Data from the analytical performance of the Abaxis Piccolo Xpress point of care analyzer in whole blood, serum, and plasma

被引:1
|
作者
Murata, Kazunori [1 ]
Glaser, Laurel [2 ]
Nardiello, Mary [3 ]
Ramanathan, Lakshmi V. [1 ]
Carlow, Dean C. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Lab Med, 1275 York Ave, New York, NY 10065 USA
[2] Univ Penn, Dept Pathol & Lab Med, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Childrens Hosp Philadelphia, Dept Pathol & Lab Med, Philadelphia, PA 19104 USA
来源
DATA IN BRIEF | 2018年 / 16卷
关键词
Clinical chemistry; Point-of care testing;
D O I
10.1016/j.dib.2017.11.006
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The objective of this study was to examine the analytical performance of 14 comprehensive metabolic panel analytes on the Abaxis Piccolo Xpress (R) Point of Care analyzer in serum, plasma, and whole blood. A method comparison was performed on all three specimen types intended for use on the Piccolo Xpress (R) : serum, heparinized plasma, and whole blood. This data is also presented in Murata et al. (2015) [1]. This article includes the actual Bland-Altman bias plots of the difference in results obtained for analytes in the comprehensive metabolic panel from the Abaxis Piccolo Xpress and the comparison instrument, the Ortho Vitros. (C) 2017 Published by Elsevier Inc.
引用
收藏
页码:81 / 89
页数:9
相关论文
共 50 条
  • [1] Analytical performance of the Abaxis Piccolo Xpress® point of care analyzer in whole blood, serum, and plasma
    Murata, Kazunori
    Glaser, Laurel
    Nardiello, Mary
    Richardson, Shaun
    Ramanathan, Lakshmi V.
    Carlow, Dean C.
    [J]. CLINICAL BIOCHEMISTRY, 2015, 48 (18) : 1344 - 1346
  • [2] Point of care testing of liver an kidney functions with Abaxis Piccolo Xpress® chemistry analyzer
    Aksel, Yasar
    Boon-Falleur, Laurent
    Guillaume, Benoit
    [J]. ACTA CLINICA BELGICA, 2017, 72 : 8 - 9
  • [3] Performance Evaluation of the Piccolo xpress Point-of-care Chemistry Analyzer
    Park, Hyunwoong
    Ko, Dae-Hyun
    Kim, Jin Q.
    Song, Sang Hoon
    [J]. KOREAN JOURNAL OF LABORATORY MEDICINE, 2009, 29 (05): : 430 - 438
  • [4] OUTCOMES IN POINT OF CARE TESTING PICCOLO XPRESS® ANALYZER VERSUS CENTRAL LABORATORIES
    Ghansiam, Joshua
    Miller, Mark Daniel
    Galmin, Gregory
    Hernandez, Gabriella
    Escobar, Melisa
    Hawthorne, Keianna Lameria
    Nguyen, Anna Hien Thao
    Kurtz, Daniel Joseph, Jr.
    Saravanan, Kavitharini
    Neff, Guy W.
    [J]. HEPATOLOGY, 2021, 74 : 974A - 975A
  • [5] Innotrac Aio! a point-of-care or a routine analyzer? Analytical performance and plasma/whole blood comparison
    Altinier, Sara
    Zaninotto, Martina
    Mion, Monica Maria
    Plebani, Mario
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (10) : 1278 - 1282
  • [6] Evaluation of the Piccolo Xpress chemistry analyzer for point of care testing of plasma liver function markers, electrolytes and metabolites
    Schnabl, K. L.
    Tarek, M.
    Cursio, C.
    Yip, P. M.
    [J]. CLINICAL BIOCHEMISTRY, 2008, 41 (14-15) : 1284 - 1285
  • [7] Evaluation of the Lipid Panel on the Abaxis Piccolo Xpress to Determine Its Potential as a Point-of-Care Instrument in a Nonlaboratory Setting
    Simpson, Paul
    Jolly, Lisa
    Tirimacco, Rosy
    Gill, Jan
    Tideman, Philip
    [J]. POINT OF CARE, 2010, 9 (01): : 32 - 35
  • [8] Reliability of the point-of care analyzer "StatStrip® Xpress™" for measurement of fetal blood lactate
    Iorizzo, Linda
    Persson, Kristina E. M.
    Kristensen, Karl H.
    Wiberg, Nana
    [J]. CLINICA CHIMICA ACTA, 2019, 495 : 88 - 93
  • [9] Analytical performance of Immunotrac AIO analyzer cardiac markers on plasma and whole blood samples
    Altinier, S
    Zaninotto, M
    Mion, M
    Plebani, M
    [J]. CLINICA CHIMICA ACTA, 2005, 355 : S395 - S395
  • [10] Comparison of a point-of-care glucometer and an automated biochemical analyzer to measure glucose concentrations in whole blood, serum, and plasma from porcine blood samples.
    Gohlke, M. K.
    Nunnelley, W. Z.
    Brandebourg, T. D.
    [J]. JOURNAL OF ANIMAL SCIENCE, 2017, 95 : 157 - 158