IN-VITRO EVALUATION OF 3-DIMENSIONAL ULTRASONOGRAPHY IN VOLUME ESTIMATION OF ABDOMINAL ORGANS

被引:102
|
作者
GILJA, OH [1 ]
THUNE, N [1 ]
MATRE, K [1 ]
HAUSKEN, T [1 ]
ODEGAARD, S [1 ]
BERSTAD, A [1 ]
机构
[1] CHRISTIAN MICHELSEN RES, BERGEN, NORWAY
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1994年 / 20卷 / 02期
关键词
ABDOMINAL ORGANS; KIDNEY; STOMACH; 3-DIMENSIONAL RECONSTRUCTION; VOLUME MEASUREMENTS; ULTRASONIC IMAGING; ULTRASONOGRAPHY;
D O I
10.1016/0301-5629(94)90080-9
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this study was to evaluate the accuracy and precision of a three-dimensional (3D) ultrasound system in volume estimation of abdominal organs in vitro. A mechanical sector scanner coupled to a stepping motor recorded images of porcine stomach and kidneys. The transducer was tilted through 88-degrees yielding 81 frames, and volume estimation was performed digitally after interactive manual contour indication and organ reconstruction in 3 dimensions. This 3D system showed good correlation (r = 0.998) between estimated and true volumes. Volume estimation of stomach and kidneys using 3.25 MHz probe demonstrated limits of agreement of 0.877 to 1.146 and 1.007 to 1.125, respectively, depicting estimated volumes as a proportion of true volumes in 95% of the examinations. Intra- and interobserver variation of the tracing procedure revealed low values. We conclude that this 3D ultrasound system performs high accuracy and precision in volume estimation.
引用
收藏
页码:157 / 165
页数:9
相关论文
共 50 条
  • [21] 3-DIMENSIONAL ECHOCARDIOGRAPHIC MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN-VITRO - COMPARISON WITH 2-DIMENSIONAL ECHOCARDIOGRAPHY AND CINEVENTRICULOGRAPHY
    SAPIN, PM
    SCHROEDER, KD
    SMITH, MD
    DEMARIA, AN
    KING, DL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) : 1530 - 1537
  • [22] GERMINAL MATRIX MICROVASCULAR MATURATION - 3-DIMENSIONAL IN-VITRO STUDIES
    MENT, LR
    STEWART, WB
    MADRI, JA
    ANNALS OF NEUROLOGY, 1995, 38 (03) : 502 - 502
  • [23] OPTIMIZATION TECHNIQUE FOR THE CALCULATION OF IN-VITRO 3-DIMENSIONAL VERTEBRAL MOTION
    SHEA, M
    EDWARDS, WT
    WHITE, AA
    HAYES, WC
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (03): : 366 - 369
  • [24] A 3-DIMENSIONAL IN-VITRO MODEL FOR THE STUDY OF OCULAR CYTOTOXICITY AND IRRITANCY
    DONNELLY, T
    DECKER, D
    STEMP, M
    RHEINS, L
    LOGEMANN, P
    TOXICOLOGY IN VITRO, 1994, 8 (04) : 631 - 633
  • [25] ULTRASONIC 3-DIMENSIONAL IMAGING AND VOLUME - AN INVITRO EVALUATION
    BRINKLEY, JF
    MCCALLUM, WD
    POPP, RL
    AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (04): : 897 - 897
  • [26] Estimation of myometrial and placental volume and vascularization by 3-dimensional ultrasound
    More, O. M.
    Granger, G. G.
    Barranger, E. B.
    Cabrol, D. C.
    Tsatsaris, V. T.
    PLACENTA, 2008, 29 (08) : A17 - A17
  • [27] ESTIMATION OF MAXILLARY ALVEOLAR CLEFT VOLUME BY 3-DIMENSIONAL CT
    BRADRICK, JP
    SMITH, AS
    OHMAN, JC
    INDRESANO, AT
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) : 994 - 996
  • [28] VOLUME ESTIMATION OF THE GASTRIC ANTRUM AND THE GALLBLADDER IN PATIENTS WITH NONULCER DYSPEPSIA AND EROSIVE PREPYLORIC CHANGES, USING 3-DIMENSIONAL ULTRASONOGRAPHY
    HAUSKEN, T
    THUNE, N
    MATRE, K
    GILJA, OH
    ODEGAARD, S
    BERSTAD, A
    NEUROGASTROENTEROLOGY AND MOTILITY, 1994, 6 (04): : 263 - 270
  • [29] 3-DIMENSIONAL ENDOMETRIAL VOLUME AS A PREDICTOR OF PREGNANCY IN IN-VITRO FERTILISATION CYCLES OVER 2-DIMENSIONAL ENDOMETRIAL THICKNESS.
    Gupta, M.
    Singh, N.
    Malhotra, N.
    Mahey, R.
    Vanamail, P.
    Pant, S.
    FERTILITY AND STERILITY, 2014, 102 (03) : E312 - E312
  • [30] OPTICAL HOLOGRAPHIC 3-DIMENSIONAL ULTRASONOGRAPHY
    BAUM, G
    STROKE, GW
    SCIENCE, 1975, 189 (4207) : 994 - 995