A COMPARISON BETWEEN FIBER LENGTH MEASUREMENT METHODS

被引:0
|
作者
BENTLEY, RG
SCUDAMORE, P
JACK, JS
机构
关键词
FIBER LENGTH; MEASUREMENT; MEASURING INSTRUMENTS; BAUER-MCNETT CLASSIFIERS;
D O I
暂无
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
A comparison between Kajaani FS-200 and Bauer-McNett fibre length measurements of several different pulps was conducted. Good linear relationships were found to exist between the measurements obtained by the two methods but they varied according to the type of pulp employed. The precision of measurement of the two methods proved to be comparable, generally to within +/-3 to 4%.
引用
收藏
页码:41 / 45
页数:5
相关论文
共 50 条
  • [21] A novel fiber length measurement technique for discontinuous fiber-reinforced composites: A comparative study with existing methods
    Goris, Sebastian
    Back, Teresa
    Yanev, Angel
    Brands, Dave
    Drummer, Dietmar
    Osswald, Tim A.
    POLYMER COMPOSITES, 2018, 39 (11) : 4058 - 4070
  • [22] Relationship between motion artifacts and fiber length of a flocked electrode in electrocardiogram measurement
    Takeshita, Toshihiro
    Yoshida, Manabu
    Kobayashi, Takeshi
    Takei, Yusuke
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 370
  • [23] Fiber length measurement by image processing
    Ikiz, Y
    Rust, JP
    Jasper, WJ
    Trussell, HJ
    TEXTILE RESEARCH JOURNAL, 2001, 71 (10) : 905 - 910
  • [24] Next generation fiber length measurement
    Tiikkaja, Esa
    Sopenlehto, Taina
    Palpu Chongi Gisul/Journal of Korea Technical Association of the Pulp and Paper Industry, 2000, 32 (05): : 54 - 59
  • [25] Leg length discrepancy in total hip arthroplasty: comparison of two methods of measurement
    Arkan S. Sayed-Noor
    Anders Hugo
    Göran O. Sjödén
    Per Wretenberg
    International Orthopaedics, 2009, 33 : 1189 - 1193
  • [26] Leg length discrepancy in total hip arthroplasty: comparison of two methods of measurement
    Sayed-Noor, Arkan S.
    Hugo, Anders
    Sjoden, Goran O.
    Wretenberg, Per
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (05) : 1189 - 1193
  • [27] Measurement of limb length inequality - Comparison of clinical methods with orthoradiography in 190 children
    Lampe, HIH
    Swierstra, BA
    Diepstraten, AFM
    ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (03): : 242 - 244
  • [28] METHODS FOR MEASURING FIBER LENGTH DISTRIBUTION
    TALLANT, JD
    PITTMAN, RA
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1969, 8 (01): : 174 - &
  • [29] METHODS FOR MEASURING FIBER LENGTH DISTRIBUTION
    WRONSKI, J
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1967, 6 (04): : 595 - &
  • [30] Comparison of different methods for telomere length measurement in whole blood and blood cell subsets: Recommendations for telomere length measurement in hematological diseases
    Behrens, Yvonne Lisa
    Thomay, Kathrin
    Hagedorn, Maike
    Ebersold, Juliane
    Henrich, Lea
    Nustede, Rainer
    Schlegelberger, Brigitte
    Goehring, Gudrun
    GENES CHROMOSOMES & CANCER, 2017, 56 (09): : 700 - 708