Simulation study of nasotracheal and orotracheal fiberoptic intubation with the Aintree Intubation Catheter

被引:1
|
作者
Ueki, Ryusuke [1 ]
Komasawa, Nobuyasu [2 ]
Hirose, Munetaka [1 ]
Kaminoh, Yoshiroh [3 ]
机构
[1] Hyogo Coll Med, Dept Anesthesiol & Pain Med, Mukogawa Cho 1-1, Nishinomiya, Hyogo 6638501, Japan
[2] Osaka Med Coll, Dept Anesthesiol, Osaka, Japan
[3] Social Insurance Kinan Hosp, Div Anesthesiol, Wakayama, Japan
来源
ACUTE MEDICINE & SURGERY | 2015年 / 2卷 / 04期
关键词
Aintree intubation catheter (AIC); fiber-optic intubation; nasotracheal intubation; orotracheal intubation; simulation;
D O I
10.1002/ams2.126
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimFiber-optic tracheal intubation is an essential technique to secure the airway for difficult airway and cervical cord injury victims. However, there is an anxiety about the vocal cord passage of tracheal tubes because of the potential of collision with the surroundings of the vocal cords. This study aimed to examine the utility of the Aintree Intubation Catheter in nasotracheal and orotracheal intubation. MethodsParticipants were 21 anesthesiologists with more than 2 years of experience in clinical anesthesia. Participants attempted fiber-optic tracheal intubation through the oral or nasal cavity with or without the Aintree Intubation Catheter in random order. The success rate of tracheal intubation, intubation time, and collision with the glottis were recorded. Participants also evaluated the subjective difficulty of the entire intubation process and passing the tracheal tube through the glottis using a Visual Analogue Scale. ResultsThere were no significant differences in intubation time or Visual Analogue Scale scores for passing the tracheal tube through the glottis between nasal and oral intubation, regardless of the use of the Aintree Intubation Catheter. However, the catheter significantly reduced the number of collisions with the glottis in both routes (nasal, P=0.026; oral, P=0.017). ConclusionOur findings that the Aintree Intubation Catheter is effective in reducing collisions with the glottis during nasal and oral fiber-optic intubation suggest that Aintree Intubation Catheter use may reduce the risk of mechanical injury related to airway obstruction.
引用
收藏
页码:263 / 266
页数:4
相关论文
共 50 条
  • [31] Logistic Regression for Mouth (orotracheal) or Nose (nasotracheal) Endotracheal Intubation
    Nair, Rekha
    Singh, Tripty
    Nayar, Ravi
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON POWER, CONTROL, SIGNALS AND INSTRUMENTATION ENGINEERING (ICPCSI), 2017, : 2026 - 2031
  • [32] Aintree catheter™-aided intubation via the supraglottic airway
    Clark, R.
    Cunningham, V.
    [J]. ANAESTHESIA, 2013, 68 (08) : 883 - 883
  • [33] NOSOCOMIAL SINUSITIS IN VENTILATED PATIENTS - NASOTRACHEAL VERSUS OROTRACHEAL INTUBATION
    BACH, A
    BOEHRER, H
    SCHMIDT, H
    GEISS, HK
    [J]. ANAESTHESIA, 1992, 47 (04) : 335 - 339
  • [34] BENEFITS OF OROTRACHEAL AND NASOTRACHEAL INTUBATION IN NEONATES REQUIRING VENTILATORY ASSISTANCE
    MCMILLAN, DD
    RADEMAKER, AW
    BUCHAN, KA
    REID, A
    MACHIN, G
    SAUVE, RS
    [J]. PEDIATRICS, 1986, 77 (01) : 39 - 44
  • [35] Orotracheal to nasotracheal intubation exchange in pediatric patients with a difficult airway
    Liu, He Ping
    Xue, Fu Shan
    Guo, Xin Ling
    Liao, Xu
    [J]. PEDIATRIC ANESTHESIA, 2010, 20 (04) : 377 - 379
  • [36] PROPOFOL AS THE SOLE AGENT FOR INTUBATION - COMPARISON OF THE OROTRACHEAL AND NASOTRACHEAL ROUTES
    VIVIAND, X
    GUIDONATTALI, C
    LACARELLE, B
    DURBEC, O
    MOUILLAC, F
    MARTIN, C
    FRANCOIS, G
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 82 - 82
  • [37] FACILITATION OF FIBEROPTIC OROTRACHEAL INTUBATION WITH A FLEXIBLE TRACHEAL TUBE
    BRULL, SJ
    WIKLUND, R
    FERRIS, C
    CONNELLY, NR
    EHRENWERTH, J
    SILVERMAN, DG
    [J]. ANESTHESIA AND ANALGESIA, 1994, 78 (04): : 746 - 748
  • [38] EFFECT OF FENTANYL ON THE CIRCULATORY RESPONSES TO OROTRACHEAL FIBEROPTIC INTUBATION
    SMITH, JE
    KING, MJ
    YANNY, HF
    POTTINGER, KA
    POMIRSKA, MB
    [J]. ANAESTHESIA, 1992, 47 (01) : 20 - 23
  • [39] A technique for securing the Aintree Intubation Catheter™ to a flexible bronchoscope
    Phipps, Sarah
    Malpas, Gemma
    Hung, Orlando
    [J]. CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2018, 65 (03): : 329 - 330
  • [40] Awake fiberoptic nasotracheal intubation in patient with previous pharyngoplasty
    Tse, Jockey
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2016, 117