THE EFFECT OF HENNA PASTE ON OXYGEN-SATURATION READING OBTAINED BY PULSE OXIMETRY

被引:0
|
作者
ALMAJED, SA [1 ]
HARAKATI, MS [1 ]
机构
[1] KING SAUD UNIV, KING KHALID UNIV HOSP, COLL MED, DEPT MED 38, RIYADH 11472, SAUDI ARABIA
来源
TROPICAL AND GEOGRAPHICAL MEDICINE | 1994年 / 46卷 / 01期
关键词
HENNA; PULSE OXIMETRY; OXYGEN SATURATION; SAUDI ARABIA;
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A controlled study was designed to examine the effect of red and black henna on the measurement of oxygen saturation by pulse oximetry. Fifty adult normal female volunteers had their left thumb coloured with red henna (40) or black henna (10). The uncoloured right thumb was used as a control. All measurements were done under room temperature, and the same pulse oximeter was used in ah volunteers. In the red henna group there was no difference on oximetry reading between right and left thumb. In contrast, the thumb coloured with black henna gave no reading when compared to the uncoloured right thumb, On the basis of this study, pulse oximetry is not limited by red henna while black henna has a potential of causing major error in the measurement of oxygen saturation by pulse oximetry, In these cases we recommend to use ear oximetry for accurate measurement of oxygen saturation.
引用
收藏
页码:38 / 39
页数:2
相关论文
共 50 条
  • [31] INTRAPARTUM FETAL PULSE OXIMETRY - FETAL OXYGEN-SATURATION TRENDS DURING LABOR AND RELATION TO DELIVERY OUTCOME
    DILDY, GA
    VANDENBERG, PP
    KATZ, M
    CLARK, SL
    JONGSMA, HW
    NIJHUIS, JG
    LOUCKS, CA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (03) : 679 - 684
  • [32] PULSE OXIMETRY FAILS TO ACCURATELY DETECT LOW-LEVELS OF ARTERIAL HEMOGLOBIN OXYGEN-SATURATION IN DOGS
    SIDI, A
    RUSH, W
    GRAVENSTEIN, N
    RUIZ, B
    PAULUS, DA
    DAVIS, RF
    JOURNAL OF CLINICAL MONITORING, 1987, 3 (04): : 257 - 262
  • [33] OXYGEN-SATURATION MONITORING IN EXPERIMENTAL SURGERY - A COMPARISON OF PULSE OXIMETRY AND ARTERIAL BLOOD-GAS MEASUREMENT
    VENDER, JR
    HAND, CM
    SEDOR, D
    TABOR, SL
    BLACK, P
    LABORATORY ANIMAL SCIENCE, 1995, 45 (02): : 211 - 215
  • [34] PULSE OXIMETRY USED FOR DOCUMENTING OXYGEN-SATURATION AND RIGHT-TO-LEFT SHUNTING IMMEDIATELY AFTER BIRTH
    MEIERSTAUSS, P
    BUCHER, HU
    HURLIMANN, R
    KONIG, V
    HUCH, R
    EUROPEAN JOURNAL OF PEDIATRICS, 1990, 149 (12) : 851 - 855
  • [35] PULSE OXIMETRY IN SICK PREMATURE-INFANTS AND THE EFFECTS OF PHOTOTHERAPY AND RADIANT WARMERS ON THE OXYGEN-SATURATION READOUT
    ZUBROW, AB
    HENDERSON, GW
    IMAIZUMI, SO
    PLEASURE, JR
    AMERICAN JOURNAL OF PERINATOLOGY, 1990, 7 (01) : 75 - 78
  • [36] Pulse Oximetry Overestimates Oxygen Saturation in COPD
    Amalakanti, Sridhar
    Pentakota, Mohan Rao
    RESPIRATORY CARE, 2016, 61 (04) : 423 - 427
  • [37] Oxygen Saturation in Pulse Oximetry in Hemoglobin Anomalies
    Zur, B.
    Bagci, S.
    Ludwig, M.
    Stoffel-Wagner, B.
    KLINISCHE PADIATRIE, 2012, 224 (04): : 259 - 265
  • [38] The effect of shellac nail polish on measurement of oxygen saturation by pulse oximetry
    Loy, M.
    Riddell, L.
    ANAESTHESIA, 2014, 69 : 42 - 42
  • [39] OXYGEN-SATURATION BY PULSE OXIMETRY IN HEALTHY INFANTS AT AN ALTITUDE OF 1610-M (5280 FT) - WHAT IS NORMAL
    THILO, EH
    PARKMOORE, B
    BERMAN, ER
    CARSON, BS
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1991, 145 (10): : 1137 - 1140
  • [40] METHYLENE-BLUE AND INDOCYANINE GREEN ARTIFACTUALLY LOWER PULSE OXIMETRY READINGS OF OXYGEN-SATURATION - STUDIES IN DOGS
    SIDI, A
    PAULUS, DA
    RUSH, W
    GRAVENSTEIN, N
    DAVIS, RF
    JOURNAL OF CLINICAL MONITORING, 1987, 3 (04): : 249 - 256