AN INTEGRATED CONCEPT OF AUTOMATED INSTRUMENT CONTROL, QUALITY ASSURANCE AND DATA REPORTING FOR DIOXIN/FURAN ANALYSIS

被引:2
|
作者
SCHUBERT, R
PESCH, R
PFAFF, H
SCHROEDER, E
机构
[1] Finnigan MAT GmbH, W-2800 Bremen 14
关键词
AUTOMATION; HRGC/HRMS; QUANTITATION; QUALITY CONTROL ASSURANCE; REPORTING;
D O I
10.1016/0045-6535(93)90272-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
TACO (TArget Compound analysis software) is a newly designed software package that is used as common user interface for QUANTUM, a new high resolution target compound analyzer. It coordinates instrument control of the high resolution mass spectrometer, the gas chromatograph and the autosampler. It takes care about data acquisition, data evaluation and quantitation according to predefined methods. These methods also determine quality control parameters from the mass spectrometer and from the data evaluation. System performance parameters can be checked against method dependent limits and may stop batch processing via feedback control. TACO finally generates reports that integrate text and graphics in a flexible user defined format.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [31] Technical quality assurance and quality control for medical laboratories: a review and proposal of a new concept to obtain integrated and validated QA/QC plans
    van Rossum, Huub H.
    [J]. CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 2022, 59 (08) : 586 - 600
  • [32] Automated quality assurance routines for fMRI data applied to a multicenter study
    Stöcker, T
    Schneider, F
    Klein, M
    Habel, U
    Kellermann, T
    Zilles, K
    Shah, NJ
    [J]. HUMAN BRAIN MAPPING, 2005, 25 (02) : 237 - 246
  • [33] The Geriatric Minimum Data Set (Gemidas) as a quality assurance instrument in clinical geriatrics
    Borchelt, M
    Vogel, W
    Steinhagen-Thiessen, E
    [J]. ZEITSCHRIFT FUR GERONTOLOGIE UND GERIATRIE, 1999, 32 (01): : 11 - 23
  • [34] Quality assurance of automated gamma-ray spectrometric analysis
    Glavic-Cindro, D
    Korun, M
    Vodenik, B
    [J]. APPLIED RADIATION AND ISOTOPES, 2000, 53 (1-2) : 237 - 241
  • [35] A Software Tool for Automated Analysis of CT Quality Assurance Phantoms
    Grimes, J.
    Leng, S.
    McCollough, C.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 558 - 558
  • [36] Automated quality assurance analysis: WRF-A case study
    Collins, John
    Farrimond, Brian
    Anderson, Mark
    Owens, Darryl
    Bayliss, Darryl
    Gill, David
    [J]. Journal of Software, 2013, 8 (09) : 2177 - 2184
  • [37] Protocols for the assurance of microarray data quality and process control
    Burgoon, LD
    Eckel-Passow, JE
    Gennings, C
    Boverhof, DR
    Burt, JW
    Fong, CJ
    Zacharewski, TR
    [J]. NUCLEIC ACIDS RESEARCH, 2005, 33 (19) : 1 - 11
  • [38] Quality assurance and quality control reporting in untargeted metabolic phenotyping: mQACC recommendations for analytical quality management
    Kirwan, Jennifer A.
    Gika, Helen
    Beger, Richard D.
    Bearden, Dan
    Dunn, Warwick B.
    Goodacre, Royston
    Theodoridis, Georgios
    Witting, Michael
    Yu, Li-Rong
    Wilson, Ian D.
    [J]. METABOLOMICS, 2022, 18 (09)
  • [39] Quality assurance and quality control reporting in untargeted metabolic phenotyping: mQACC recommendations for analytical quality management
    Jennifer A. Kirwan
    Helen Gika
    Richard D. Beger
    Dan Bearden
    Warwick B. Dunn
    Royston Goodacre
    Georgios Theodoridis
    Michael Witting
    Li-Rong Yu
    Ian D. Wilson
    [J]. Metabolomics, 18
  • [40] A validity-based approach to quality control and assurance of automated scoring
    Bejar, Isaac
    [J]. ASSESSMENT IN EDUCATION-PRINCIPLES POLICY & PRACTICE, 2011, 18 (03) : 319 - 341