A SUBCUTANEOUS LEAD ARRAY FOR IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS

被引:25
|
作者
JORDAENS, L
VERTONGEN, P
VANBELLEGHEM, Y
机构
[1] Department of Cardiology, University Hospital, Ghent
来源
关键词
COMPLICATIONS; IMPLANTABLE CARDIOVERTER DEFIBRILLATORS; TRANSVENOUS DEFIBRILLATION; VENTRICULAR FIBRILLATION;
D O I
10.1111/j.1540-8159.1993.tb01739.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two patients received an implantable cardioverter defibrillator with the combination of a transvenous lead and a subcutaneous lead array with three branches. This approach allowed us to find low defibrillation thresholds in both patients (less-than-or-equal-to 10 and less-than-or-equal-to 15 joules [J], respectively), which was impossible with a transvenous catheter. In a third patient, a crinkled subcutaneous patch was replaced by an array. The defibrillation threshold with the array was less-than-or-equal-to 20 J, as opposed to > 24 J with the patch. No surgical problems occurred. The subcutaneous array is a technical improvement for the therapy with implantable defibrillators, when a single catheter system is not sufficient to ensure a safety margin for defibrillation, or when surgical or postsurgical problems occur with a subcutaneous patch.
引用
收藏
页码:1429 / 1433
页数:5
相关论文
共 50 条
  • [21] Deactivation of implantable cardioverter-defibrillators
    Wan, Darryl
    Chakrabarti, Santabhanu
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2021, 193 (23) : E852 - E852
  • [22] IMPLANTABLE TRANSVENOUS CARDIOVERTER-DEFIBRILLATORS
    BARDY, GH
    HOFER, B
    JOHNSON, G
    KUDENCHUK, PJ
    POOLE, JE
    DOLACK, GL
    GLEVA, M
    MITCHELL, R
    KELSO, D
    [J]. CIRCULATION, 1993, 87 (04) : 1152 - 1168
  • [23] Implantable cardioverter-defibrillators in children
    Blom, Nico A.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 : S32 - S34
  • [24] Driving and implantable cardioverter-defibrillators
    Grubb, Blair P.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (23) : 2241 - 2242
  • [25] Implantable cardioverter-defibrillators - Reply
    McClellan, MB
    Tunis, SR
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (19): : 2025 - 2025
  • [26] The Deactivation of Implantable Cardioverter-Defibrillators
    Carlsson, Jorg
    Paul, Norbert W.
    Dann, Matthias
    Neuzner, Joerg
    Pfeiffer, Dietrich
    [J]. DEUTSCHES ARZTEBLATT INTERNATIONAL, 2012, 109 (33-34): : 535 - U14
  • [27] Implantable cardioverter-defibrillators and complications
    Sinclair, CT
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (07): : 734 - 734
  • [28] MORTALITY AND IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    MOWER, MM
    [J]. CIRCULATION, 1993, 88 (01) : 332 - 332
  • [29] Implantable cardioverter-defibrillators in children
    DeWitt, Elizabeth S.
    Abrams, Dominic J.
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 2015, 100 (03) : 265 - 270
  • [30] Automatic implantable cardioverter-defibrillators
    Smith, WM
    Ideker, RE
    [J]. ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 1999, 1 : 331 - 346