INVIVO AND INVITRO CONSIDERATIONS OF CORROSION TESTING

被引:12
|
作者
BROWN, SA [1 ]
MERRITT, K [1 ]
机构
[1] DARTMOUTH COLL,HANOVER,NH 03755
关键词
BIOLOGICAL MATERIALS - Blood;
D O I
10.3109/10731198109117601
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vitro experiments were conducted in which the fretting corrosion rate of stainless steel plates and screws in 0. 9% saline was compared with the rate in solutions of 10% calf serum in saline. The results demonstrated a ten-fold decrease in the fretting corrosion rate with the addition of serum to saline. However, it also demonstrated that the lower concentration of nickel in the serum solutions was more biologically active than the higher concentration in saline when the solutions were used to skin-test rabbits made allergic to nickel by injection.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [41] A COMPARISON OF INVITRO AND INVIVO METHODS FOR TESTING TOXICITY OF SURFACTANTS TO THE CORNEAL EPITHELIUM
    OSGOOD, TB
    UBELS, JL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 998 - 998
  • [42] CORROSION OF COPPER, NICKEL, AND GOLD DENTAL CASTING ALLOYS - AN INVITRO AND INVIVO STUDY
    JOHANSSON, BI
    LUCAS, LC
    LEMONS, JE
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH-APPLIED BIOMATERIALS, 1989, 23 (A3): : 349 - 361
  • [43] RABBIT ANTI-HUMAN THYMOCYTE GLOBULIN (RAHTG) - INVITRO AND INVIVO TESTING
    THOMAS, J
    MILLINGTON, M
    VOLK, M
    THOMAS, F
    HUME, D
    TRANSPLANTATION PROCEEDINGS, 1974, 6 (04) : 395 - 398
  • [44] ANTIBIOTIC-SENSITIVITY TESTING - CORRELATIONS BETWEEN INVITRO TESTS AND INVIVO SITUATIONS
    DEVRIESE, LA
    DUTTA, GN
    ANNALES DE RECHERCHES VETERINAIRES, 1981, 12 (01): : 41 - 46
  • [45] A NOVEL-APPROACH TO THE SEARCH FOR INVITRO ALTERNATIVES TO INVIVO EYE IRRITANCY TESTING
    MUIR, CK
    FLOWER, C
    VANABBE, NJ
    TOXICOLOGY LETTERS, 1983, 18 (1-2) : 1 - 5
  • [46] INVITRO AND INVIVO ANALYSIS OF ANODIZED TANTALUM CAPACITIVE ELECTRODES - CORROSION RESPONSE, PHYSIOLOGY, AND HISTOLOGY
    JOHNSON, PF
    BERNSTEIN, JJ
    HUNTER, G
    DAWSON, WW
    HENCH, LL
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1977, 11 (05): : 637 - 656
  • [47] INVITRO INVIVO CORRELATION, A TIME SCALING PROBLEM - BASIC TECHNIQUES FOR TESTING EQUIVALENCE
    BROCKMEIER, D
    VOEGELE, D
    VONHATTINGBERG, HM
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1983, 33-1 (04): : 598 - 601
  • [48] INVIVO AND INVITRO STUDIES OF THE STRESS-CORROSION CRACKING BEHAVIOR OF SURGICAL IMPLANT ALLOYS
    BUNDY, KJ
    MAREK, M
    HOCHMAN, RF
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (03): : 467 - 487
  • [49] Corrosion testing needs and considerations for additively manufactured materials in nuclear reactors
    Jokisaari, Andrea M.
    Chen, Yiren
    Copeland-Johnson, Trishelle
    Hartmann, Thomas
    Joshi, Vineet
    van Rooyen, Isabella
    Song, Rongjie
    Wierschke, Jonathan
    PROGRESS IN NUCLEAR ENERGY, 2024, 174
  • [50] ANTIOXIDANTS INVITRO AND INVIVO