DETECTION OF PYONEPHROSIS USING DUAL-ISOTOPE IMAGING TECHNIQUE

被引:0
|
作者
TRAN, MH [1 ]
SAKOW, NK [1 ]
DOREY, JH [1 ]
机构
[1] UNIV LOUISVILLE HOSP,DEPT DIAGNOST RADIOL,LOUISVILLE,KY
关键词
D O I
10.1097/00003072-199402000-00022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dual isotope imaging with Ga-67 and Tc-99m mercaptoacetyltriglycine (MAG3) can assist in identifying pyonephrosis. A 70-year-old man with retroperitoneal fibrosis developed fever of unknown origin following bilateral ureteral stent placement. Ga-67 scan reveals focal, intense activity in the left flank. Tc-99m MAG3 renogram shows a focus of photon deficiency in the superior pole of the left kidney. This photopenic lesion corresponds with the intense Ga-67 activity. The pyonephrosis was diagnosed and confirmed with fine-needle aspiration. This diagnosis was not clear from the CT scan, which demonstrated persistent hydronephrosis of the left kidney. Subsequently, the patient was found to have a duplicated left collecting system. The upper pelvis had not been stented and became infected secondary to lack of drainage.
引用
收藏
页码:161 / 162
页数:2
相关论文
共 50 条
  • [21] A DUAL-ISOTOPE TECHNIQUE FOR DETERMINATION OF INVIVO KETONE-BODY KINETICS
    MILES, JM
    SCHWENK, WF
    MCCLEAN, KL
    HAYMOND, MW
    AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (02): : E185 - E191
  • [22] Application of dual-isotope technique in nuclear cardiology and its scatter correction
    Li, Wengang
    Chen, Shaoliang
    He Jishu/Nuclear Techniques, 2002, 25 (05):
  • [23] Vitamin A equivalency and apparent absorption of β-carotene in ileostomy subjects using a dual-isotope dilution technique
    Van Loo-Bouwman, Carolien A.
    Naber, Ton H. J.
    van Breemen, Richard B.
    Zhu, Dongwei
    Dicke, Heleen
    Siebelink, Els
    Hulshof, Paul J. M.
    Russel, Frans G. M.
    Schaafsma, Gertjan
    West, Clive E.
    BRITISH JOURNAL OF NUTRITION, 2010, 103 (12) : 1836 - 1843
  • [24] RADIONUCLIDE SIMULTANEOUS DUAL-ISOTOPE STRESS MYOCARDIAL PERFUSION STUDY USING THE 3 WINDOW TECHNIQUE
    YANG, DC
    RAGASA, E
    GOULD, L
    HUANG, M
    REDDY, CVR
    SAUL, B
    SCHIFTER, D
    RAINALDI, D
    FELD, C
    TANK, RA
    LEE, SY
    GIOVANNIELLO, J
    CLINICAL NUCLEAR MEDICINE, 1993, 18 (10) : 852 - 857
  • [25] Simultaneous Dual-Isotope SPECT Imaging Using Independent Component Analysis Based on Wavelet Transformation
    Yang, Bang-Hung
    Wang, Shyh-Jen
    Chou, Yuan-Hwa
    Chen, Jyh-Cheng
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, VOLS 1-9, 2009, : 4462 - +
  • [26] Dual-isotope imaging method for Actinium-225 and Bismuth-213 using alpha imaging detector
    Kim, Jong-Guk
    Kim, Guna
    Lee, Hyun Su
    Kim, Byoungsoo
    Lim, Il-Han
    Kim, Kwangil
    Lee, Kyochul
    APPLIED RADIATION AND ISOTOPES, 2024, 206
  • [27] Imaging of gene expression in live pancreatic islet cell lines using dual-isotope SPECT
    Tai, Joo Ho
    Nguyen, Binh
    Wells, R. Glenn
    Kovacs, Michael S.
    McGirr, Rebecca
    Prato, Frank S.
    Morgan, Timothy G.
    Dhanvantari, Savita
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (01) : 94 - 102
  • [28] SENSITIVITY OF DUAL-ISOTOPE SPECT MYOCARDIAL PERFUSION IMAGING FOR DETECTION OF SPECIFIC ATHEROSCLEROTIC LESIONS - A COMPARISON TO ANGIOGRAPHY
    STOBBE, DE
    MILNE, N
    SANFORD, I
    KARLSBERG, RP
    KRANE, MJ
    LYONS, KP
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P65 - P65
  • [29] Dual-isotope myocardial perfusion SPECT imaging: Past, present, and future
    Sharir, Tali
    Slomka, Piotr
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (06) : 2024 - 2028
  • [30] Return of dual-isotope SPECT myocardial perfusion imaging? Not so fast ...
    Henzlova, Milena J.
    Duvall, W. Lane