence of ground motion duration and isolation bearings on the seismic response of base-isolated bridges
    Hassan, Afraa Labiba
    Billah, A. H. M. Muntasir
    ENGINEERING STRUCTURES, 2020, 222
  • [38] Correlation between ground motion intensity indexes and displacement responses of a base-isolated structure under pulse-type ground motions
    Wang Y.
    Yu J.
    Du Y.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (10): : 262 - 268
  • [39] Seismic Response of Base-Isolated Structures underMulti-component Ground Motion Excitation
    Jiang Yicheng Tang Jiaxiang School of Civil Engineering
    Journal of China University of Geosciences, 2001, (01) : 90 - 94
  • [40] Seismic analysis of base-isolated liquid storage tanks on the layered ground
    Kim, MK
    Lim, YM
    Cho, SY
    Lee, K
    PROCEEDINGS OF US-KOREA WORKSHOP ON NEW FRONTIER IN INFRASTRUCTURAL/SEISMIC ENGINEERING, 2000, : 259 - 272